Untreated urban sewage contains large amounts of thermal energy; and its temperature is suitable as a heat source in heat pumps for the heating and cooling of buildings. However, it is not widely used in heat pump systems due to the problem of filth. This paper presents an untreated sewage source heat pump (USSHP) system in which auto-avoiding-clogging equipment is used to continuously capture suspended solids in the sewage. Thus, the block problems caused by filtration and fouling in the heat exchanger tubes can be efficiently resolved in this system. In an actual engineering application, the characteristic parameters of USSHP system are tested under typical operating conditions for heating status. Based on the test results, the performances of the USSHP system are examined. The results indicate that the thermal resistance of the convective heat transfer and fouling on the sewage side in the sewage exchanger is 80% of its total thermal resistance. The COP of the heat pump unit and the COP of the USSHP system are 4.3 and 3.6, respectively. (C) 2013 Published by Elsevier Ltd.
引用
收藏
页码:747 / 757
页数:11
相关论文
共 50 条
  • [1] Application of a heat pump system using untreated urban sewage as a heat source
    Liu, Zhibin
    Ma, Liangdong
    Zhang, Jili
    Applied Thermal Engineering, 2013, 61 (02) : 747 - 757
  • [2] System simulation of an untreated sewage source heat pump
    Qin N.
    Hao Z.
    International Journal of Simulation: Systems, Science and Technology, 2016, 17 (29): : 27.1 - 27.9
  • [3] Experimental study on viscosity characteristic of sewage in urban untreated sewage source heat pump system
    吴学慧
    张承虎
    赵明明
    孙德兴
    Journal of Harbin Institute of Technology(New series), 2010, (01) : 82 - 84
  • [4] Experimental study on viscosity characteristic of sewage in urban untreated sewage source heat pump system
    吴学慧
    张承虎
    赵明明
    孙德兴
    Journal of Harbin Institute of Technology, 2010, 17 (01) : 82 - 84
  • [5] SYSTEM SIMULATION FOR AN UNTREATED SEWAGE SOURCE HEAT PUMP (USSHP) IN WINTER
    Qin, Na
    Hao, Peng Z.
    SEVENTH INTERNATIONAL CONFERENCE ON ELECTRONICS AND INFORMATION ENGINEERING, 2017, 10322
  • [6] Characteristics of Fouling in Urban Sewage Source Heat Pump System
    Zhang, Chenghu
    Yang, Zhigang
    Sun, Dexing
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 1502 - 1505
  • [7] APPLICATION STUDY OF BCHP SYSTEM WITH ABSORPTION HEAT PUMP OF AN URBAN ORIGINAL SEWAGE SOURCE
    Zhao, X. L.
    Fu, L.
    Zhang, S. G.
    Zhu, J. Z.
    Huang, B. M.
    He, T.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2010, VOL 5, PTS A AND B, 2012, : 769 - 775
  • [8] Feasibility of Urban Sewage Source Heat Pump System with Freezing Latent Heat Collection
    Qian, Jianfeng
    Zhang, Jili
    Sun, Dexing
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1763 - 1768
  • [9] Application and Analysis of a Heat Pump System for Building Heating and Cooling Using Extracting Heat Energy from Untreated Sewage
    Zhuang, Zhaoyi
    Zhao, Jin
    Mi, Fengfeng
    Zhang, Teng
    Hao, Yuguo
    Li, Shangyue
    BUILDINGS, 2023, 13 (05)
  • [10] Progress of the intaking, defouling and heat transfer in sewage water side of the sewage water source heat pump system Part II: Research on urban sewage source heat pump in China
    Zhang, Jili
    Ma, Liangdong
    Liang, Ruobing
    Zhao, Tianyi
    Ma, Zhixian
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1624 - 1631