The fabrication of poly (polyethylene glycol diacrylate) monolithic porous layer open tubular (mono-PLOT) columns and applications in hydrophilic interaction chromatography and capillary gas chromatography for small molecules

被引:7
|
作者
Chang, Feng [1 ]
Yue, Yunfang [1 ]
Yang, Zihui [1 ]
Huang, Si [1 ]
Liu, Zhihua [2 ]
Wang, Kunmiao [2 ]
Peng, Yan [3 ]
Chen, Yingzhuang [1 ]
Ma, Ming [1 ]
Chen, Bo [1 ]
机构
[1] Hunan Normal Univ, Key Lab Phytochem R&D Hunan Prov, Key Lab Chem Biol & Tradit Chinese Med Res, Minist Educ, Changsha, Hunan, Peoples R China
[2] China Tobacco Yunnan Ind Co Ltd, Key Lab Tobacco Chem Yunnan Prov, Res & Dev Ctr, Kunming, Yunnan, Peoples R China
[3] Hengyang Normal Univ, Coll Econ & Management, Hengyang, Peoples R China
基金
中国国家自然科学基金;
关键词
Aqueous two-phase polymerization; Capillary liquid chromatography; Gas chromatography; Hydrophilic chromatography; Porous layer open tubular; LIQUID-CHROMATOGRAPHY; CARRIER SOLVENTS; HYBRID MONOLITH; SEPARATION; MS; CHLOROPHENOLS; PERFORMANCE; PEPTIDES; PROTEINS;
D O I
10.1002/elps.201800410
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The easy shrinkage and swelling of polymer monolithic column when exposed to mobile phase with different polarity is a problem that cannot be ignored. To overcome this drawback, a convenient aqueous two-phase polymerization approach was used to prepare poly (polyethylene glycol diacrylate, PEGDA) monolithic porous layer open tubular (mono-PLOT) columns (150 mu m). The poly(PEGDA) mono-PLOT column with homogeneous polymer porous layer was synthesized successfully. A maximum plate number of 41,500 plates per meter for allyl thiourea was obtained under a velocity of 1.8 mm/s. Several kinds of polar molecule were separated on the proposed mono-PLOT column and a typical hydrophilic interaction retention mechanism was observed. High speed separation of benzoic acids was also carried out, baseline separation of five benzoic acids was successfully achieved within 5 min with a 70 cm mono-PLOT column at 50 degrees C. Furthermore, the resulting PLOT column was also successfully applied to separate standard analytes of three DNA oxidative damage products and RNA-modified nucleosides and four chlorophenols. At last, the column could separate alcohols, alkanes, and aromatic isomers via GC. It had more than 20,000 plates per meter for butanol - higher than commercial coatings open tubular columns.
引用
收藏
页码:521 / 529
页数:9
相关论文
共 9 条
  • [1] Monolithic porous layer open tubular (monoPLOT) capillary columns for gas chromatography
    Nesterenko, Ekaterina P.
    Burke, Maurice
    de Bosset, Christophe
    Pessutto, Paulo
    Malafosse, Claire
    Collins, David A.
    RSC ADVANCES, 2015, 5 (11) : 7890 - 7896
  • [2] PREPARATION AND PROPERTIES OF POROUS LAYER OPEN TUBULAR (PLOT) COLUMNS FOR GAS CHROMATOGRAPHY
    GRANT, DW
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1968, 236 (APR): : 118 - &
  • [3] ADSORPTION CHROMATOGRAPHY ON PLOT (POROUS-LAYER OPEN-TUBULAR) COLUMNS - A NEW LOOK AT THE FUTURE OF CAPILLARY GC
    DEZEEUW, J
    DENIJS, RCM
    HENRICH, LT
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1987, 25 (02) : 71 - 83
  • [4] Infrared photo-initiated fabrication of monolithic porous layer open tubular (monoPLOT) capillary columns for chromatographic applications
    Collins, David A.
    Nesterenko, Ekaterina P.
    Paull, Brett
    RSC ADVANCES, 2014, 4 (53): : 28165 - 28170
  • [5] Controlled Ultraviolet (UV) Photoinitiated Fabrication of Monolithic Porous Layer Open Tubular (monoPLOT) Capillary Columns for Chromatographic Applications
    Collins, David A.
    Nesterenko, Ekaterina P.
    Brabazon, Dermot
    Paull, Brett
    ANALYTICAL CHEMISTRY, 2012, 84 (07) : 3465 - 3472
  • [6] Practical aspects of preparation, optimization, and evaluation of poly (styrene-divinylbenzene)porous-layer open tubular (PLOT) columns for capillary liquid chromatography
    da Silva Burato, Juliana Soares
    Basolli Borsatto, Joao Victor
    Lancas, Fernando Mauro
    TALANTA, 2023, 253
  • [7] The fabrication of carboxylic acid-functionalized porous layer open tube column and its application in hydrophilic interaction chromatography for small polar molecules
    Tang, Shiyun
    Duan, Yuanxing
    Chang, Feng
    Jiang, Wei
    Zhang, Fengmei
    Liu, Zhihua
    Yang, Yuting
    Liu, Chunbo
    Chen, Yingzhuang
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2020, 43 (19-20) : 913 - 924
  • [8] Hydrophilic interaction 10 μm ID porous layer open tubular columns for ultratrace glycan analysis by liquid chromatography-mass spectrometry
    Luo, Quanzhou
    Rejtar, Tomas
    Wu, Shiaw-Lin
    Karger, Barry L.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (08) : 1223 - 1231
  • [9] The fabrication of monolithic capillary column based on poly (bisphenol A epoxy vinyl ester resin-co-ethylene glycol dimethacrylate) and its applications for the separation of small molecules in high performance liquid chromatography
    Niu, Wenjing
    Wang, Lijuan
    Bai, Ligai
    Yang, Gengliang
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1297 : 131 - 137