Influence of Bladder Volume on the Dose to the Target and Organs at Risk in High Dose Rate Intracavitary Brachytherapy of Cervix

被引:0
|
作者
Rangarajan, Ramya [1 ]
Saravanan, S. [1 ]
Kumari, K. [1 ]
机构
[1] Govt Royapettah Hosp, Dept Radiat Oncol, Chennai, Tamil Nadu, India
关键词
Bladder volume; Intracavitary brachytherapy; Cervical cancer; DISTENSION; CANCER; DOSIMETRY;
D O I
10.1007/s40944-022-00645-w
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim The aim of this study is to report the influence of bladder volume on the dose to the target and OAR in CT-based high dose rate intracavitary brachytherapy of cervix and to determine the optimal bladder volume required during intracavitary brachytherapy. Materials and Methods A total of 100 CT datasets of cervical cancer patients were taken up for analysis. The volumes of the target and the organs at risk were contoured. Dose volume histograms were generated and the dose to 0.1 cc, 1 cc and 2 cc of bladder, rectum and sigmoid and dose received by 90% of the clinical target volume were recorded. CT datasets were divided into two cohorts-bladder volume less than 70 ml and bladder volume more than 70 ml and the differences in dosimetry were computed. Results Fifty-three applications with bladder volume less than 70 ml and 51 applications with bladder volume more than 70 ml were analyzed. Volume of bladder filling did not have a significant impact on the dose delivered to 0.1 cc, 1 cc and 2 cc of bladder (p value= 0.87, 0.45, 0.19, respectively). The dose to the rectum was significantly lower when the bladder volume was less than 70 ml. (p value = 0.016, 0.008 and 0.003, respectively). Bladder distension did not significantly affect the dose delivered to the sigmoid or D90CTV. Conclusions Bladder volume more than 70 ml had a significant impact on the rectal dosimetry in our study. Bladder volume did not affect the dose to the other organs at risk and the target. Based on our study results, we conclude that the bladder volume should be less than 70 ml in order to avoid more doses to the rectum.However, we need to analyze a larger cohort of patients to derive any finite conclusions.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Influence of Bladder Volume on the Dose to the Target and Organs at Risk in High Dose Rate Intracavitary Brachytherapy of Cervix
    Ramya Rangarajan
    S. Saravanan
    K. Kumari
    Indian Journal of Gynecologic Oncology, 2022, 20
  • [2] Dosimetric analysis of the effects of the bladder volume on organs at risk (OAR) in high-dose-rate intracavitary brachytherapy in carcinoma cervix an institutional study
    Das Sharma, Ashutosh
    Poddar, Jyoti
    Suryanarayan K, U.
    Shah, Sonal Patel
    Parikh, Ankita
    Mehta, Vimesh
    Kumar, Tarun
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2018, 10 (01) : 26 - 31
  • [3] Dose-volume histogram analysis of high dose rate intracavitary brachytherapy for uterine cervix cancer
    Terahara, A
    Nakano, T
    Ishikawa, A
    Morita, S
    Tsujii, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (03): : 549 - 554
  • [5] Low dose rate and high dose rate intracavitary brachytherapy in a patient with carcinoma of the cervix
    Tan, LT
    Jones, B
    Freestone, G
    Dale, RG
    BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (817): : 84 - 86
  • [6] Dosimetric analysis of the effect of bladder volume on brachytherapy dose to organs at risk (OARs) in volume based intracavitary brachytherapy of carcinoma cervix: An institutional study.
    Poddar, Jyoti
    Das Sharma, Ashutosh
    Suryanarayan, U. K.
    Shah, Sonal Patel
    Parikh, Ankita
    JOURNAL OF CLINICAL ONCOLOGY, 2017, 35
  • [7] Bladder distension improves the dosimetry of organs at risk during intracavitary cervical high-dose-rate brachytherapy
    Harmon, Grant
    Chinsky, Bonnie
    Surucu, Murat
    Harkenrider, Matthew
    Small, William, Jr.
    BRACHYTHERAPY, 2016, 15 (01) : 30 - 34
  • [8] Reporting of inter fraction dose variations of organs at risk in computed tomography-guided high dose rate intracavitary brachytherapy in carcinoma cervix
    Nandi, Moujhuri
    Pokala, Neelima
    Perumareddy, Vaishnavi
    Sarkar, Sujata
    Chanda, Sudeep
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (04) : 394 - 397
  • [9] Effect of bladder distention on bladder base dose in gynaecological intracavitary high dose rate brachytherapy
    Adli, M.
    Garipagaoglu, M.
    Kocak, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (975): : 243 - 248
  • [10] HIGH-DOSE-RATE VERSUS LOW-DOSE-RATE INTRACAVITARY BRACHYTHERAPY FOR CARCINOMA OF THE CERVIX
    FU, KK
    PHILLIPS, TL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (03): : 791 - 796