Measurement of Defibrillator Surface Potentials for Simulation Verification

被引:0
|
作者
Tate, Jess D. [1 ]
Stinstra, Jeroen G. [2 ]
Pilcher, Thomas A. [2 ]
MacLeod, Rob S. [3 ]
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT 84112 USA
[3] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite the growing use of implantable cardioverter defibrillators (ICDs) in adults and children, there has been little progress in optimizing device and electrode placement. To facilitate effective placement of ICDs, especially in pediatric cases, we have developed a predictive model that evaluates the efficacy of a delivered shock. Most recently, we have also developed an experimental validation approach based on measurements from clinical cases. The approach involves obtaining body surface potential maps of ICD discharges during implantation surgery and comparing these measured potentials with simulated surface potentials to determine simulation accuracy. Comparison of the simulated and measured potentials yielded very similar patterns and a typical correlation greater than 0.9, suggesting that the predictive simulation generates realistic potential values. Ongoing sensitivity studies will determine the robustness of the results and pave the way for use of this approach for assisting optimization of ICD use.
引用
收藏
页码:853 / 856
页数:4
相关论文
共 50 条
  • [1] Measuring Defibrillator Surface Potentials for Simulation Verification
    Tate, Jess
    Stinstra, Jeroen
    Pilcher, Thomas
    Poursaid, Ahrash
    Saarel, Elizabeth
    MacLeod, Rob
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 239 - 242
  • [2] Simulation and Verification of Three-Dimensional Shape Measurement Method for Composite Surface
    Guo Zhinan
    Liu Xiaohong
    Zhang Zonghua
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (19)
  • [3] Body surface potentials during discharge of the implantable cardioverter defibrillator
    Peters, W
    Kowallik, P
    Reisberg, M
    Meesmann, M
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (05) : 491 - 497
  • [4] Electroacoustic measurement of surface potentials
    Herbig, R
    Bräunig, RE
    Tomandl, G
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2003, 222 (1-3) : 79 - 85
  • [5] MEASUREMENT OF SURFACE-POTENTIALS
    NOBLET, A
    RIDELAIRE, H
    SYLIN, G
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (03): : 234 - 239
  • [6] Measuring defibrillator surface potentials: The validation of a predictive defibrillation computer model
    Tate, Jess
    Stinstra, Jeroen
    Pilcher, Thomas
    Poursaid, Ahrash
    Jolley, Matthew A.
    Saarel, Elizabeth
    Triedman, John
    MacLeo, Rob S.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 102 : 402 - 410
  • [7] ELECTROSTATIC VOLTMETER FOR MEASUREMENT OF SURFACE POTENTIALS
    ASHCRAFT, TL
    HACKERMAN, N
    RINEY, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1963, 34 (01): : 5 - &
  • [8] MEASUREMENT AND CONTROL OF MICROSCOPIC SURFACE POTENTIALS
    CRAWFORD, CK
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (07): : 777 - &
  • [9] SURFACE POTENTIALS AND THEIR MEASUREMENT BY DIODE METHOD
    KNAPP, AG
    SURFACE SCIENCE, 1973, 34 (02) : 289 - 316
  • [10] Verification of simulation of surface texturing on planar surface by grinding
    Ho-Chan Kim
    Tae Jo Ko
    International Journal of Precision Engineering and Manufacturing, 2015, 16 : 225 - 231