Comparison between HPGe and CdZnTe detector for the correlation between calculated radioactivity and measured dose using an activated concrete sample

被引:1
|
作者
Chaudhury, Sanhita [1 ]
Agarwal, Chhavi [1 ]
Goswami, A. [1 ]
Gathibandhe, Manohar [2 ]
机构
[1] Bhabha Atom Res Ctr, Div Radiochem, Bombay 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Reactor Projects Div, Bombay 400085, Maharashtra, India
关键词
PHT pipeline; MCNP code; Efficiency; CdZnTe detector; Gamma ray; NUCLEAR; SAFEGUARDS; COOLANT;
D O I
10.1007/s10967-011-1475-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An activated concrete sample was counted at different source to detector distances with CdZnTe and HPGe detectors. The experimental count rates for different radionuclides were converted to dose rate using Monte Carlo code and compared with the Measured dose rates obtained using digital survey meter. The results agreed well for both the detectors. This indicates that CdZnTe detector having a better portability but poorer resolution than HPGe detector can be effectively used for online monitoring of radioactivity as well as dose rate calculations.
引用
收藏
页码:461 / 464
页数:4
相关论文
共 19 条
  • [1] Comparison between HPGe and CdZnTe detector for the correlation between calculated radioactivity and measured dose using an activated concrete sample
    Sanhita Chaudhury
    Chhavi Agarwal
    A. Goswami
    Manohar Gathibandhe
    Journal of Radioanalytical and Nuclear Chemistry, 2012, 294 : 461 - 464
  • [2] COMPARISON BETWEEN CALCULATED AND MEASURED DOSE DISTRIBUTIONS IN TANGENTIAL PENDULUM IRRADIATION OF MAMMA
    RICHTER, J
    WILL, W
    STRAHLENTHERAPIE, 1973, 145 (05) : 561 - 564
  • [4] Analysis of Correlation between Dwell Time Measured using Bluetooth Detector and Occupancy
    Cvetek, Dominik
    Horenec, Isabela
    Mustra, Mario
    Jelusic, Niko
    2019 61ST INTERNATIONAL SYMPOSIUM ELMAR, 2019, : 31 - 34
  • [5] COMPARISON BETWEEN MEASURED AND CALCULATED EQUIVALENT DOSES IN CT USING ANTHROPOMORPHIC PEDIATRIC PHANTOMS
    Chipiga, Larisa
    Shleenkova, Ekaterina
    Bernhardsson, Christian
    MEDICAL PHYSICS IN THE BALTIC STATES, 2015, : 96 - 99
  • [6] Comparison between measured and calculated dynamic wedge dose distributions using the anisotropic analytic algorithm and pencil-beam convolution
    Caprile, Paola
    Venencia, Carlos Daniel
    Besa, Pelayo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (01): : 47 - 54
  • [7] COMPARISON BETWEEN OXYGEN-CONSUMPTION CALCULATED BY FICKS PRINCIPLE USING A CONTINUOUS THERMODILUTION TECHNIQUE AND MEASURED BY INDIRECT CALORIMETRY
    BIZOUARN, P
    BLANLOEIL, Y
    PINAUD, M
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 75 (06) : 719 - 723
  • [8] SIGNIFICANT CORRELATION BETWEEN SALIVARY FLOW CALCULATED USING PRE-TREATMENT SCINTIGRAPHY AND MEASURED SALIVARY FLOW AFTER RADIOTHERAPY
    Tuomikoski, L.
    Collan, J.
    Kapanen, M.
    Nyman, H.
    Jani, K.
    Kajanti, M.
    Saarilahti, K.
    Tenhunen, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 : S33 - S34
  • [9] CORRELATION BETWEEN THE TUMOR SIZE MEASURED BY USING CHEST RADIOGRAPH AND CT CHEST COMPARISON TO THE PATHOLOGIC SIZE
    Hantrakul, Thatchai
    Euathrongchit, Juntima
    Wannasopha, Yutthaphan
    Lertprasertsuke, Nirush
    Saeteng, Somcharoen
    Tantraworasin, Apichat
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S681 - S681
  • [10] The Dosimetric Comparison between Measured Tissue Maximum Ratio Directly by Water Phantom and That Calculated from Percentage Depth Dose Measurments in Small Field and Determind the Differnces between Two Methods
    Attalla, Ehab Marouf
    Shoer, Shaimaa
    Elawady, Rasha A.
    Iranian Journal of Medical Physics, 2021, 18 (06) : 384 - 388