Efficient Ratiometric Fluorescence Probe Based on Dual-Emission Quantum Dots Hybrid for On-Site Determination of Copper Ions

被引:262
|
作者
Yao, Jianlei [1 ]
Zhang, Kui [2 ]
Zhu, Houjuan [1 ]
Ma, Fang [1 ]
Sun, Mingtai [2 ]
Yu, Huan [2 ]
Sun, Jian [1 ]
Wang, Suhua [1 ,2 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
[2] Chinese Acad Sci, Inst Intelligent Machines, Hefei 230031, Anhui, Peoples R China
关键词
AQUEOUS-SOLUTION; OXYGEN SENSORS; LIVING CELLS; ENERGY-TRANSFER; METAL-IONS; IN-VITRO; DESIGN; VISUALIZATION; CHEMOSENSORS; CU2+;
D O I
10.1021/ac401011r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Of various chemosensory protocols, the color change observed by the naked eye is considered to be a conceivable and on-site way to indicate the presence of an analyte. We herein designed a ratiometric fluorescence probe by hybridizing dual-emission quantum dots (QDs) and demonstrated its efficiency for on-site visual determination of copper ions. The hybrid probe comprises two sizes of cadmium telluride QDs emitting red and green fluorescence, respectively, in which the red-emitting ones are embedded in silica nanoparticles and the green emitting ones are covalently linked onto the surface. The fluorescence of the embedded QDs is insensitive to the analyte, whereas the green emissive QDs are functionalized to be selectively quenched by the analyte. Upon exposure to different amounts of copper ions, the variations of the dual emission intensity ratios display continuous color changes from green to red, which can be clearly observed by the naked eye. The limit of detection for copper is estimated to be 1.1 nM, much lower than the allowable level of copper (similar to 20 mu M) in drinking water set by U.S. Environmental Protection Agency. The probe is demonstrated for the determination of copper ions in lake water and mineral water samples, especially for visually monitoring copper residues on herb leaves. This prototype ratiometric probe is simple, fully self-contained, and thus potentially attractive for visual identification without the need for elaborate equipment.
引用
收藏
页码:6461 / 6468
页数:8
相关论文
共 50 条
  • [1] Ratiometric fluorescence molecularly imprinted sensor based on dual-emission quantum dots hybrid for determination of tetracycline
    Xiao Wei
    Hui Chen
    [J]. Analytical and Bioanalytical Chemistry, 2019, 411 : 5809 - 5816
  • [2] Ratiometric fluorescence molecularly imprinted sensor based on dual-emission quantum dots hybrid for determination of tetracycline
    Wei, Xiao
    Chen, Hui
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (22) : 5809 - 5816
  • [3] Highly sensitive and novel dual-emission fluorescence nanosensor utilizing hybrid carbon dots-quantum dots for ratiometric determination of chlorpromazine
    Narimani, Saeedeh
    Samadi, Naser
    Delnavaz, Elnaz
    [J]. ANALYTICAL SCIENCES, 2024, 40 (08) : 1521 - 1528
  • [4] A novel ratiometric fluorescent probe for detection of iron ions and zinc ions based on dual-emission carbon dots
    Wang, Yulin
    Lao, Siyuan
    Ding, Weijie
    Zhang, Zhenda
    Liu, Siyu
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 284 : 186 - 192
  • [5] Dual-emission ratiometric fluorescence probe based on copper nanoclusters for the detection of rutin and picric acid
    Lin, Qing
    Chu, Hongtao
    Chen, Jiaqi
    Gao, Lidi
    Zong, Wei
    Han, Shuang
    Li, Jinlong
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 270
  • [6] Centrifugated lateral flow assay strips based on dual-emission carbon dots modified with europium ions for ratiometric determination and on-site discrimination of tetracyclines in environment
    Hu, Houwen
    Xing, Haoming
    Zhang, Yihao
    Liu, Xinru
    Gao, Sineng
    Wang, Linfan
    Li, Tingting
    Zhang, Ting
    Chen, Da
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 951
  • [7] Surface modification and ratiometric fluorescence dual function enhancement for visual and fluorescent detection of glucose based on dual-emission quantum dots hybrid
    Hao, Tongfan
    Wei, Xiao
    Nie, Yijing
    Xu, Yeqing
    Lu, Kai
    Yan, Yongsheng
    Zhou, Zhiping
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 : 70 - 76
  • [8] Instant Visual Detection of Trinitrotoluene Particulates on Various Surfaces by Ratiometric Fluorescence of Dual-Emission Quantum Dots Hybrid
    Zhang, Kui
    Zhou, Haibo
    Mei, Qingsong
    Wang, Suhua
    Guan, Guijian
    Liu, Renyong
    Zhang, Jian
    Zhang, Zhongping
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (22) : 8424 - 8427
  • [9] Dual-emission ratiometric fluorescent detection of dinotefuran based on sulfur-doped carbon quantum dots and copper nanocluster hybrid
    Yang, Yue
    Wei, Qunyan
    Zou, Tong
    Kong, Yulin
    Su, Linfeng
    Ma, Dian
    Wang, Yude
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2020, 321
  • [10] Ratiometric fluorescence probe based on monochromatic dual-emission carbon nanodots with fluorescence spectral change
    Molla, Aniruddha
    Lee, Hyein
    Ju, Youngwon
    Choi, Jeongyun
    Kim, Joohoon
    [J]. DYES AND PIGMENTS, 2022, 197