Photon-counting phase-modulation fluorometer

被引:18
|
作者
Iwata, T [1 ]
Hori, A [1 ]
Kamada, T [1 ]
机构
[1] Univ Tokushima, Fac Engn, Dept Mech Engn, Tokushima 7708506, Japan
关键词
phase-modulation fluorometer; photon counting; fluorescence; ultraviolet light-emitting diode; spectroscopic instruments; benzo[a]pyrene;
D O I
10.1007/s10043-001-0326-8
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a phase-modulation fluorometer that is applicable to a very weak fluorescence intensity level. In order to counter the single-photon event situation, we have introduced a combination of a time-to-amplitude converter and a pulse height analyzer (PHA) to the fluorometer, the combination of which is usually used in the single-photon correlation method to measure fluorescence decay waveforms with pulsed excitation. In the proposed fluorometer, a sinusoidal response waveform that is shifted in phase over the reference one is obtained statistically as a histogram in the PHA memory, and then the fluorescence lifetime can be calculated by the same procedure as the conventional analog phase-modulation method. The excitation light source used was a current-modulated ultraviolet light-emitting diode, Whose center wavelength was 370 nm and whose spectral bandwidth was 10 nm. Fluorescence lifetimes of 17.5 ns and 5.7 ns obtained for 10 ppb quinine sulfate in 0.1 N H2SO4 and for 10 ppb rhodamine 6G in ethanol, respectively, agreed well with those reported in the literature. In passing, we report that the fluorescence lifetime of benzo[a]pyrene in dichloromethane is 14.6 ns, which is known as one of the carcinogenic, environmental-pollution materials.
引用
收藏
页码:326 / 330
页数:5
相关论文
共 50 条
  • [1] Photon-Counting Phase-Modulation Fluorometer
    Tetsuo Iwata
    Akio Hori
    Takeshi Kamada
    Optical Review, 2001, 8 : 326 - 330
  • [2] Photon-counting phase-modulation fluorometer for lifetime measurements
    Iwata, T
    Hori, A
    Kamada, T
    OPTICAL ENGINEERING FOR SENSING AND NANOTECHNOLOGY (ICOSN 2001), 2001, 4416 : 462 - 465
  • [3] Photon-counting 1.0 GHz-phase-modulation fluorometer
    Mizuno, T.
    Nakao, S.
    Mizutani, Y.
    Iwata, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (04):
  • [4] FPGA-based photon-counting phase-modulation fluorometer and a brief comparison with that operated in a pulsed-excitation mode
    Tetsuo Iwata
    Takanori Taga
    Takahiko Mizuno
    Optical Review, 2018, 25 : 94 - 101
  • [5] FPGA-based photon-counting phase-modulation fluorometer and a brief comparison with that operated in a pulsed-excitation mode
    Iwata, Tetsuo
    Taga, Takanori
    Mizuno, Takahiko
    OPTICAL REVIEW, 2018, 25 (01) : 94 - 101
  • [6] Fourier-transform phase-modulation fluorometer
    Iwata, T
    Kamada, T
    Araki, T
    OPTICS FOR THE QUALITY OF LIFE, PTS 1 AND 2, 2003, 4829 : 920 - 921
  • [7] DESIGN AND EVALUATION OF A FILTER FLUOROMETER THAT INCORPORATES A PHOTON-COUNTING DETECTOR
    CURRY, RE
    PARDUE, HL
    MIELING, GE
    SANTINI, RE
    CLINICAL CHEMISTRY, 1973, 19 (11) : 1259 - 1264
  • [8] Proposal for Fourier-Transform Phase-Modulation Fluorometer
    Tetsuo Iwata
    Optical Review, 2003, 10 : 31 - 37
  • [9] Construction of a Fourier-transform phase-modulation fluorometer
    Iwata, T
    Shibata, H
    Araki, T
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (11) : 2351 - 2356
  • [10] Proposal for Fourier-transform phase-modulation fluorometer
    Iwata, T
    OPTICAL REVIEW, 2003, 10 (01) : 31 - 37