A method toaccount for trackoverlap in CR-39 detectors

被引:8
|
作者
Franci, Daniele [1 ]
Aureli, Tommaso [1 ]
机构
[1] ARPA Lazio, Dept Rome, I-00100 Rome, Italy
关键词
D O I
10.1093/rpd/nct193
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solid-state nuclear track detectors are commonly used for the detection of indoor radon levels. However, despite numerous advantages, this technique still presents many unsolved problems. An important source of error is represented by the reduction in the detection efficiency due to overlapping tracks, which results in a sensible underestimation of the radon levels. This paper presents a new experimental procedure to address the effect of overlapping tracks by establishing a relationship between the detection efficiency and the number of detected tracks. Experimental data have been collected at the radon chamber of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), at the ENEA centre in Casaccia, using CR-39 detectors provided by Radosys Ltd. It has been proved that the method, applied to the experimental settings of this study, gives reliable results up to 7607 kBq h m(3). Finally, the method has been validated through a Monte Carlo simulation, exploring a wide range of radon exposure.
引用
收藏
页码:107 / 110
页数:4
相关论文
共 50 条
  • [1] A better understanding of the background of CR-39 detectors
    Mishra, R
    Orlando, C
    Tommasino, L
    Tonnarini, S
    Trevisi, R
    RADIATION MEASUREMENTS, 2005, 40 (2-6) : 325 - 328
  • [2] The Use of CR-39 Detectors in LENR Experiments
    Mosier-Boss, P. A.
    Forsley, L. P. G.
    McDaniel, P. J.
    JOURNAL OF CONDENSED MATTER NUCLEAR SCIENCE, 2014, 14 : 29 - 49
  • [3] Response of electrochemically etched CR-39 detectors to protons
    Dörschel, B
    Hermsdorf, D
    Kadner, K
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 137 - 140
  • [4] PROSPECTING OIL AND GAS DEPOSITS WITH CR-39 DETECTORS
    LU, ZH
    WANG, YJ
    CHEN, DR
    LI, YM
    XU, AU
    YANG, FX
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 387 - 392
  • [5] On the detecting ability of the CR-39 track detectors in vacuum
    OIYaI, Dubna, Russia
    Pribory i Tekhnika Eksperimenta, 1997, (04): : 12 - 15
  • [6] Electrochemical etching of CR-39 detectors at low temperature
    Dajko, G
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D393 - D393
  • [7] SENSITIVITY STUDY OF CR-39 PLASTIC TRACK DETECTORS
    HE, YD
    PRICE, PB
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (03): : 491 - 494
  • [8] An extended study of the etching characteristics of CR-39 detectors
    Leonardi, F.
    Caresana, M.
    D'Alessandro, M.
    Mishra, R.
    Tonnarini, S.
    Trevisi, R.
    Veschetti, M.
    RADIATION MEASUREMENTS, 2009, 44 (9-10) : 787 - 790
  • [9] Sensitivity study of CR-39 plastic track detectors
    He, Y.D.
    Price, P.B.
    Nuclear Tracks and Radiation Measurements, 1992, 20 (03): : 491 - 494
  • [10] PLATE-OUT EFFECTS IN CR-39 DETECTORS
    WONG, CF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (01): : 254 - 256