Indoor exploratory analysis of gaseous pollutants and respirable particulate matter at residential homes of Delhi, India

被引:33
|
作者
Kulshreshtha, Priyanka [1 ]
Khare, Mukesh [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Delhi 110016, India
关键词
Indoor outdoor ratios; Biomass fuels; Seasonal variation; Respirable particulate matter; AIR-POLLUTION; DEVELOPING-COUNTRIES; CARBON-MONOXIDE; EXPOSURE ASSESSMENT; BIOMASS COMBUSTION; PERSONAL EXPOSURE; RURAL ENERGY; FUEL USE; OUTDOOR; URBAN;
D O I
10.5094/APR.2011.038
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Biomass fuels are frequently used as a source of domestic energy in developing countries that may cause indoor air pollution. This study presents indoor and outdoor combustion pollutants (CO and NOx) and respirable particulate matter-RSPM (PM10, PM2.5 and PM1.0) concentrations measured during winter and summer seasons in 8 homes in Delhi, India. CO2 concentrations have been used to measure the outdoor airflow rates. This study further investigates variations in indoor/outdoor concentrations of the pollutants as a result of various activities in commercial (Site I) and institutional areas (Site II). The institutional area has been considered as the control site. Monitoring has been conducted at each site for 3 days in a week in both summer and winter seasons to investigate the diurnal variations of pollutant concentrations. Then, the I/O ratios have also been estimated. The correlation analysis of indoor pollutant concentrations with outdoor concentrations has been carried out. Winter/Summer (W/S) ratios have also been calculated and a two tailed t-test has been used to determine whether the winter and summer mean concentrations are significantly higher. The I/O ratios for PM10, PM2.5 and PM1.0 at Site I homes, in winter season, have been found to be 1.43 +/- 0.84, 2.72 +/- 1.94 and 3.21 +/- 2.39, respectively. I/O ratio for CO has been found to be 2.99 +/- 2.19 in winters at Site I. The linear regression analysis results have revealed that usage of biomass fuels for cooking has increased the concentrations of RSPM and CO indoors, considerably in winter. W/S ratios for RSPM have also been found to be higher than 1.0 at almost all the homes indicating that the concentration of RSPM is higher in winter season. Regression analysis results indicated that the major sources for RSPM and CO exist indoors and that is principally, cooking using the biomass as fuels and also cleaning of homes manually, particularly at commercial site (NZM site). The results of this study also suggest that the indoor RSPM concentrations are mainly composed of the finer range of particles. (c) Author(s) 2011. This work is distributed under the Creative Commons Attribution 3.0 License.
引用
收藏
页码:337 / 350
页数:14
相关论文
共 50 条
  • [1] Indoor exposure to respirable particulate matter and particulate-phase PAHs in rural homes in North India
    Ansari, Furquan Ahmad
    Khan, Altaf Husain
    Patel, Devendra Kumar
    Siddiqui, Huma
    Sharma, Shachi
    Ashquin, Mohammad
    Ahmad, Iqbal
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 170 (1-4) : 491 - 497
  • [2] Indoor exposure to respirable particulate matter and particulate-phase PAHs in rural homes in North India
    Furquan Ahmad Ansari
    Altaf Husain Khan
    Devendra Kumar Patel
    Huma Siddiqui
    Shachi Sharma
    Mohammad Ashquin
    Iqbal Ahmad
    [J]. Environmental Monitoring and Assessment, 2010, 170 : 491 - 497
  • [3] A study to characterize the suspended particulate matter in an indoor environment in Delhi, India
    Srivastava, Arun
    Jain, V. K.
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (05) : 2046 - 2052
  • [5] Characteristics of gaseous and particulate ammonia and their role in the formation of secondary inorganic particulate matter at Delhi, India
    Saraswati
    Sharma, S. K.
    Saxena, Mohit
    Mandal, T. K.
    [J]. ATMOSPHERIC RESEARCH, 2019, 218 : 34 - 49
  • [6] Indoor-outdoor relationships of respirable suspended particulate matter in two poor urban communities of Delhi
    Saksena, S
    Joshi, V
    Patil, RS
    [J]. EPIDEMIOLOGY, 2002, 13 (04) : S234 - S234
  • [7] Airborne particulate matter and gaseous air pollutants in residential structures in Lodi province, Italy
    Cattaneo, A.
    Peruzzo, C.
    Garramone, G.
    Urso, P.
    Ruggeri, R.
    Carrer, P.
    Cavallo, D. M.
    [J]. INDOOR AIR, 2011, 21 (06) : 489 - 500
  • [8] Identification of particulate matter determinants in residential homes
    Urso, Patrizia
    Cattaneo, Andrea
    Garramone, Gaetano
    Peruzzo, Carlo
    Cavallo, Domenico Maria
    Carrer, Paolo
    [J]. BUILDING AND ENVIRONMENT, 2015, 86 : 61 - 69
  • [9] A Study on Indoor/Outdoor Concentration of Particulate Matter in Rural Residential Houses in India
    Massey, David. D.
    Kulshrestha, Aditi
    Taneja, Ajay
    [J]. PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON ENVIRONMENTAL AND COMPUTER SCIENCE, 2009, : 218 - +
  • [10] Indoor and outdoor suspended particulate matter and associated carbonaceous species at residential homes in northwestern Portugal
    Custodio, Danilo
    Pinho, Isabel
    Cerqueira, Mario
    Nunes, Teresa
    Pio, Casimiro
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 473 : 72 - 76