A Memetic Algorithm for Dosimetric Optimization in CyberKnife Robotic Radiosurgical Treatment Planning

被引:0
|
作者
Clancey, Owen [1 ]
Witten, Matthew [1 ]
机构
[1] Witten Clancey Partners LLC, Great Neck, NY USA
关键词
memetic algorithm; CyberKnife; radiosurgery; treatment planning;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A memetic algorithm is proposed for optimizing beam weights for robotic radiosurgical treatments delivered via the CyberKnife (Accuray, Inc., Sunnyvale, CA) system. The fitness function includes terms representing the tumor as well as terms representing organs-at-risk, and is of a quadratic form. Optimization involves inverse treatment planning, during which a set of beam weights is sought such that the user-specified radiation dose distribution is produced by the optimized ensemble of beam weights; the dose to the tumor is maximized, while the doses to the critical structures are minimized. In the present study, four distinct CT data sets for patients with carcinoma of the prostate were used to generate eight treatment plans, so that for each data set, a hypofractionated treatment plan (5 fractions) was created, as well as a treatment plan for a standard protracted dose fractionation schedule (38 fractions). In all cases, the memetic algorithm produced a treatment plan satisfying all clinical criteria in optimization times of 22-46 minutes.
引用
收藏
页码:880 / 885
页数:6
相关论文
共 50 条
  • [1] Dosimetric planning for radiosurgical treatment of vestibular schwannomas
    Régis, J
    Levivier, M
    Wikler, D
    Porcheron, D
    [J]. NEUROCHIRURGIE, 2004, 50 (2-3) : 289 - 300
  • [2] A Mimetic Algorithm for Simultaneous Multileaf Collimator Aperture Shape and Dosimetric Optimization in CyberKnife Robotic Radiosurgery
    Witten, Matthew R.
    Clancey, Owen C.
    [J]. 2015 IEEE CONGRESS ON EVOLUTIONARY COMPUTATION (CEC), 2015, : 1589 - 1595
  • [3] Dosimetric comparison of CyberKnife with other radiosurgical modalities for an ellipsoidal target
    Yu, C
    Jozsef, G
    Apuzzo, M
    Petrovich, Z
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1342 - 1342
  • [4] Dosimetric comparison of CyberKnife with other radiosurgical modalities for an ellipsoidal target
    Yu, C
    Jozsef, G
    Apuzzo, MLJ
    Petrovich, Z
    [J]. NEUROSURGERY, 2003, 53 (05) : 1155 - 1162
  • [5] Dosimetric characterization of CyberKnife radiosurgical photon beams using polymer gels
    Pantelis, E.
    Antypas, C.
    Petrokokkinos, L.
    Karaiskos, P.
    Papagiannis, P.
    Kozicki, M.
    Georgiou, E.
    Sakelliou, L.
    Seimenis, I.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2312 - 2320
  • [6] Population-Based Metaheuristic Approximation For Dosimetric Optimization in CyberKnife Radiation Therapy Treatment Planning
    Witten, M. R.
    Clancey, O. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S851 - S851
  • [8] An analysis of the accuracy of the Cyberknife: A robotic nameless stereotactic radiosurgical system
    Chang, SD
    Main, W
    Martin, DP
    Gibbs, IC
    Heilbrun, MP
    [J]. NEUROSURGERY, 2003, 52 (01) : 140 - 146
  • [9] A reduced order memetic algorithm for constraint optimization in radiation therapy treatment planning
    Kalantzis, Georgios
    Apte, Aditya
    Radke, Richard
    Jackson, Andrew
    [J]. 2013 14TH ACIS INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING, ARTIFICIAL INTELLIGENCE, NETWORKING AND PARALLEL/DISTRIBUTED COMPUTING (SNPD 2013), 2013, : 225 - 230
  • [10] An analysis of the accuracy of the Cyberknife:: A robotic nameless stereotactic radiosurgical system -: Comments
    Kelly, PJ
    Loeffler, JS
    Bussière, MR
    Yu, C
    [J]. NEUROSURGERY, 2003, 52 (01) : 146 - 147