This research presents immunohistochemical strategies for assessing the interactions at the immediate interface between micro-scale implanted devices and the surrounding brain tissue during inflammatory astrogliotic reactions. This includes preparation, microscopy and analysis techniques for obtaining images of the intimate contact between neural cells and the surface of implantable micro-electromechanical systems (MEMS) devices. The ability to visualize the intact interface between an implant and the surrounding tissue allows researchers to examine tissue that is unchanged from its native implanted state. Conversely, current popular techniques involve removing the implant. This tends to cause damage to the tissue immediately surrounding the implant and can hinder one's ability to differentiate inflammatory responses to the implant versus physical damage occurring from removal of the implant from the tissue. Due to advances in microscopy and staining techniques, it is now possible to visualize the intact tissue-implant interface. This paper presents the development of imaging techniques for visualizing the intact interface between neural tissue and implanted devices. This is particularly important for understanding both the acute and chronic neuroinflammatory responses to devices intended for long-term use in a prosthetic system. Non-functional, unbonded devices were imaged in vitro and in vivo at different times post-implantation via a range of techniques. Using these techniques, detailed interactions could be seen between delicate cellular processes and the electrode surface, which would have been destroyed using conventional histology processes.
引用
收藏
页码:97 / 102
页数:6
相关论文
共 50 条
  • [1] Strategies for minimizing glial response to chronically-implanted microelectrode arrays for neural interface
    Lee Y.
    Jun S.B.
    Jun, S. B. (juns@ewha.ac.kr), 1600, Springer Verlag (04): : 120 - 128
  • [2] FABRICATION OF BIODEGRADABLE SOFT TISSUE-MIMICKED MICROELECTRODE ARRAYS FOR IMPLANTED NEURAL INTERFACING
    Huang, Wei-Chen
    Lei, Wan-Lou
    Peng, Chih-Wei
    2023 IEEE 36TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, MEMS, 2023, : 392 - 395
  • [3] Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes
    Huntington Med. Research Institute, Neurological Research Laboratory, Pasadena, CA 91105, United States
    IEEE Trans. Rehabil. Eng., 3 (315-326):
  • [4] Fabrication of microelectrode arrays for neural measurements from retinal tissue
    Cunningham, W
    Mathieson, K
    McEwan, FA
    Blue, A
    McGeachy, R
    McLeod, JA
    Morris-Ellis, C
    O'Shea, V
    Smith, KM
    Litke, A
    Rahman, M
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (18) : 2804 - 2809
  • [5] Extraction force and cortical tissue reaction of silicon microelectrode arrays implanted in the rat brain
    McConnell, George C.
    Schneider, Thomas M.
    Owens, D. Jason
    Bellamkonda, Ravi V.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (06) : 1097 - 1107
  • [6] Host tissue response to floating microelectrode arrays chronically implanted in the feline spinal nerve
    Kolarcik, Christi L.
    Castro, Carlos A.
    Lesniak, Andrew
    Demetris, Anthony J.
    Fisher, Lee E.
    Gaunt, Robert A.
    Weber, Douglas J.
    Cui, X. Tracy
    JOURNAL OF NEURAL ENGINEERING, 2020, 17 (04)
  • [7] Neural interface dynamics following insertion of hydrous iridium oxide microelectrode arrays
    Johnson, Matthew D.
    Langhals, Nicholas B.
    Kipke, Daryl R.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 5798 - +
  • [8] PEDOT/MWCNT composite film coated microelectrode arrays for neural interface improvement
    Chen, Sanyuan
    Pei, Weihua
    Gui, Qiang
    Tang, Rongyu
    Chen, Yuanfang
    Zhao, Shanshan
    Wang, Huan
    Chen, Hongda
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 193 : 141 - 148
  • [9] Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex
    Vetter, RJ
    Williams, JC
    Hetke, JF
    Nunamaker, EA
    Kipke, DR
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (06) : 896 - 904
  • [10] The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull
    Biran, Roy
    Martin, Dave C.
    Tresco, Patrick A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 82A (01) : 169 - 178