An energy transfer method for 4D Monte Carlo dose calculation

被引:40
|
作者
Siebers, Jeffrey V. [1 ]
Zhong, Hualiang [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
four dimensional therapy; Monte Carlo; dose mapping;
D O I
10.1118/1.2968215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article presents a new method for four-dimensional Monte Carlo dose calculations which properly addresses dose mapping for deforming anatomy. The method, called the energy transfer method (ETM), separates the particle transport and particle scoring geometries: Particle transport takes place in the typical rectilinear coordinate system of the source image, while energy deposition scoring takes place in a desired reference image via use of deformable image registration. Dose is the energy deposited per unit mass in the reference image. ETM has been implemented into DOSXYZnrc and compared with a conventional dose interpolation method (DIM) on deformable phantoms. For voxels whose contents merge in the deforming phantom, the doses calculated by ETM are exactly the same as an analytical solution, contrasting to the DIM which has an average 1.1% dose discrepancy in the beam direction with a maximum error of 24.9% found in the penumbra of a 6 MV beam. The DIM error observed persists even if voxel subdivision is used. The ETM is computationally efficient and will be useful for 4D dose addition and benchmarking alternative 4D dose addition algorithms. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4096 / 4105
页数:10
相关论文
共 50 条
  • [1] A 4D Monte Carlo Dose Calculation Method for Clinical Applications
    Zhong, H.
    Weiss, E.
    Rosu, M.
    Keall, P.
    Williamson, J.
    Siebers, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [2] Investigation of Dose Interpolation Errors with a 4D Monte Carlo Method
    Zhong, H.
    Siebers, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] 4D MIMVista Workflow Vs 4D Dose Calculations Based On a Monte Carlo Method
    Valdes, G.
    Iwamoto, K.
    Lee, P.
    Low, D.
    Robinson, C.
    Lamb, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] A new DOSXYZnrc method for Monte Carlo simulations of 4D dose distributions
    Su, S.
    Atwal, P.
    Lobo, J.
    Duzenli, C.
    Popescu, I. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (24):
  • [5] Monte Carlo dose calculation procedure using a 4D motion simulating chest model
    Zhang, J.
    Xu, X. George
    Shi, C.
    Fuss, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2294 - 2294
  • [6] Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer
    Matsugi K.
    Nakamura M.
    Miyabe Y.
    Yamauchi C.
    Matsuo Y.
    Mizowaki T.
    Hiraoka M.
    Radiological Physics and Technology, 2013, 6 (1) : 233 - 240
  • [7] Fast 4D Monte Carlo Dose Calculations in Deforming Anatomies
    Heath, E.
    Kawrakow, I.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [8] A comparison of dose warping methods for 4D Monte Carlo dose calculations in lung
    Heath, E.
    Seco, J.
    Wu, Z.
    Sharp, G. C.
    Paganetti, H.
    Seuntjens, J.
    INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [9] Continuously Deforming 4D Voxel Phantom for Realistic Representation of Respiratory Motion in Monte Carlo Dose Calculation
    Han, Min Cheol
    Seo, Jeong Min
    Lee, Se Hyung
    Kim, Chan Hyeong
    Yeom, Yeon Soo
    Thang Tat Nguyen
    Choi, Chansoo
    Kim, Seonghoon
    Jeong, Jong Hwi
    Sohn, Jason W.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (06) : 2918 - 2924
  • [10] A Framework for 4D and Adaptive Planning Workflow Incorporating Monte Carlo-Based Optimization and Dose Calculation
    Zhong, H.
    Stanley, N.
    Chetty, I.
    MEDICAL PHYSICS, 2011, 38 (06)