Direct analysis of liquid drugs by inductively coupled plasma mass spectrometry using aerosol dilution

被引:7
|
作者
Lorencatto, Rodolfo [1 ,2 ]
Arantes de Carvalho, Gabriel Gustinelli [1 ]
Oliveira, Pedro Vitoriano [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, Av Prof Lineu Prestes 748, BR-05513970 Sao Paulo, SP, Brazil
[2] Agilent Technol Brazil, Alameda Araguaia 1142, BR-06455000 Barueri, Brazil
基金
巴西圣保罗研究基金会;
关键词
ACTIVE PHARMACEUTICAL INGREDIENTS; RARE-EARTH-ELEMENTS; DOUBLY-CHARGED IONS; ICP-MS; IMPURITIES; SAMPLES; INTERFERENCES; CR;
D O I
10.1039/d0ja00083c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work a method for the direct analysis of liquid drug samples by inductively coupled plasma mass spectrometry (ICP-MS) with aerosol dilution was proposed. Multivariate studies were executed for optimization of ICP-MS parameters (sample depth, aerosol dilution gas flow rate and He gas flow rate) using a representative diluted drug sample aiming at appropriate plasma robustness parameters (Ce-140(2+)/Ce-140(+) and (CeO+)-Ce-140-O-16/Ce-140(+) ratios), as well as sensitivity for Ag, As, Au, Ba, Cd, Co, Cr, Cu, Hg, Ir, Li, Mo, Ni, Os, Pb, Pd, Pt, Rh, Ru, Sb, Se, Sn, Tl and V, the elemental impurities in USP Chapter 232. The results showed that the dilution gas had a major role in formation of doubly charged and oxide ions. A robust plasma condition was achieved (i.e., Ce-140(2+)/Ce-140(+) < 0.9% and (CeO+)-Ce-140-O-16/Ce-140(+) < 0.3%) when 0.40 L min(-1) dilution gas flow rate was used. The combination of collision (He) gas and dilution gas flow rates was the key feature for minimizing (or even removing) polyatomic interferences. It was verified that collision cell processes benefit from less sample matrix introduction provided by aerosol dilution. Method validation has been accomplished and reported for a liquid drug for hepatic disorders. The results successfully met the requirements of the USP Chapter 233 procedure, wherein appropriate figures of merit were obtained (R > 0.995 and RSD < 6.2% for precision tests, RSD < 14% for intermediate precision tests, and 88-125% recoveries for a 50-fold diluted spiked sample with different J concentrations). This study provided useful information about the benefits of aerosol dilution and demonstrates that ICP-MS with aerosol dilution is a reliable method for the direct analysis of liquid drug samples in order to meet the requirements of USP Chapters 232 and 233.
引用
收藏
页码:2179 / 2190
页数:12
相关论文
共 50 条
  • [1] Direct analysis of biodiesel microemulsions using an inductively coupled plasma mass spectrometry
    Amais, Renata S.
    Garcia, Edivaldo E.
    Monteiro, Marcos R.
    Nogueira, Ana Rita A.
    Nobrega, Joaquim A.
    MICROCHEMICAL JOURNAL, 2010, 96 (01) : 146 - 150
  • [2] Nutritional supplement contamination analysis by traditional and speciated isotope dilution mass spectrometry using liquid chromatography inductively coupled plasma-mass spectrometry
    Frantz, Curtis
    Kingston, Skip
    Rahman, Mizan
    Zinn, Greg
    Roeske, Liz
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [3] Direct elemental analysis of biodiesel by inductively coupled plasma–mass spectrometry
    G. D. Woods
    F. I. Fryer
    Analytical and Bioanalytical Chemistry, 2007, 389 : 753 - 761
  • [4] Aerosol detection efficiency in inductively coupled plasma mass spectrometry
    Hubbard, Joshua A.
    Zigmond, Joseph A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 119 : 50 - 64
  • [5] Determination of dibutyltin in Sediments using isotope dilution liquid chromatography-inductively coupled plasma mass spectrometry
    Yim, YH
    Park, JY
    Han, XS
    Park, MK
    Kim, BJ
    Lim, YG
    Hwang, EJ
    So, HY
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2005, 26 (03) : 440 - 446
  • [7] Inductively coupled plasma mass spectrometry and standard dilution analysis applied to concentrated acids
    Virgilio, Alex
    Schiavo, Daniela
    Costa, Leticia M.
    Nobrega, Joaquim A.
    Jones, Bradley T.
    Donati, George L.
    TALANTA, 2016, 161 : 826 - 829
  • [8] The determination of chlorine in plastic using isotope dilution inductively coupled plasma mass spectrometry
    Ohata, Masaki
    Wada, Ayaka
    ANALYTICAL METHODS, 2017, 9 (26) : 4004 - 4010
  • [9] Inductively coupled plasma mass spectrometry in the analysis of biological samples and pharmaceutical drugs
    Ossipov, Konstantin
    Seregina, Irina F.
    Bolshov, Mikhail A.
    RUSSIAN CHEMICAL REVIEWS, 2016, 85 (04) : 335 - 355
  • [10] Direct determination of urinary iodine by inductively coupled plasma mass spectrometry using isotope dilution with iodine-129
    Haldimann, M
    Zimmerli, B
    Als, C
    Gerber, H
    CLINICAL CHEMISTRY, 1998, 44 (04) : 817 - 824