摘要
Steam generation from intermediate petroleum products of different hydrocarbon processes ensures zero waste in oil and gas industries. The generated steam is again used for production of refinery final products. Although, zero waste increases refinery margin, there is downside associated with tube failure in utility boiler. Fire side corrosion occurred on economizer tube and failure was systematically analysed. A series of characterization techniques were conducted to find out the root cause of failure. Visual inspection, mechanical characterization, plant data collection, morphology investigation of scales using SEM, elemental analysis using EDX, and microstructural analysis were employed. Sulfur content was precisely determined on fire side scale deposits. Steam side feed water and steam products were analysed as well. Characterization of fire side deposits revealed iron oxide scales with severe sulfur concentration as well. The results revealed that failure was primarily owing to acid dew point corrosion and sulfur came from intermediate fuel oil (IFO). The failure mechanisms were discussed and good engineering practices were put forward to combat and mitigate acid dew point corrosion.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Boiler Stack Economizer Tube Failure
    Haase, Ryan J.
    Hanke, Larry D.
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2013, 13 (05) : 513 - 520
  • [2] Modeling of the boiler economizer
    Trojan, Marcin
    Granda, Mariusz
    [J]. XI INTERNATIONAL CONFERENCE ON COMPUTATIONAL HEAT, MASS AND MOMENTUM TRANSFER (ICCHMT 2018), 2018, 240
  • [3] Constructal design for a boiler economizer
    Tang, Wei
    Feng, Huijun
    Chen, Lingen
    Xie, Zhuojun
    Shi, Junchao
    [J]. ENERGY, 2021, 223
  • [4] Economizer replacement restores boiler efficiency
    Elsner, RW
    Harth, GH
    Mayer, EH
    Schaper, DP
    [J]. POWER ENGINEERING, 1998, 102 (03) : 36 - +
  • [5] Effect of wall temperature of tubes on fly ash erosion of the economizer in a coal-fired utility boiler
    Xu, KY
    Wang, J
    Ma, QL
    Dong, W
    Zhao, XP
    Shi, QG
    [J]. ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1747 - 1750
  • [6] DESIGN AND COMPUTATIONAL VALIDATION OF IN-LINE BARE TUBE ECONOMIZER FOR A 210 MW PULVERIZED COAL FIRED BOILER
    Dhamangaonkar, P. R.
    Deshmukh, Abhishek
    Pansare, Santosh
    Nandgaonkar, M. R.
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 6A, 2014,
  • [7] Failure analysis of boiler economizer tubes at power house
    Pal, Urbi
    Kishore, Kaushal
    Mukhopadhyay, Suman
    Mukhopadhyay, Goutam
    Bhattacharya, Sandip
    [J]. ENGINEERING FAILURE ANALYSIS, 2019, 104 : 1203 - 1210
  • [8] Flow induced vibration of recovery boiler economizer tubes
    LeBel, M
    Reis, V
    [J]. 2001 INTERNATIONAL CHEMICAL RECOVERY CONFERENCE: CHANGING RECOVERY TECHNOLOGY TO MEET THE CHALLENGES OF THE PULP AND PAPER INDUSTRY, 2001, : 329 - 336
  • [9] A Multizone Model of an Economizer in a 600 MW Boiler Unit
    Wang Jizhou
    Zhang Yanping
    Li Yu
    Huang Shuhong
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2012, 134 (04):
  • [10] RESIDUAL LIFE ASSESSMENT OF A CRACKED BOILER ECONOMIZER HEADER
    COADE, RW
    FORD, PR
    [J]. METALS FORUM, 1984, 7 (04): : 243 - 250