Reproducibility of joint space width and the intermargin distance measurements in patients with medial osteoarthritis of the knee in various degrees of flexion

被引:7
|
作者
Takahashi, Toshiaki [1 ]
Yamanaka, Norio [2 ]
Ikeuchi, Masahiko [2 ]
Yamamoto, Haruyasu [1 ]
机构
[1] Ehime Univ, Dept Bone & Joint Surg, Grad Sch Med, Toon, Ehime 7910295, Japan
[2] Kochi Univ, Kochi Med Sch, Dept Orthopaed, Nanko Ku, Kochi 7838505, Japan
关键词
Joint space width; Osteoarthritis; Knee; Reproducibility; Radiograph; WEIGHT-BEARING RADIOGRAPH; STANDING ANTEROPOSTERIOR; AUTOMATED MEASUREMENTS; ARTICULAR-CARTILAGE; SEMIFLEXED MTP; FIELD-TEST; MRI; METATARSOPHALANGEAL; COMPARTMENT; PROGRESSION;
D O I
10.1007/s00256-008-0572-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study tested the variability and reproducibility of measurements of the joint space width (JSW) and intermargin distance (IMD) of the medial tibial plateau in specific positions of knee flexion in osteoarthritic knees in order to evaluate the most useful knee angle for radiographic measurements. Radiographs from 56 knees with osteoarthritis from 46 patients were taken with the knees in conventional full extension and 15, 30 and 45 of flexion with weight bearing. Three orthopedic surgeons independently measured the JSW and IMD at the narrowest point and the midpoint of medial tibial plateau using a computer-assisted method. The JSW and IMD were smallest at 15 flexion, both measured at the narrowest point and the midpoint of the medial compartment. Reproducibility of the IMD at the midpoint was better than at the narrowest point for all four flexion angles. Measurements of the medial JSW and IMD are smallest at 15 of knee flexion indicating that radiographs should be obtained at this angle in order to best demonstrate the extent of osteoarthritis.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [1] Reproducibility of joint space width and the intermargin distance measurements in patients with medial osteoarthritis of the knee in various degrees of flexion
    Toshiaki Takahashi
    Norio Yamanaka
    Masahiko Ikeuchi
    Haruyasu Yamamoto
    [J]. Skeletal Radiology, 2009, 38 : 37 - 42
  • [2] Validation of the Longitudinal Reproducibility of Medial Joint Space Width Quantification in Knee Osteoarthritis
    Goker, Berna
    Akalin, Tayfun
    Block, Joel A.
    [J]. ARTHRITIS AND RHEUMATISM, 2011, 63 (10): : S779 - S779
  • [3] Fixed-flexion radiography of the knee provides reproducible joint space width measurements in osteoarthritis
    Manish Kothari
    Ali Guermazi
    Gabriele von Ingersleben
    Yves Miaux
    Martine Sieffert
    Jon E. Block
    Randall Stevens
    Charles G. Peterfy
    [J]. European Radiology, 2004, 14 : 1568 - 1573
  • [4] Fixed-flexion radiography of the knee provides reproducible joint space width measurements in osteoarthritis
    Kothari, M
    Guermazi, A
    von Ingersleben, G
    Miaux, Y
    Sieffert, M
    Block, JE
    Stevens, R
    Peterfy, CG
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (09) : 1568 - 1573
  • [5] Obesity related measurements and joint space width in patients with knee osteoarthritis
    Çimen, OB
    Incel, NA
    Yapici, Y
    Apaydin, D
    Erdogan, C
    [J]. UPSALA JOURNAL OF MEDICAL SCIENCES, 2004, 109 (02) : 159 - 164
  • [6] Reproducibility of the semiflexed (metatarsophalangeal) radiographic knee position and automated measurements of medial tibiofemoral joint space width in a multicenter clinical trial of knee osteoarthritis
    Buckland-Wright, JC
    Ward, RJ
    Peterfy, C
    Mojcik, CF
    Leff, RL
    [J]. JOURNAL OF RHEUMATOLOGY, 2004, 31 (08) : 1588 - 1597
  • [7] Effects of Knee Flexion on Minimal Joint Space Width Increase in Knee Osteoarthritis Patients in the IMI-APPROACH cohort
    Bax, Eva
    Nguyen, Chien
    Custers, Roel J.
    van Egmond, Nienke
    Arbabi, Vahid
    Rayegan, Hassan
    Gielis, Willem Paul
    Lindner, Claudia
    Cootes, Tim
    Kloppenburg, Margreet
    Blanco-Garcia, Francisco J.
    Haugen, Ida K.
    Berenbaum, Francis
    Jansen, Mylene P.
    Mastbergen, Simon
    Wirth, Wolfgang
    Eckstein, Felix
    Weinans, Harrie
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2024, 32 (06) : 804 - 805
  • [8] X-ray technologists' reproducibility from automated measurements of the medial tibiofemoral joint space width in knee osteoarthritis for a multicenter, multinational clinical trial
    Buckland-Wright, JC
    Bird, CF
    Ritter-Hrncirik, CA
    Cline, GA
    Tonkin, C
    Hangartner, TN
    Ward, RJ
    Meyer, JM
    Meredith, MP
    [J]. JOURNAL OF RHEUMATOLOGY, 2003, 30 (02) : 329 - 338
  • [9] INFLUENCE OF BLINDING SEQUENCE OF RADIOGRAPHS ON THE REPRODUCIBILITY OF KNEE JOINT SPACE WIDTH MEASUREMENT IN OSTEOARTHRITIS
    Gensburger, D.
    Roux, J.
    Arlot, M.
    Chapurlat, R.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2009, 20 : 17 - 17
  • [10] Field test of the reproducibility of automated measurements of medial tibiofemoral joint space width derived from standardized knee radiographs
    Mazzuca, SA
    Brandt, KD
    Buckland-Wright, JC
    Buckwalter, KA
    Katz, BP
    Lynch, JA
    Ward, RJ
    Emsley, CL
    [J]. JOURNAL OF RHEUMATOLOGY, 1999, 26 (06) : 1359 - 1365