Embedded fiber optic sensor arrays for structural health monitoring of Filament wound composite pressure vessels

被引:26
|
作者
Foedinger, RC [1 ]
Rea, DL [1 ]
Sirkis, JS [1 ]
Baldwin, CS [1 ]
Troll, JR [1 ]
Grande, R [1 ]
Davis, CS [1 ]
VanDiver, TL [1 ]
机构
[1] Technol Dev Associates Inc, Wayne, PA 19087 USA
关键词
Bragg grating; filament winding; composite pressure vessels; health monitoring; fiberoptic sensors;
D O I
10.1117/12.349740
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Optical Fiber Bragg Grating (FBG) strain and temperature sensors were embedded into four carbon/epoxy, filament-wound 5.75 " diameter Standard Testing and Evaluation Bottles (STEBs). These sensors were used to monitor temperature and strain during cure and pressurization of the pressure vessels. Preliminary to this work, micrographs were made of embedded fiber, showing good incorporation of the fiber into the material and no degradation of the optical fiber's acrylate coating. A survey was also made of different ingress/egress techniques to protecting the fiber as in enters the bottle and preventing attenuation and power fluctuation, with Tefzel tubing proving to be the most effective method. The FBGs were embedded parallel to the reinforcing fibers, in the: hoop and helical directions, and also in the axial direction. The sensors showed close agreement with surface-mounted Resistance Strain Gages (RSGs), as well as finite element modeling. Sensors in the hoop direction embedded at mid-cylinder showed the closest agreement (-12%), while agreement for hoop-direction sensors embedded near the ends of the bottle (11%) was not as close. The agreement was also better for helically directed sensors embedded at mid-cylinder (-1.6%?) than for those embedded near the ends (-24%). Some preliminary impact testing was conducted that indicated FBG sensors would be appropriate for sensing impact damage.
引用
收藏
页码:289 / 301
页数:13
相关论文
共 50 条
  • [1] Structural health monitoring of filament wound composite pressure vessels with embedded optical fiber sensors
    Foedinger, R
    Rea, D
    Sirkis, J
    Wagreich, R
    Troll, J
    Grande, R
    Davis, C
    Vandiver, TL
    [J]. 43RD INTERNATIONAL SAMPE SYMPOSIUM AND EXHIBITION ON MATERIALS AND PROCESS AFFORDABILITY - KEYS TO THE FUTURE, VOL 43, 1998, : 444 - 457
  • [2] Fiber optic sensor system for filament-wound pressure vessels
    Knapp, RH
    Robertson, IN
    [J]. PROCEEDINGS OF THE 10TH (2000) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL IV, 2000, : 77 - 82
  • [3] Structural health monitoring and impact damage detection for filament wound composite pressure vessels
    Foedinger, R
    Rea, D
    Sirkis, J
    Troll, J
    Grande, R
    Vandiver, TL
    [J]. STRUCTURAL HEALTH MONTORING 2000, 1999, : 159 - 169
  • [4] Distributed fiber optic sensors for structural health monitoring of composite pressure vessels
    Karapanagiotis, Christos
    Schukar, Marcus
    Krebber, Katerina
    [J]. TM-TECHNISCHES MESSEN, 2024, 91 (3-4) : 168 - 179
  • [5] Structural integrity of filament wound composite structures with embedded fiber optic sensors
    Foedinger, R
    Sirkis, J
    Chang, CC
    Vandiver, TL
    [J]. EVOLVING TECHNOLOGIES FOR THE COMPETITIVE EDGE, BOOKS 1 AND 2, 1997, 42 : 368 - 379
  • [6] Evaluation of fiber material properties in filament-wound composite pressure vessels
    Hwang, Tae-Kyung
    Park, Jae-Beom
    Kim, Hyoung-Geun
    [J]. COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2012, 43 (09) : 1467 - 1475
  • [7] Structural Health Monitoring of Hydrogen Pressure Vessels using Distributed Fiber Optic Sensing
    Karapanagiotis, Christos
    Schukar, Marcus
    Breithaupt, Mathias
    Duffner, Eric
    Ulbricht, Alexander
    Prager, Jens
    Krebber, Katerina
    [J]. e-Journal of Nondestructive Testing, 2024, 29 (07):
  • [8] Characterization of embedded fiber optic sensors in advanced composite materials for structural health monitoring
    Richards, WL
    Lee, DG
    Piazza, A
    Stewart, A
    Carman, GP
    [J]. SMART STRUCTURES AND MATERIALS 2004: SMART STRUCTURES AND INTEGRATED SYSTEMS, 2004, 5390 : 505 - 512
  • [9] Influence of mosaic patterns on the structural integrity of filament wound composite pressure vessels
    Mian, Haris Hameed
    Rahman, Hammad
    [J]. INTERNATIONAL JOURNAL OF STRUCTURAL INTEGRITY, 2011, 2 (03) : 345 - 356
  • [10] EFFECT OF EMBEDDED ELECTRIC SENSOR ON THE STRUCTURAL STRENGTH OF FILAMENT WOUND HYBRID COMPOSITE
    Sianaki, Abolfazl Ameri
    Evans, Brian
    Rasouli, Vamegh
    Roufail, Reem
    Stewart, Gordon
    [J]. 33RD INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2014, VOL 5, 2014,