Longitudinal Strain by Speckle Tracking Echocardiography in Pediatric Heart Transplant Recipients

被引:25
|
作者
Buddhe, Sujatha [1 ,2 ]
Richmond, Marc E. [1 ]
Gilbreth, John [1 ]
Lai, Wyman W. [1 ]
机构
[1] Columbia Univ, Med Ctr, New York Presbyterian, Morgan Stanley Childrens Hosp, New York, NY USA
[2] Seattle Childrens Hosp, Div Pediat Cardiol, Seattle, WA 98105 USA
关键词
Strain; Strain Rate; Systolic Function; Diastolic Function; Pediatrics; Transplant; VENTRICULAR DIASTOLIC DYSFUNCTION; CORONARY-ARTERY-DISEASE; REGIONAL WALL-MOTION; MYOCARDIAL-FUNCTION; ULTRASONIC STRAIN; EJECTION FRACTION;
D O I
10.1111/chd.12263
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionHeart transplant recipients are at risk for developing left ventricular (LV) dysfunction. While traditional echocardiographic parameters have limitations, speckle tracking echocardiography (STE) is a novel technique shown to be more sensitive and accurate in adult studies for evaluating ventricular systolic and diastolic function. DesignPediatric heart transplant recipients undergoing routine cardiac catheterization were included. Ratio of mitral early diastolic velocity-to-strain rate during early LV filling (E/SRE) and global longitudinal peak systolic strain (GLPSS) was measured by STE imaging. These were compared with wedge pressures by catheterization and traditional echocardiographic parameters. ResultsA total of 50 subjects (46% males) were included. Mean age of the subjects was 13.0 6.3 years and time since transplant was 4.1 years (range 0.2-17.1 years). While peak mitral inflow to late diastolic velocity (E/A ratio) was the only traditional diastolic function parameter having significant correlation with pulmonary capillary wedge pressure (PCWP) (r = 0.3; P = .3), STE-derived E/SRE had modest correlation with PCWP (r = 0.55; P < .01). Also, while most traditional systolic function parameters were normal, 12 subjects (24%) had GLPSS > -18%. Interestingly, subjects with coronary artery disease (n = 6) had significantly higher E/SRE (71.9 +/- 28.4) compared to subjects without (45.2 +/- 10.8; P < .001). ConclusionDiastolic function parameters by STE imaging correlate better with gold standard PCWP measurement than traditional echocardiographic parameters. Also, utilizing STE, abnormalities of longitudinal LV systolic function may be more common than previously thought in pediatric heart transplant recipients without acute graft rejection, despite normal systolic function by traditional echocardiogram.
引用
收藏
页码:362 / 370
页数:9
相关论文
共 50 条
  • [1] GLOBAL LONGITUDINAL STRAIN BY SPECKLE TRACKING ECHOCARDIOGRAPHY IN SUBCLINICAL ORTHOTOPIC HEART TRANSPLANT REJECTION
    Mancuso, Filippo
    Fontana, Alessandra
    Messina, Margaret
    Cipriani, Manlio
    De Gregorio, Cesare
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24
  • [2] LEFT VENTRICULAR LONGITUDINAL STRAIN BY SPECKLE-TRACKING ECHOCARDIOGRAPHY FOR THE DETECTION OF TREATMENT-REQUIRING REJECTION IN CLINICALLY ASYMPTOMATIC HEART TRANSPLANT RECIPIENTS
    Sera, Fusako
    Kato, Tomoko S.
    Farr, MaryJane
    Kitada, Shuichi
    Russo, Cesare
    Di Tullio, Marco
    Mancini, Donna
    Homma, Shunichi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1028 - E1028
  • [3] Two-dimensional speckle tracking strain echocardiography in heart transplant patients
    Syeda, B.
    Hoefer, P.
    Pichler, P.
    Vertesich, M.
    Roedler, S.
    Mahr, S.
    Graf, S.
    Bergler-Klein, J.
    Glogar, D.
    Binder, T.
    EUROPEAN HEART JOURNAL, 2009, 30 : 345 - 345
  • [4] SUBCLINICAL CARDIOVASCULAR DAMAGE IN PEDIATRIC KIDNEY TRANSPLANT RECIPIENTS: CARDIAC STRAIN MEASUREMENTS BY TWO DIMENSIONAL SPECKLE TRACKING ECHOCARDIOGRAPHY
    Barczi, Adrienn
    Lakatos, Balint
    Cseprekal, Orsolya
    Kis, EVa
    Kovacs, Attila
    Berta, Laszlo
    Szabo, Attila
    Merkely, Bela
    Reusz, Gyorgy S.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34
  • [5] Use of of Two Dimensional Speckle Tracking Echocardiography for the Detection of Acute Rejection in Pediatric Heart Transplant Recipients: A Prospective Study
    Engelhardt, K.
    Sorenson, M.
    Das, B.
    Zellers, T.
    Lemler, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S104 - S104
  • [6] Longitudinal strain by speckle tracking echocardiography in constrictive pericarditis
    Jottrand, Edith
    Serste, Thomas
    Mulkay, Jean-Pierre
    Vandueren, Charlotte
    Unger, Philippe
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (06) : 638 - 638
  • [7] GLOBAL LONGITUDINAL ECHOCARDIOGRAPHIC STRAIN IMAGING IN PEDIATRIC HEART TRANSPLANT RECIPIENTS
    Wisotzkey, Bethany L.
    Albers, Erin
    Kemna, Mariska
    Law, Yuk
    Boucek, Robert
    Kronmal, Richard
    Jorgensen, Neal
    Bhat, Aarti
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1224 - A1224
  • [8] Subclinical cardiac dysfunction in pediatric kidney transplant recipients identified by speckle-tracking echocardiography
    Barczi, Adrienn
    Lakatos, Balint Karoly
    Szilagyi, Monika
    Kis, Eva
    Cseprekal, Orsolya
    Fabian, Alexandra
    Kovacs, Attila
    Szabo, Attila J.
    Merkely, Bela
    Salvi, Paolo
    Reusz, Gyorgy S.
    PEDIATRIC NEPHROLOGY, 2022, 37 (10) : 2489 - 2501
  • [9] Subclinical cardiac dysfunction in pediatric kidney transplant recipients identified by speckle-tracking echocardiography
    Adrienn Bárczi
    Bálint Károly Lakatos
    Mónika Szilágyi
    Éva Kis
    Orsolya Cseprekál
    Alexandra Fábián
    Attila Kovács
    Attila J. Szabó
    Béla Merkely
    Paolo Salvi
    György S. Reusz
    Pediatric Nephrology, 2022, 37 : 2489 - 2501
  • [10] Subclinical cardiac dysfunction in pediatric kidney transplant recipients: Cardiac strain measurements by two-dimensional speckle tracking echocardiography
    Barczi, Adrienn
    Lakatos, Balint
    Vegh, Anna
    Kis, Eva
    Cseprekal, Orsolya
    Fabian, Alexandra
    Kovacs, Attila
    Szabo, Attila J.
    Merkely, Bela
    Salvi, Paolo
    Reusz, Gyorgy S.
    PEDIATRIC TRANSPLANTATION, 2022, 26