High Loaded Bioflocculation Membrane Reactor of Novel Structure for Organic Matter Recovery from Sewage: Effect of Temperature on Bioflocculation and Membrane Fouling

被引:3
|
作者
Wan, Liguo [1 ,2 ,3 ]
Xiong, Ling [2 ]
Zhang, Lijun [2 ]
Lu, Wenxi [1 ]
机构
[1] Jilin Univ, Coll New Energy & Environm, Changchun 130021, Peoples R China
[2] Changchun Inst Technol, Sch Water Conservancy & Environm Engn, Changchun 130012, Peoples R China
[3] Changchun Inst Technol, Jilin Prov Key Lab Municipal Wastewater Treatment, Changchun 130012, Peoples R China
关键词
membrane reactor; bioflocculation; temperature; organic matter; municipal wastewater; EXTRACELLULAR POLYMERIC SUBSTANCES; ACTIVATED-SLUDGE; WATER-TREATMENT; LOW-PRESSURE; COAGULATION; PERFORMANCE; MICROFILTRATION; FLOCCULATION; PRETREATMENT; SURFACE;
D O I
10.3390/w12092497
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The effect of temperature on the efficiency of high loaded bioflocculation membrane reactor (HLB-MR) flocculation and concentration of organic matter in municipal wastewater was analyzed using parallel comparative experiments. The study investigated organic matter recovery efficiency, bioflocculation effect, and membrane fouling status of the reactor at 8 degrees C and 15 degrees C. It was observed that at a low temperature of 8 degrees C, the organic matter recovery efficiency of HLB-MR was 80%, which was equivalent to that at 15 degrees C. However, the bioflocculation efficiency at 8 degrees C was only 65%, which was significantly lower than that of 85% achieved at 15 degrees C. The poor flocculation effect was related to the low yield of the extracellular polymer under low-temperature conditions and the low content of cations (sodium, calcium, and aluminum) in the sludge matrix. At the low temperature of 8 degrees C, the membrane fouling of the HLB-MR was more serious than that at 15 degrees C. Poor bioflocculation effect led to an increase in the number of fine particles (<= 1 mu m) in the reactor, which might be the main reason for the aggravation of membrane fouling. To overcome the adverse effects of low temperature on membrane fouling, it is recommended to adopt engineering measures, such as an appropriate increase in the solid retention time, increase in the aeration intensity, using powdered activated carbon, or enhancing the intensity of backwashing.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] High-Loaded Bioflocculation Membrane Reactor of Novel Structure for Organic Matter Recovery from Sewage: Effect of Dissolved Oxygen on Bioflocculation and Membrane Fouling
    Wan, Liguo
    Xiong, Ling
    Zhang, Lijun
    Lu, Wenxi
    [J]. SUSTAINABILITY, 2020, 12 (18)
  • [2] Effect of dissolved oxygen on bioflocculation of organic matter in high loaded bioflocculation membrane reactor
    Wan, Li-Guo
    Lin, Qiao
    Zhang, Li-Jun
    Zhang, Wen-Hua
    Liu, Hong-Bo
    Long, Bei-Sheng
    Xiong, Ling
    [J]. Zhongguo Huanjing Kexue/China Environmental Science, 2019, 39 (08): : 3340 - 3346
  • [3] Feasibility of bioflocculation in a high-loaded membrane bioreactor for improved energy recovery from sewage
    Akanyeti, Ime
    Temmink, Hardy
    Remy, Maxime
    Zwijnenburg, Arie
    [J]. WATER SCIENCE AND TECHNOLOGY, 2010, 61 (06) : 1433 - 1439
  • [4] Direct treatment and organics recovery of municipal wastewater via high loaded bioflocculation membrane reactor
    Wan, Li-Guo
    Lin, Qiao
    Zhang, Wen-Hua
    Ren, Zhi-Min
    Long, Bei-Sheng
    Xiong, Ling
    [J]. Zhongguo Huanjing Kexue/China Environmental Science, 2019, 39 (04): : 1596 - 1601
  • [5] High loaded MBRs for organic matter recovery from sewage: Effect of solids retention time on bioflocculation and on the role of extracellular polymers
    Faust, L.
    Temmink, H.
    Zwijnenburg, A.
    Kemperman, A. J. B.
    Rijnaarts, H. H. M.
    [J]. WATER RESEARCH, 2014, 56 : 258 - 266
  • [6] Calcium ion on membrane fouling reduction and bioflocculation promotion in membrane bioreactor at high salt shock
    Zhang, Haifeng
    Fan, Xue
    Wang, Bin
    Song, Lianfa
    [J]. BIORESOURCE TECHNOLOGY, 2016, 200 : 535 - 540
  • [7] The application of membrane sequencing batch reactors in high rate activated sludge processes: the effect of the organic loading rate on the bioflocculation and fouling phenomenon
    Shafaei, Nader
    Bonakdarpour, Babak
    Faridizad, Ghazale
    [J]. ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2022, 8 (07) : 1561 - 1578
  • [8] Effect of bioflocculation on fouling-related biofoulants in a membrane bioreactor during saline wastewater treatments
    Tan, Songwen
    Cui, Chunzhi
    Chen, Xuncai
    Li, Weiguo
    [J]. BIORESOURCE TECHNOLOGY, 2017, 224 : 285 - 291
  • [9] Volatile fatty acids production from sewage organic matter by combined bioflocculation and anaerobic fermentation
    Khiewwijit, Rungnapha
    Keesman, Karel J.
    Rijnaarts, Huub
    Temmink, Hardy
    [J]. BIORESOURCE TECHNOLOGY, 2015, 193 : 150 - 155
  • [10] Production of volatile fatty acids from sewage organic matter by combined bioflocculation and alkaline fermentation
    Khiewwijit, Rungnapha
    Temmink, Hardy
    Labanda, Alvaro
    Rijnaarts, Huub
    Keesman, Karel J.
    [J]. BIORESOURCE TECHNOLOGY, 2015, 197 : 295 - 301