Analysis of Intraocular lens power calculation for eyes with previous myopic LASIK

被引:0
|
作者
Jin, GJC
Crandall, AS
Jin, Y
机构
[1] Eye Inst Utah, Salt Lake City, UT 84107 USA
[2] Univ Utah, Moran Eye Ctr, Salt Lake City, UT USA
[3] Univ Iowa, Dept Ophthalmol, Iowa City, IA 52242 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the effectiveness of a manual keratometry (K) adjusted value for intraocular lens (IOL) power calculation in patients who underwent cataract surgery following previous myopic LASIK. METHODS: Sixteen eyes of 14 consecutive patients who underwent cataract surgery after previous LASIK were evaluated retrospectively. All IOL powers were calculated using an adjusted K value (K minus 1.0 diopter [D]) with the Binkhorst 11 formula aiming for -0.75 to -1.00 D final refraction. Additionally, the IOL power for each eye was retrospectively calculated using K, refractive-derived K, and adjusted K with the Binkhorst 11, Holladay 1, and SRK/T formulas. The final refraction was used as a criterion of accuracy of each approach. RESULTS: Uncorrected visual acuity >= 20/40 was achieved in 14 (87.5%) of 16 eyes. The mean postoperative spherical equivalent refraction was -0.41 +/- 0.57 D (range: +0.50 to -2.00 D). Twelve (75%) of 16 eyes were within +/- 0.50 D of emmetropia and 15 (94%) of 16 eyes were within +/- 1.00 D. No eye was > + 1.00 D. CONCLUSIONS: Using an adjusted K with the Binkhorst 11 formula, aiming for -0.75 to -1.00 D, and with the Holladay I formula, aiming for -0.50 to - 1.00 D, measuring K with a regular manual keratometer permits determination of an IOL power after myopic LASIK without the need of preoperative LASIK refractive data.
引用
收藏
页码:387 / 395
页数:9
相关论文
共 50 条
  • [1] Intraocular lens power calculation for eyes with previous myopic LASIK - Reply
    Lin, George I. C.
    Crandall, Alan S.
    Jin, Yian
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) : 847 - 848
  • [2] Intraocular lens power calculation in high myopic eyes with previous radial keratotomy
    Han, Eui Seok
    Lee, Jin Hak
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 713 - 716
  • [3] Intraocular lens power in myopic eyes
    Savini, Giacomo
    Ducoli, Pietro
    Hoffer, Kenneth J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1340 - 1341
  • [4] Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [5] Intraocular lens power calculation and optimized constants for highly myopic eyes
    Petermeier, Katrin
    Gekeler, Florian
    Messias, Andre
    Spitzer, Martin S.
    Haigis, Wolfgang
    Szurman, Peter
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09): : 1575 - 1581
  • [6] Accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [7] Error analysis of intraocular lens power in eyes after LASIK
    Lin, JT
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (02) : 127 - 128
  • [8] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    [J]. EYE AND VISION, 2018, 5
  • [9] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Anders, Philipp
    Anders, Lisa-Marie
    Barbara, Adel
    Szentmary, Nora
    Langenbucher, Achim
    Gatzioufas, Zisis
    [J]. THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2022, 14
  • [10] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Giacomo Savini
    Kenneth J. Hoffer
    [J]. Eye and Vision, 5