Development of an immunochromatographic assay for rapid and quantitative detection of clenbuterol in swine urine

被引:85
|
作者
Li, Chaohui [1 ,2 ]
Luo, Wei [2 ]
Xu, Hengyi [1 ]
Zhang, Qin [3 ]
Xu, Hong [4 ]
Aguilar, Zoraida P. [4 ]
Lai, Weihua [1 ]
Wei, Hua [1 ,2 ]
Xiong, Yonghua [1 ,2 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Peoples R China
[2] Nanchang Univ, Sino German Joint Res Inst, Nanchang 330047, Peoples R China
[3] Shanghai Huguo Sci Instrument Co Ltd, Shanghai 200237, Peoples R China
[4] Ocean NanoTech LLC, Springdale, AR 72764 USA
关键词
Immunochromatographic assay; Rapid and quantitative detection; Clenbuterol; Swine urine; LINKED-IMMUNOSORBENT-ASSAY; LATERAL FLOW IMMUNOASSAY; ENZYME-IMMUNOASSAY; MASS-SPECTROMETRY; BETA-AGONISTS; TEST STRIP; SENSITIVE DETECTION; CHICKEN MUSCLE; BOVINE LIVER; WHOLE-BLOOD;
D O I
10.1016/j.foodcont.2013.06.021
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A lateral flow strip test was developed for quantitative detection of clenbuterol (CLE) in swine urine in a 10 min total assay time. This new quantitative system for CLE was developed based on the concept of using the ratio of the optical densities (ODs) of the test line (AT) to that of the control line (A(C)) to offset the inherent heterogeneity of lateral flow test strips (LFTSAT/AC) and the effect of sample matrix. Various parameters such as immunoreaction time, the concentration of analyte, reaction temperature and pH of the reactions, as well as the ionic strength were optimized in urine samples. The assay kinetics based on the immunological reactions indicated achievement of constant signal within 5-10 min of incubation depending upon the CLE concentration. Using the optimized parameters, the linear range for the quantitative detection of CLE using the LFTSAT/AC was between 100 pg/mL and 2500 pg/mL over a 10 min total assay time. The CLE LFTSAT/AC showed a half maximal inhibitory concentration (IC50) of 460+/-60 pg/mL (n = 5) and a reliable coefficient of correlation (R-2 = 0.996). The CLE test strip exhibited insignificant cross-reaction (Cr) to mabuterol, isoproterenol, salbutamol, terbutaline, brombuterol, ractopamine and bambuterol. The limit of detection (LOD) for swine urine was 220 pg/mL, and recoveries for spiked sample were 102.35% +/- 7.66% at 500 pg/mL, 95.07% +/- 7.14% at 1000 pg/mL and 100.65% +/- 10.21% at 1500 pg/mL, respectively. The intra-and inter-assay precision at 500-1500 pg/mL CLE concentrations showed coefficients of variation (CVs) at <11%. This rapid quantitative LFTSAT/AC system for CLE in spiked urine samples exhibited a coefficient of correlation with traditional ELISA at 0.97 (N = 50). Furthermore, 96% of 90 samples gave a percent recovery of 100 +/- 30%. These results indicated that the 10-min colloidal gold-based LFTSAT/AC system is adaptive, sensitive, reproducible, and comparable to traditional ELISA method with the added advantage of being easy to use, inexpensive, and requires non-skilled personnel. The LFTSAT/AC holds promise for field use an on-site detection of CLE in swine urine samples. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:725 / 732
页数:8
相关论文
共 50 条
  • [1] Improvement of the stability of immunochromatographic assay for the quantitative detection of clenbuterol in swine urine
    Peng, Tao
    Yang, Wan-chun
    Lai, Wei-Hua
    Xiong, Yong-Hua
    Wei, Hua
    Zhang, Jinsheng
    [J]. ANALYTICAL METHODS, 2014, 6 (18) : 7394 - 7398
  • [2] Integrated immunochromatographic assay for qualitative and quantitative detection of clenbuterol
    Chen, Yuan
    Huang, Zhen
    Hu, Song
    Zhang, Ganggang
    Peng, Juan
    Xia, Jun
    Lai, Weihua
    [J]. ANALYTICAL BIOCHEMISTRY, 2019, 577 : 45 - 51
  • [3] Sample Preincubation Strategy for Sensitive and Quantitative Detection of Clenbuterol in Swine Urine Using a Fluorescent Microsphere-Based Immunochromatographic Assay
    Deng, Sheng L.
    Shan, Shan
    Xu, Chao L.
    Liu, Dao F.
    Xiong, Yong H.
    Wei, Hua
    Lai, Wei H.
    [J]. JOURNAL OF FOOD PROTECTION, 2014, 77 (11) : 1998 - 2003
  • [4] Development of an immunochromatographic assay for rapid detection of clorprenaline in pig urine
    Jiang, Wei
    Zeng, Lu
    Liu, Liqiang
    Song, Shanshan
    Kuang, Hua
    [J]. FOOD AND AGRICULTURAL IMMUNOLOGY, 2018, 29 (01) : 536 - 547
  • [5] Development of a Nano-Gold Capillary Immunochromatographic Assay for Rapid and Semi-Quantitative Detection of Clenbuterol Residues
    Xueli Qu
    Hong Lin
    Shuyuan Du
    Jianxin Sui
    Xinlei Zhang
    Limin Cao
    [J]. Food Analytical Methods, 2016, 9 : 2531 - 2540
  • [6] Development of a Nano-Gold Capillary Immunochromatographic Assay for Rapid and Semi-Quantitative Detection of Clenbuterol Residues
    Qu, Xueli
    Lin, Hong
    Du, Shuyuan
    Sui, Jianxin
    Zhang, Xinlei
    Cao, Limin
    [J]. FOOD ANALYTICAL METHODS, 2016, 9 (09) : 2531 - 2540
  • [7] Development of an immunochromatographic assay for rapid detection of 1-Aminohydantoin in urine specimens
    Xu, Yi Ping
    Liu, Li Qiang
    Li, Qiu Shen
    Peng, Chi Fang
    Chen, Wei
    Xu, Chuan Lai
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (03) : 308 - 314
  • [8] Evaluation of a rapid immunochromatographic assay for detection of Legionella pneumophila in urine
    Moore, N
    Gentile, D
    [J]. LEGIONELLA, 2002, : 211 - 212
  • [9] Lateral-Flow Assay for Rapid Quantitative Detection of Clorprenaline Residue in Swine Urine
    Peng, Tao
    Zhang, Fu S.
    Yang, Wan C.
    Li, Dong X.
    Chen, Yuan
    Xiong, Yong H.
    Wei, Hua
    Lai, Wei H.
    [J]. JOURNAL OF FOOD PROTECTION, 2014, 77 (10) : 1824 - 1829
  • [10] Development of an Ultrasensitive Immunochromatographic Assay (ICA) Strip for the Rapid Detection of Phenylethanolamine A in Urine and Pork Samples
    Li Junhua
    Li Chunsheng
    Wu Meng
    Zhang Yan
    Ma Xiaofei
    Cheng Hua
    Yan Jinghui
    [J]. JOURNAL OF FOOD SCIENCE, 2015, 80 (04) : T894 - T899