Regadenoson: Review of Its Established Role in Myocardial Perfusion Imaging and Emerging Applications

被引:11
|
作者
Palani, Gurunanthan [2 ]
Ananthasubramaniam, Karthikeyan [1 ]
机构
[1] Henry Ford Hosp, Inst Heart & Vasc, Detroit, MI 48202 USA
[2] McLaren Michigan State Univ, Dept Internal Med, Flint, MI USA
关键词
pharmacologic stress myocardial perfusion imaging; regadenoson; adenosine; coronary artery disease; chronic kidney disease; chronic obstructive pulmonary disease; coronary flow reserve; stress echocardiography; dipyridamole; OBSTRUCTIVE PULMONARY-DISEASE; PHARMACOLOGICAL STRESS AGENT; ADENOSINE RECEPTOR AGONISTS; INITIAL CLINICAL-EXPERIENCE; SELECTIVE A(2A) AGONIST; DOUBLE-BLIND; DIAGNOSTIC-ACCURACY; BLOOD-FLOW; HEART; SAFETY;
D O I
10.1097/CRD.0b013e3182613db6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Myocardial perfusion imaging is a well-established noninvasive modality for the diagnosis and prognosis of coronary artery disease. The pharmacologic stress agents adenosine and dipyridamole are widely used in imaging studies, but cause undesirable side effects, like atrioventricular block and bronchospasm, due to their nonselective adenosine receptor activation. Furthermore, the mode of administration of these agents as a bolus infusion is less preferred. Regadenoson, an A(2A) adenosine receptor selective pharmacologic stress agent was approved in 2008 and is widely used instead of adenosine and dipyridamole. This article reviews regadenosons structure, mechanism of action, advantages over adenosine and dipyridamole, and its role in various patient populations undergoing stress perfusion imaging. Emerging applications where regadenoson could be of potential use are also explored.
引用
收藏
页码:42 / 48
页数:7
相关论文
共 50 条
  • [1] Regadenoson for myocardial perfusion imaging: Is it safe?
    Hage, Fadi G.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (05) : 871 - 876
  • [2] Regadenoson for myocardial perfusion imaging: Is it safe?
    Fadi G. Hage
    Journal of Nuclear Cardiology, 2014, 21 : 871 - 876
  • [3] Regadenoson stress for myocardial perfusion imaging
    Reyes, Eliana
    FUTURE CARDIOLOGY, 2016, 12 (01) : 59 - 67
  • [4] Regadenoson safety and tolerability in myocardial perfusion imaging
    Catalano, M.
    Annunziata, G.
    Sasso, A.
    Gottilla, R.
    Scala, D.
    Ippolito, V.
    Valenti, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S516 - S516
  • [5] The prognostic value of regadenoson myocardial perfusion imaging
    Fadi G. Hage
    Gopal Ghimire
    Davis Lester
    Joshua Mckay
    Steven Bleich
    Stephanie El-Hajj
    Ami E. Iskandrian
    Journal of Nuclear Cardiology, 2015, 22 : 1214 - 1221
  • [6] Erratum to: Regadenoson for myocardial perfusion imaging: Is it safe?
    Fadi G. Hage
    Journal of Nuclear Cardiology, 2014, 21 : 1266 - 1266
  • [7] The prognostic value of regadenoson myocardial perfusion imaging
    Hage, Fadi G.
    Ghimire, Gopal
    Lester, Davis
    Mckay, Joshua
    Bleich, Steven
    El-Hajj, Stephanie
    Iskandrian, Ami E.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (06) : 1214 - 1221
  • [8] Acute Myocardial Infarction During Regadenoson Myocardial Perfusion Imaging
    Shah, Sachil
    Parra, David
    Rosenstein, Robert S.
    PHARMACOTHERAPY, 2013, 33 (06): : e90 - e95
  • [9] Safety and efficacy of Regadenoson in myocardial perfusion imaging (MPI) stress tests: A review
    Ahmed, Ambereen
    QUANTITATIVE PHASE IMAGING IV, 2018, 10503
  • [10] Seizure: An Adverse Effect of Regadenoson in Myocardial Perfusion Imaging
    Radwan, Sohab S.
    Schwartz, Owen G.
    CASE REPORTS IN CARDIOLOGY, 2019, 2019