A Glucose Biosensor Based on Immobilization of Glucose Oxidase into 3D Macroporous TiO2

被引:46
|
作者
Cao, Huimin [1 ]
Zhu, Yihua [1 ]
Tang, Longhua [1 ]
Yang, Xiaoling [1 ]
Li, Chunzhong [1 ]
机构
[1] E China Univ Sci & Technol, Sch Mat Sci & Engn, Minist Educ, Key Lab Ultrafine Mat, Shanghai 200237, Peoples R China
基金
中国国家自然科学基金;
关键词
Macroporous materials; Titania; Glucose oxidase; Inverse opals; Michaelis-Menten constant; Biosensors;
D O I
10.1002/elan.200804314
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
3D macroporous TiO2 inverse opals have been derived from a sol-gel procedure using polystyrene colloidal crystals as templates. EDS and SEM showed a face-centered cubic (FCC) structure TiO2 inverse opal was obtained. Glucose oxidase (GOx) was successfully immobilized on the surface of indium-tin oxide (ITO) electrode modified by TiO2 inverse opal (TiO2(IO)). Electrochemical properties of GOx/TiO2(IO)/ITO electrode were characterized by using the three electrodes system. The result of cyclic voltammetry showed that a couple of stable and well-defined redox peaks for the direct electron transfer of GOx in absence of glucose, and the redox peak height enhanced in presence of 0.1 mu M glucose. Compare with the ordinary structured GOx/TiO2/ITO electrode, inverse opal structured GOx/TiO2(IO)/ITO electrode has a better respond to the glucose concentration change. Under optimized experimental conditions of solution pH 6.8 and detection potential at 0.30 V versus saturated calomel electrode (SCE), amperometric measurements were performed. The sensitivity and the detection limit of glucose detection was 151 mu A cm(-2) mM(-1) and 0.02 mu M at a signal-to-noise ratio of 3, respectively. The good response was due to the good biocompatibility of TiO2 and the large effective surface of the three-dimensionally ordered macroporous structure.
引用
收藏
页码:2223 / 2228
页数:6
相关论文
共 50 条
  • [1] Glucose biosensor based on glucose oxidase immobilized on branched TiO2 nanorod arrays
    Liu, S.
    Fu, D.
    ADVANCES IN ENERGY AND ENVIRONMENT RESEARCH, 2017, : 195 - 198
  • [2] Glucose Biosensor Based on Glucose Oxidase Immobilized on Multi-Vacancy TiO2 Nanotube Arrays
    Hu, Zhitong
    Rong, Ju
    Zhan, Zhaolin
    Yu, Xiaohua
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (10): : 9661 - 9670
  • [3] Photoelectrochemical Glucose Biosensor Based on the Heterogeneous Facets of Nanocrystalline TiO2/Au/Glucose Oxidase Films
    Yang, Wenke
    Xu, Wei
    Wang, Yadong
    Chen, Delun
    Wang, Xiaohong
    Cao, Yang
    Wu, Qiang
    Tu, Jinchun
    Zhen, Chao
    ACS APPLIED NANO MATERIALS, 2020, 3 (03): : 2723 - 2732
  • [4] One step immobilization of glucose oxidase on TiO2 nanotubes towards glucose biosensing
    Varkani, Reza Akhbari
    Rafiee-Pour, Hossain-Ali
    Noormohammadi, Mohammad
    MICROCHEMICAL JOURNAL, 2021, 170
  • [5] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes
    Kong, Tao
    Chen, Yang
    Ye, Yiping
    Zhang, Kun
    Wang, Zhenxing
    Wang, Xiaoping
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 344 - 350
  • [6] A glucose biosensor based on immobilization of glucose oxidase in chitosan network matrix
    Yao, H
    Li, N
    Xu, JZ
    Zhu, JJ
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (03) : 275 - 279
  • [7] A glucose biosensor based on the immobilization of glucose oxidase and Au nanocomposites with polynorepinephrine
    Liu, Yang
    Nan, Xu
    Shi, Wei
    Liu, Xin
    He, Zi
    Sun, Yanan
    Ge, Dongtao
    RSC ADVANCES, 2019, 9 (29) : 16439 - 16446
  • [8] Determination of Glucose with Biosensor by Immobilization of Glucose Oxidase with Chitosan
    Zhang Yan
    Nan Cai-Feng
    Feng Li
    Zhang Li-Qin
    Dong Chuan
    Shuang Shao-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (07) : 1049 - 1052
  • [9] Glucose Biosensor Based on Immobilization of Glucose Oxidase on Porous Screen Printed Electrodes
    Bian, Li-Jun
    Wang, Lu
    Ye, Yin-Jian
    Liu, Xiao-Xia
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (07): : 6201 - 6210
  • [10] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the CuGeO3 nanowire modified electrode
    Yong Ping Dong
    Li Huang
    Xiang Feng Chu
    Li Zhai Pei
    Russian Journal of Electrochemistry, 2013, 49 : 571 - 576