Determination of heart rate using a high-resolution temperature measurement

被引:17
|
作者
Cuadras, Angel [1 ]
Casas, Oscar [1 ]
机构
[1] Tech Univ Catalonia, Dept Elect Engn, Instrumentat Sensors & Interfaces Grp, Castelldefels Sch Technol,EPSC,UPC, Barcelona 08860, Spain
关键词
heart rate; temperature measurement; thermistor;
D O I
10.1109/JSEN.2006.874445
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A high resolution temperature measurement system able to measure temperature fluctuations down to 0.1 m C was developed. It was based on thermistors, which were fed with an ac signal to ensure a good signal-to-noise ratio (SNR). Two different configurations were tested, one unipolar and the other differential. The final system was inexpensive, easily portable and performed a noninvasive determination of temperature. It measured either volume or surface temperatures. A good SNR for both configurations using different types of thermistors was achieved. To evaluate a practical application of this system, temperature fluctuations were measured on the skin, in the proximity of different arteries, from where the heart rate was determined. The system may have many potential applications, in fields ranging from biomedicine to aerospace engineering.
引用
收藏
页码:836 / 843
页数:8
相关论文
共 50 条
  • [1] Determination of Heart Rate Variability from High-Resolution Esophageal Manometry Data
    Samoilov A.A.
    Telyshev D.V.
    [J]. Biomedical Engineering, 2018, 51 (05) : 332 - 335
  • [2] High-resolution estimation of the heart rate variability signal
    Harel, T.
    Gath, I.
    Ben-Haim, S.
    [J]. Medical and Biological Engineering and Computing, 1997, 35 (01): : 61 - 65
  • [3] High-resolution estimation of the heart rate variability signal
    T. Harel
    I. Gath
    S. Ben-Haim
    [J]. Medical and Biological Engineering and Computing, 1997, 35 : 61 - 65
  • [4] High-resolution estimation of the heart rate variability signal
    Harel, T
    Gath, I
    BenHaim, S
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) : 61 - 65
  • [5] Voltage divider resistance for high-resolution of the thermistor temperature measurement
    Kim, Jongwon
    Kim, Jong Dae
    [J]. MEASUREMENT, 2011, 44 (10) : 2054 - 2059
  • [6] High-resolution RCS measurement using MUSIC algorithm
    Yamazaki, H
    Murasaki, T
    Takahashi, R
    [J]. ELECTRONICS AND COMMUNICATIONS IN JAPAN PART I-COMMUNICATIONS, 2006, 89 (06): : 23 - 31
  • [7] Using of speckled speckles in high-resolution measurement of bioflow
    Ulyanov, SS
    [J]. FOURTH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 1999, 3904 : 510 - 518
  • [8] DEFORMATION MEASUREMENT USING HIGH-RESOLUTION MOIRE PHOTOGRAPHY
    FORNO, C
    [J]. OPTICS AND LASERS IN ENGINEERING, 1988, 8 (3-4) : 189 - 212
  • [9] High-Resolution Direct Position Determination Using MVDR
    Tzafri, Liran
    Weiss, Anthony J.
    [J]. IEEE TRANSACTIONS ON WIRELESS COMMUNICATIONS, 2016, 15 (09) : 6449 - 6461
  • [10] Measurement of respiratory rate with high-resolution accelerometer and EMFit pressure sensor
    Reinvuo, Tuomas
    Hannula, Manne
    Sorvoja, Hannu
    Alasaarela, Esko
    Myllyla, Risto
    [J]. PROCEEDINGS OF THE 2006 IEEE SENSORS APPLICATIONS SYMPOSIUM, 2006, : 192 - 195