Time-dependent Seismic Performance Assessment of Corroded Reinforced Concrete Frames

被引:11
|
作者
Ghanooni-Bagha, Mohammad [1 ]
Zarei, Sajad [2 ]
Savoj, Hamid Reza [2 ]
Shayanfar, Mohsen Ali [3 ]
机构
[1] Islamic Azad Univ, Dept Civil Engn, East Tehran Branch, POB 18735-136, Tehran, Iran
[2] Iran Univ Sci & Technol, Sch Civil Engn, POB 16765-163, Tehran, Iran
[3] Iran Univ Sci & Technol, Ctr Excellence Fundamental Studies Struct Engn, POB 16765-163, Tehran, Iran
来源
关键词
RC structures; corrosion; push-over analysis; IDA analysis; seismic performance; COMPRESSIVE STRENGTH; CORROSION; RELIABILITY; REDUCTION; BEHAVIOR; BEAMS;
D O I
10.3311/PPci.12653
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, effects of reinforcement corrosion such as reinforcement cross section reduction, steel yield strength and concrete compressive strength reduction on RC member capacity decrease are studied. Next, a two-dimensional reinforced concrete moment resistant frame is modeled to evaluate the effects of moderate and severe intensity corrosion on moment-curvature behavior of elements and structure seismic response under nonlinear analysis. Structure capacity curves in push-over analysis and failure curves resulted from IDA for both the structure without and with corrosion are obtained and the effects of reinforcement's corrosion on the reinforced concrete frame seismic performance are determined through comparing the results. The results revealed that in terms of amount, place and type of corrosion in the reinforced concrete frame, value of the reduction resisting moment of elements is different. Furthermore, the outcomes of nonlinear analyses showed that the capacity of structure is reduced and its seismic performance level is changed as a result of corrosion.
引用
收藏
页码:631 / 640
页数:10
相关论文
共 50 条
  • [1] Time-dependent reliability assessment and optimal design of corroded reinforced concrete beams
    Li, Junxiang
    Guo, Xiwei
    Zhang, Xinxin
    Wu, Zijun
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2024, 27 (08) : 1313 - 1327
  • [2] Seismic Performance Assessment of Corroded Reinforced Concrete Short Columns
    Ngoc Son Vu
    Li, Bing
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (04)
  • [3] Experimental investigation on seismic performance of corroded reinforced concrete moment-resisting frames
    Liu, Xiaojuan
    Jiang, Huanjun
    He, Liusheng
    [J]. ENGINEERING STRUCTURES, 2017, 153 : 639 - 652
  • [4] Lifetime seismic performance assessment for chloride-corroded reinforced concrete buildings
    Chiu, Chien Kuo
    Tu, Feng Jun
    Hsiao, Fu Pei
    [J]. STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2015, 11 (03) : 345 - 362
  • [5] Time-dependent seismic performance of reinforced concrete member under common atmosphere environment
    Liang, Yan
    Chen, Huai
    Luo, Xiao-Yong
    [J]. Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2016, 43 (03): : 104 - 112
  • [6] Seismic performance assessment of reinforced concrete frames with different bracing systems
    Ahiwale, Dhiraj D.
    Kontoni, Denise-Penelope N.
    Darekar, Prachi L.
    [J]. INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2023, 8 (03)
  • [7] Seismic performance assessment of reinforced concrete frames with different bracing systems
    Dhiraj D. Ahiwale
    Denise-Penelope N. Kontoni
    Prachi L. Darekar
    [J]. Innovative Infrastructure Solutions, 2023, 8
  • [8] Seismic performance of reinforced corroded concrete bridge piers
    Fang, C. Q.
    Yuan, Z. J.
    Zhang, J. M.
    Zhu, J.
    [J]. BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE EXTENSION, 2014, : 253 - 260
  • [9] Time-dependent safety performance of reinforced concrete structures
    Woju, Utino Worabo
    Balu, A. S.
    [J]. JOURNAL OF ENGINEERING DESIGN AND TECHNOLOGY, 2020, 18 (05) : 1103 - 1120
  • [10] Seismic damage behavior of corroded reinforced concrete moment-resisting frames
    Liu, Xiaojuan
    Jiang, Huanjun
    Guo, Zixiong
    [J]. Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2019, 50 (06): : 1437 - 1446