Pneumatic tube transport of platelet concentrates does not affect in vitro platelet function

被引:0
|
作者
Henskens, Y. [1 ]
Lance, M. [2 ]
Van Oerle, R. [1 ]
Theunissen, M. [2 ]
Marcus, M. [2 ]
机构
[1] Acad Med Ctr Maastricht, Hematol Lab, Maastricht, Netherlands
[2] Acad Med Ctr Maastricht, Maastricht, Netherlands
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
P-WE-101
引用
收藏
页码:552 / 552
页数:1
相关论文
共 50 条
  • [1] Volume reduction of stored platelet concentrates does not affect in vitro platelet responses.
    Rand, ML
    He, L
    AlMusa, A
    Carcao, MD
    Lau, W
    Weitzman, S
    Freedman, J
    Blanchette, VS
    BLOOD, 1997, 90 (10) : 3329 - 3329
  • [2] Platelet concentrate transport in pneumatic tube systems - does it work?
    Lance, M. D.
    Marcus, M. A. E.
    van Oerle, R.
    Theunissen, H. M. S.
    Henskens, Y. M. C.
    VOX SANGUINIS, 2012, 103 (01) : 79 - 82
  • [3] Volume reduction of pre-storage leukoreduced platelet concentrates does not affect platelet function in vitro or platelet recovery in vivo.
    Rand, ML
    Blanchette, VS
    Weitzman, S
    Lau, W
    Clark, D
    Wakefield, CD
    Freedman, J
    BLOOD, 2001, 98 (11) : 58A - 59A
  • [4] Lenalidomide does not affect platelet function in vitro
    Li, Panpan
    Xu, Jiadai
    Wang, Yawen
    Liu, Peng
    CLINICAL LYMPHOMA MYELOMA & LEUKEMIA, 2022, 22 : S50 - S51
  • [5] Xenon does not affect human platelet function in vitro
    de Rossi, LW
    Horn, NA
    Baumert, JH
    Gutensohn, K
    Hutschenreuter, G
    Rossaint, R
    ANESTHESIA AND ANALGESIA, 2001, 93 (03): : 635 - 640
  • [6] Pneumatic tube transport affects platelet function measured by multiplate electrode aggregometry
    Thalen, Simon
    Forsling, Ida
    Eintrei, Jaak
    Soderblom, Lisbeth
    Antovic, Jovan P.
    THROMBOSIS RESEARCH, 2013, 132 (01) : 77 - 80
  • [7] The impact of pneumatic tube transport on whole blood coagulation and platelet function assays
    Nissen, Peter H.
    Wulff, Dorte E.
    Torring, Niels
    Hvas, Anne-Mette
    PLATELETS, 2018, 29 (04) : 421 - 424
  • [8] Pneumatic tube transport affects platelet function measured by multiplate electrode aggregometry
    Simon, T.
    Forsling, I
    Eintrei, J.
    Soderblom, L.
    Antovic, J. P.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 512 - 512
  • [9] Platelet function in stored platelet concentrates
    Bunescu, A
    Lundahl, J
    Egberg, N
    THROMBOSIS AND HAEMOSTASIS, 1997, : PS313 - PS313
  • [10] Pneumatic tube transport of blood samples affects global hemostasis and platelet function assays
    Lorenzen, Henriette
    Frostrup, Ann-Britt
    Larsen, Anja S.
    Fenger, Michelle S.
    Dahdouh, Sanne
    Zoel-Ghina, Randa
    Nielsen, Leif K.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (05) : 1207 - 1215