Psychometrics of the Patient-Reported Outcomes Measurement Information System Physical Function instrument administered by computerized adaptive testing and the Disabilities of Arm, Shoulder and Hand in the orthopedic elbow patient population

被引:28
|
作者
Hung, Man [1 ]
Voss, Maren W. [1 ]
Bounsanga, Jerry [1 ]
Gu, Yushan [1 ]
Granger, Erin K. [1 ]
Tashjian, Robert Z. [1 ]
机构
[1] Univ Utah, Dept Orthopaed Surg Operat, Salt Lake City, UT 84108 USA
基金
美国国家卫生研究院;
关键词
PROMIS; DASH; physical function; psychometric; orthopedics; elbow; FUNCTION ITEM BANK; UPPER EXTREMITY; RESPONSE THEORY; PROMIS; QUESTIONNAIRE; RESPONSIVENESS; DASH; CARE;
D O I
10.1016/j.jse.2017.10.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study evaluated the psychometric properties of the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF) instrument administered through computerized adaptive testing (CAT) compared with the traditional full-length Disabilities of the Arm, Shoulder and Hand (DASH). Methods: The PROMIS PF CAT and the DASH were administered to 1759 patients seeking care for elbow conditions. This study used Rasch partial credit modeling to analyze the instruments with item fit, internal reliability, response category thresholds, dimensionality, local independence, gender differential item functioning, and floor and ceiling effects. Results: The PROMIS PF CAT and DASH had satisfactory item fit for all but 1 item on both measures. Internal reliabilities were high for both measures. Two items on the DASH and 4 items on the PF CAT showed nonordered category thresholds. Unidimensionality was adequate, and local independence was supported for both instruments. Gender bias was found for 4 items on the PF CAT and 12 items on the DASH. Both measures had adequate instrument targeting and satisfactory floor and ceiling effects. Conclusion: The PROMIS PF CAT and the DASH both showed sufficient unidimensionality, good item fit, and good local independence with the exception of high levels of gender item bias, particularly for the DASH. Further scale evaluation should address item bias and item response categories for these instruments. Overall, the PROMIS PF CAT is an effective outcome instrument to measure function in patients with elbow disorders that requires significantly fewer questions than the DASH. (C) 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:515 / 522
页数:8
相关论文
共 50 条
  • [1] Convergent Validity of the Patient-Reported Outcomes Measurement Information System's Physical Function Computerized Adaptive Test for the Knee and Shoulder Injury Sports Medicine Patient Population
    Robins, Richard Judd
    Anderson, Mike B.
    Zhang, Yingying
    Presson, Angela P.
    Burks, Robert T.
    Greis, Patrick E.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (03): : 608 - 616
  • [2] Mapping physical functions of the shoulder to American Shoulder and Elbow Surgeons and Patient-Reported Outcomes Measurement Information System scores
    Roberts, Aaron M.
    Voloshin, Ilya
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (04) : 707 - 718
  • [3] The Recovery Curve for the Patient-Reported Outcomes Measurement Information System Patient-Reported Physical Function and Pain Interference Computerized Adaptive Tests After Primary Total Knee Arthroplasty
    Kagan, Ryland
    Anderson, Mike B.
    Christensen, Jesse C.
    Peters, Christopher L.
    Gililland, Jeremy M.
    Pelt, Christopher E.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08): : 2471 - 2474
  • [4] Impact of Patient Demographic Factors on Preoperative Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function, Pain Interference, and Depression Computer Adaptive Testing Scores in Patients Undergoing Shoulder and Elbow Surgery
    Meldau, Jason E.
    Borowsky, Peter
    Blanchett, Jacob
    Stephens, Jeffrey
    Muh, Stephanie
    Moutzouros, Vasilios
    Makhni, Eric C.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (11)
  • [5] Relative Performance of Commonly Used Physical Function Questionnaires in Rheumatoid Arthritis and a Patient-Reported Outcomes Measurement Information System Computerized Adaptive Test
    Voshaar, Martijn A. H. Oude
    ten Klooster, Peter M.
    Glas, Cees A. W.
    Vonkeman, Harald E.
    Krishnan, Eswar
    van de Laar, Mart A. F. J.
    ARTHRITIS & RHEUMATOLOGY, 2014, 66 (10) : 2900 - 2908
  • [6] Correlation of Patient-Reported Outcome Measurement Information System Physical Function Upper Extremity Computer Adaptive Testing, With the American Shoulder and Elbow Surgeons Shoulder Assessment Form and Simple Shoulder Test in Patients With Shoulder Pain
    Minoughan, Chelsea E.
    Schumaier, Adam P.
    Fritch, John L.
    Grawe, Brian M.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (05): : 1430 - 1436
  • [7] Use of the Patient-Reported Outcomes Measurement Information System (PROMIS) for Operative Shoulder Outcomes
    Schwarz, Ilona
    Smith, John-Rudolph H.
    Houck, Darby A.
    Frank, Rachel M.
    Bravman, Jonathan T.
    McCarty, Eric C.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (06)
  • [8] Comparison of Patient-Reported Outcomes Measurement Information System Computerized Adaptive Testing Versus Fixed Short Forms in Juvenile Myositis
    Patel, Ruchi N.
    Esparza, Valeria G.
    Lai, Jin-Shei
    Gray, Elizabeth L.
    Reeve, Bryce B.
    Chang, Rowland W.
    Cella, David
    Ardalan, Kaveh
    ARTHRITIS CARE & RESEARCH, 2023, 75 (02) : 381 - 390
  • [9] The Current Utilization of Patient-reported Outcome Measurement Information System in Shoulder, Elbow, and Sports Medicine
    Trofa, David P.
    Desai, Sohil S.
    Li, Xinning
    Makhni, Eric C.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (12) : 554 - 562
  • [10] Patient-Reported Outcomes Measurement Information System physical function and pain interference in spine surgery
    Khalifeh, Jawad M.
    Dibble, Christopher F.
    Hawesli, Ammar H.
    Ray, Wilson Z.
    JOURNAL OF NEUROSURGERY-SPINE, 2019, 31 (02) : 165 - 174