Experimental study on single bubble growth under subcooled, saturated, and superheated nucleate pool boiling

被引:2
|
作者
Kim, Jeongbae
Lee, Jangho
Kim, Moo Hwan
机构
[1] Pohang Univ Sci & Technol, Dept Mech Engn, Pohang 790784, Kyoungbuk Do, South Korea
[2] KIER, New & Renewable Energy Res Dept, Taejon 305343, South Korea
[3] Kunsan Natl Univ, Dept Mech Engn, Kunsan 573701, Jellabuk Do, South Korea
关键词
pool temperature; constant wall temperature; single bubble growth; nucleate pool boiling; microscale heater array;
D O I
10.1007/BF02915987
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Nucleate pool boiling experiments with constant wall temperature were performed using pure R113 for subcooled, saturated, and superheated pool conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain the constant wall temperature and to measure the instantaneous heat flow rate accurately with high temporal and spatial resolutions. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble geometry was obtained from the captured bubble images. The effect of the pool conditions on the bubble growth behavior was analyzed using dimensionless parameters for the initial and thermal growth regions. The effect of the pool conditions on the heat flow rate behavior was also examined. This study will provide good experimental data with precise constant wall temperature boundary condition for such works.