Postoperative blood salvage and reinfusion after total joint arthroplasty

被引:56
|
作者
Han, CD
Shin, DE
机构
[1] Department of Orthopaedic Surgery, Yonsei University, College of Medicine, Seoul
[2] Department of Orthopaedic Surgery, Yonsei University, College of Medicine, Seoul 120-752
来源
JOURNAL OF ARTHROPLASTY | 1997年 / 12卷 / 05期
关键词
postoperative autotransfusion; total hip arthroplasty; total knee arthroplasty;
D O I
10.1016/S0883-5403(97)90173-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this prospective study was to evaluate the safety of salvage and reinfusion of postoperative sanguineous wound drainage using the ConstaVac Blood Conservation System (Stryker, Kalamazoo, MI). A prospective analysis of 135 primary total hip and total knee arthroplasties was carried out. The collection time for reinfusion was limited to 6 hours, and suction pressure was kept to a minimum by using the lowest setting on the device. For all patients, no citrate-phosphate-dextrose anticoagulant was added to the reservoir. To evaluate the effect of reinfusion on hemostasis and the blood coagulation system, antithrombin III, fibrinogen, and D-dimer levels of 40 of 135 patients were measured before surgery and on the first and seventh days after the operation. The mean volume of reinfusion of postoperative drainage was 437 mL for the patients with total hip arthroplasties, 883 mt for those with total knee arthroplasties, and 1,713 mt for those with bilateral total knee arthroplasties. Ninety-nine of 135 patients underwent operations without homologous blood replacement. Transient chills with mild fever were seen in 2 patients during reinfusion. No complications related to air embolism, coagulopathy, renal failure, or sepsis were recognized in any of the patients. This study suggests that postoperative blood salvage and reinfusion appear to be safe and effective in patients undergoing primary total hip and knee arthroplasties.
引用
收藏
页码:511 / 516
页数:6
相关论文
共 50 条
  • [1] Postoperative blood salvage and reinfusion after total hip joint arthroplasty -: Does it make sense?
    Reize, P.
    Endele, D.
    Rudert, M.
    Wuelker, N.
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2006, 144 (04): : 400 - 404
  • [2] POSTOPERATIVE BLOOD SALVAGE USING THE CELL SAVER AFTER TOTAL JOINT ARTHROPLASTY
    SEMKIW, LB
    SCHURMAN, DJ
    GOODMAN, SB
    WOOLSON, ST
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (06): : 823 - 827
  • [3] Effectiveness of the postoperative blood salvage after total knee arthroplasty
    Ferrandis, R.
    Chisvert, J. V.
    Llau, J. V.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 86 - 87
  • [4] POSTOPERATIVE COLLECTION AND REINFUSION OF AUTOLOGOUS BLOOD IN TOTAL KNEE ARTHROPLASTY
    MAJKOWSKI, RS
    NEWMAN, JH
    CURRIE, IC
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1991, 73 (06) : 381 - 384
  • [5] POSTOPERATIVE BLOOD SALVAGE AFTER PRIMARY TOTAL HIP-ARTHROPLASTY
    KICK, O
    BODERE, R
    BERNARD, JM
    BOURRELI, B
    SOURON, R
    [J]. ANESTHESIOLOGY, 1995, 83 (3A) : A1001 - A1001
  • [7] Postoperative ileus after total joint arthroplasty
    Parvizi, Javad
    Han, Seung-Beom
    Tarity, T. David
    Pulido, Luis
    Weinstein, Michael
    Rothman, Richard H.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 360 - 365
  • [8] Postoperative Blood Glucose Levels Predict Infection After Total Joint Arthroplasty
    Kheir, Michael M.
    Tan, Timothy L.
    Kheir, Matthew
    Maltenfort, Mitchell G.
    Chen, Antonia F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (16): : 1423 - 1431
  • [9] Blood salvage after total hip and total knee arthroplasty
    Xenakis, TA
    Malizos, KN
    Dailiana, Z
    Koukoubis, T
    Zervou, E
    Golegou, C
    Soucacos, PN
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1997, 68 : 135 - 138
  • [10] Reinfusion of shed blood in total knee arthroplasty
    Pitsaer, E
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2002, 88 (08): : 777 - 789