Cycle performance evaluation of various R134a/hydrocarbon blend refrigerants applied in vapor-compression heat pumps

被引:22
|
作者
Zhang, Liu [1 ]
Zhao, Jin-xiu [1 ]
Yue, Li-fang [1 ]
Zhou, Hong-xing [1 ]
Ren, Chun-li [1 ]
机构
[1] Tangshan Univ, Dept Civil Engn, Tangshan 063000, Hebei, Peoples R China
关键词
Low global warming potential; hydrofluorocarbon; hydrocarbon; blend refrigerant; heat pump; PLUS PROPANE HC-290; LIQUID-EQUILIBRIA; BINARY-SYSTEM; MIXTURES; HFC-134A; HFC134A+HC290; ALTERNATIVES;
D O I
10.1177/1687814018819561
中图分类号
O414.1 [热力学];
学科分类号
摘要
Blend refrigerants combing hydrofluorocarbons and hydrocarbons are good substitutes to decrease the flammability of hydrocarbons while reducing the global warming potential of hydrofluorocarbons. Four hydrofluorocarbon/hydrocarbon blends (R134a/R290, R134a/R600, R134a/R600a, and R134a/R1270) with various compositions are investigated in vapor-compression heat pump cycles. The effects of hydrocarbon fraction on the blend properties, including critical temperature, critical pressure, latent heat, saturated liquid line, and azeotropic behavior, are comparatively analyzed. Thermodynamic models are established for heat pump simulation. For each R134a/hydrocarbon blend, both the cooling and heating coefficient of performances generally first decrease and then increase with the hydrocarbon mass fraction. The coefficient of performances of R134a/R600 and R134a/R600a have dramatic changes within the hydrocarbon mass fraction of 0.2-1.0, while those of R134a/R290 and R134a/R1270 have dramatic changes within the fraction of 0.0-0.4. Lower condensing or higher evaporating temperatures lead to higher coefficient of performances. In addition, the volumetric capacities first increase and then decrease with the increase of hydrocarbon fraction. R134a/R290 and R134a/R1270 show much higher volumetric capacities as compared to R134a/R600 and R134a/R600a under higher hydrocarbon fractions, which can greatly reduce the required compressor size of pure R134a. The discharge temperatures are kept in the range of 43.0 degrees C-72.3 degrees C for all the blends. To obtain low global warming potential R134a/hydrocarbon blends, the hydrocarbon fraction need to be greater than 0.9, at which R134a/R 1270 performs the best, with cooling/heating coefficient of performances of 5.25/4.70 and cooling/heating volumetric capacities of 4.78/3.53 MJ/m(3). Generally, R134a/R290 and R134a/R1270 perform much better than R134a/R600 and R134a/R600a at the low global warming potential composition. This study can contribute to the determination of hydrofluorocarbon/hydrocarbon compositions based on comprehensive considerations of cycle efficiency, volumetric capacity, and low global warming potential target.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Performance analysis of refrigerants R134a two stage compression cycle with an expander
    Xue, Guijun
    Liang, Dawei
    Liu, Guangda
    Li, Shuiqing
    Zhou, Zhenjiang
    [J]. MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 2786 - 2789
  • [2] EXPERIMENTAL INVESTIGATION ON R134A AIRBORNE VAPOR-COMPRESSION REFRIGERATION SYSTEM
    李运祥
    潘泉
    刘娟
    [J]. Transactions of Nanjing University of Aeronautics and Astronautics, 2013, (01) : 46 - 52
  • [3] COMPARISON OF R-134A AND R-12 REFRIGERANTS IN A VAPOR-COMPRESSION SYSTEM
    RIFFAT, SB
    SHANKLAND, NJ
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1993, 17 (05) : 439 - 442
  • [4] R134a and various mixtures of R22/R134a as an alternative to R22 in vapour compression heat pumps
    Karagoz, S
    Yilmaz, M
    Comakli, O
    Ozyurt, O
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (02) : 181 - 196
  • [5] EXPERIMENTAL INVESTIGATION ON R134A AIRBORNE VAPOR-COMPRESSION REFRIGERATION SYSTEM
    李运祥
    潘泉
    刘娟
    [J]. Transactions of Nanjing University of Aeronautics & Astronautics, 2013, 30 (01) : 46 - 52
  • [6] PERFORMANCE COEFFICIENT OF VAPOR-COMPRESSION HEAT-PUMPS
    PROTSENKO, VP
    RADCHENKO, VA
    [J]. THERMAL ENGINEERING, 1988, 35 (08) : 458 - 461
  • [7] Controversial Analyzing of a Vapor-Compression Cycle in Various Climatic Conditions Using Various Refrigerants
    Zand, Mazyar
    Vaghefi, Seyed Ali Sadr
    Mousavi, Seyed Zaeim
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2022, 144 (10):
  • [8] Performance analysis of refrigerants R134a two stage compression cycle with two gas cooler
    Xue, Guijun
    Liang, Dawei
    Liu, Guangda
    Li, Shuiqing
    Zhou, Zhenjiang
    [J]. MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 2782 - 2785
  • [9] Comparative Performance of Low-GWP Refrigerants as Substitutes for R134a in a Vapor Compression Refrigeration System
    Hamza, Ameer
    Khan, Tauseef Aized
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (07) : 5697 - 5712
  • [10] Comparative Performance of Low-GWP Refrigerants as Substitutes for R134a in a Vapor Compression Refrigeration System
    Ameer Hamza
    Tauseef Aized Khan
    [J]. Arabian Journal for Science and Engineering, 2020, 45 : 5697 - 5712