Effect of Thickness on the Space Charge Behavior and DC Breakdown Strength of Cross-Linked Polyethylene Insulation

被引:5
|
作者
Ma, Zhipeng [1 ]
Yang, Lijun [1 ]
Bhutta, Muhammad Shoaib [1 ]
Bian, Haoran [1 ]
Khan, Muhammad Zeeshan [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
来源
IEEE ACCESS | 2020年 / 8卷
关键词
Breakdown; thickness; space charge accumulation; XLPE; FILM THICKNESS; DYNAMICS; ELECTRON;
D O I
10.1109/ACCESS.2020.2990759
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In high voltage direct current (HVDC) cable systems, study of electric field distortion created by space charge accumulation is very important for examining insulation performance. Therefore, in this paper the infiuence of space charge on short-time breakdown characteristics of cross-linked polyethylene (XLPE) are studied. Trap energy distribution is an important factor affecting space charge behavior in dielectrics. Dielectrics with various thicknesses exhibit different space charge phenomena due to various trap distribution characteristics, which regulate the injection, migration and accumulation processes of charges. Consequently, trap characteristics can affect many parameters, such as charge accumulation depth and injection barrier. XLPE with thickness less than 100 fim show lower density of deep traps which can accumulate homogeneous bulk charges as compared to thick XLPE with thickness greater than 100 fim. This phenomenon determines the internal field strength distortion rate which is 20% larger for thin XLPE and it is much higher than that for thick XLPE. The external factor which is considered for analysis is applied field strength and it shows a linear proportional affect on the electric field distortion. A quantitative relationship model between applied field strength and distortion field strength of XLPE with different thicknesses was established. Linear extrapolation was used to obtain the trend of applied, distortion, and actual field strengths at different XLPE thicknesses when breakdown occurred. When the thickness of XLPE is less than 100 fim, distortion field strengths is higher than 50 kV/mm and increases with decreasing thickness, resulting in a significant effect on the breakdown phenomenon and breakdown strength increases with increasing thickness. And when the thickness of XLPE is greater than 100 fim, the distortion field strengths is less than 50 kV/mm which also confirms the volume effect on breakdown phenomenon and breakdown strength decreases with increasing thickness.
引用
收藏
页码:85552 / 85566
页数:15
相关论文
共 50 条
  • [1] Space charge behavior of chemically cross-linked and radiation cross-linked polyethylene
    Martinotto, L
    Peruzzotti, F
    Palmieri, F
    Montanari, GC
    Rai, S
    [J]. 2000 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS. I & II, 2000, : 109 - 112
  • [2] Positive Space Charge behavior in Cross-Linked Polyethylene
    Rogti, F.
    [J]. 2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 101 - 104
  • [3] Space charge behavior at physical interfaces in cross-linked polyethylene under DC field
    Rogti, F.
    Mekhaldi, A.
    Laurent, C.
    [J]. 2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 9 - +
  • [4] Space Charge Behavior at Physical Interfaces in Cross-linked Polyethylene under DC Field
    Rogti, F.
    Mekhaldi, A.
    Laurent, C.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (05) : 1478 - 1485
  • [5] Effect of Temperature on Space Charge and Periodic Grounded DC tree in Cross-linked Polyethylene
    Wang, Yani
    Li, Guangdao
    Wu, Jiandong
    Yin, Yi
    [J]. 2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 48 - 51
  • [6] Investigation of the Thickness Effect on DC Breakdown Strength for HVDC Flexible Cable Insulation Associated with Space Charge
    Su, Pengfei
    Yin, Yi
    Zheng, Xinlong
    Xuan, Yaowei
    Wu, Jiandong
    [J]. 2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 242 - 245
  • [7] Temperature effect of space charge distribution in cross-linked polyethylene
    Lan, Li
    Wu, Jiandong
    Yin, Yi
    Nilsson, Ulf H.
    Lennartsson, Hakan
    Zhou, Alex
    [J]. PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 1085 - 1088
  • [8] Effect of Temperature on Space Charge Detrapping and Periodic Grounded DC Tree in Cross-linked Polyethylene
    Wang, Yani
    Li, Guangdao
    Wu, Jiandong
    Yin, Yi
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (06) : 3704 - 3711
  • [9] Investigation on dielectric breakdown behavior of thermally aged cross-linked polyethylene cable insulation
    Kim, Chonung
    Jiang, Pingkai
    Liu, Fei
    Hyon, Songchol
    Ri, Myong-guang
    Yu, Yongmyong
    Ho, Myongsong
    [J]. POLYMER TESTING, 2019, 80
  • [10] Influence of Thermal Aging on Space Charge Characteristics and Electrical Conduction Behavior of Cross-Linked Polyethylene Cable Insulation
    Yang, Jie
    Li, Ruizhe
    Hu, Leiyu
    Wang, Weiwang
    [J]. POLYMERS, 2024, 16 (11)