Automatic vs hand-controlled walking of paraplegics

被引:40
|
作者
Popovic, D
Radulovic, M
Schwirtlich, L
Jaukovic, N
机构
[1] Aalborg Univ, Ctr Sensory Motor Interact, DK-9220 Aalborg, Denmark
[2] Univ Montenegro, Fac Elect Engn, Montenegro, Serbia
[3] Inst Rehabil Dr Miroslav Zotovic, Belgrade, Serbia
关键词
automatic control; walking; paraplegia; functional electrical stimulation (FES); energy cost; physiological cost index;
D O I
10.1016/S1350-4533(02)00188-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A rule-based control and its application in functional electrical stimulation (FES) assisted walking of subjects with paraplegia are described in this paper. The design of rules for control comprises the following two steps: (1) determination of muscle activation patterns by using a fully customized spatial (3D) model of paraplegic walking, and (2) learning of rules, that is, correlation between the muscle activation patterns and kinematics of walking by means of an artificial neural network. The adopted FES system activated eight muscle groups with surface electrodes. The only joints allowing movement in the coronal plane were the hips, and externally controlled joints in sagittal plane were ankles, knees and hips. The simulation minimized the tracking error of the joint angles and the total activation of all eight muscles being stimulated. A radial-basis function artificial neural network was applied for learning of rules. Three automatically controlled modes (slow, near-normal, and near-ballistic) and hand-controlled walking were evaluated in six subjects with a complete spinal cord lesion (T8-T10). The performance of walking was assessed by the following: (1) energy consumption based on oxygen uptake, (2) physiological cost index, (3) maximum speed of walking, and (4) a questionnaire. The results showed that all modes of walking are achievable and that automatic control leads to more efficient and faster walking. The speed of walking achieved by automatic control was almost three times bigger compared with the speed of hand-controlled walking. The energy cost and rate decreased significantly when automatic control was applied; yet, they were still much bigger than the values measured in able-bodied subjects. The objective outcome measures suggest that the near-ballistic walking was the most effective, yet a questionnaire shows that most subjects preferred slow walking. The most likely reason for the preference of lower efficiency walking over the faster end energy efficient near-ballistic walking was that paraplegic patients had difficulties in synchronizing the voluntary movement of the trunk and arms to the artificially controlled movements of legs. (C) 2002 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:63 / 73
页数:11
相关论文
共 50 条
  • [1] Design of a hand-controlled ride-on truck
    Zawaski, S
    Wanat, A
    Snyder, M
    Mickal, M
    [J]. IEEE REGION 5 2003 ANNUAL TECHNICAL CONFERENCE, CONFERENCE RECORD, 2003, : 17 - 19
  • [2] Robot Hand-Controlled by Gyroscope Sensor Using Arduino
    Ghali, Fatima
    Ouda, Atheer Y.
    [J]. FORTHCOMING NETWORKS AND SUSTAINABILITY IN THE AIOT ERA, VOL 1, FONES-AIOT 2024, 2024, 1035 : 275 - 285
  • [3] Computerized chironomy: evaluation of hand-controlled Intonation reiteration
    d'Alessandro, Christophe
    Rilliard, Albert
    Le Beux, Sylvain
    [J]. INTERSPEECH 2007: 8TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION, VOLS 1-4, 2007, : 1721 - 1724
  • [4] PCM FORCE MEASUREMENT TECHNIQUES WITH HAND-CONTROLLED TOOLS
    BORSA, B
    [J]. F&M-FEINWERKTECHNIK & MESSTECHNIK, 1984, 92 (02): : 81 - 82
  • [5] A hand-controlled, 3D ultrasound guide and measurement system
    Fenn, RC
    Fowlkes, JB
    Moskalik, AP
    Zhang, Y
    Roubidoux, MA
    Carson, PL
    [J]. ACOUSTICAL IMAGING, VOL 23, 1997, 23 : 237 - 242
  • [6] Application of a hand-controlled abrasive water-jet system for dismantling of metal components
    Louis, H
    Oppermann, M
    Pude, F
    [J]. 15TH INTERNATIONAL CONFERENCE ON JETTING TECHNOLOGY, 2000, (41): : 69 - 76
  • [7] WALKING-AID FOR PARAPLEGICS
    ALLISON, RS
    [J]. BRITISH MEDICAL JOURNAL, 1957, 2 (AUG10): : 350 - 351
  • [8] WALKING APPLIANCES FOR PARAPLEGICS AND TETRAPLEGICS
    HENSHAW, JT
    [J]. PARAPLEGIA, 1979, 17 (02): : 163 - 168
  • [9] AN ECONOMICAL SAFE HAND-CONTROLLED DEVICE FOR RAISING SMALL QUANTITIES OF LIQUIDS BY COMPRESSED AIR
    SEBBORN, WS
    [J]. JOURNAL OF SCIENTIFIC INSTRUMENTS, 1958, 35 (04): : 149 - 149
  • [10] Patterning a hydrogen-bonded molecular monolayer with a hand-controlled scanning probe microscope
    Green, Matthew F. B.
    Esat, Taner
    Wagner, Christian
    Leinen, Philipp
    Groetsch, Alexander
    Tautz, F. Stefan
    Temirov, Ruslan
    [J]. BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2014, 5 : 1926 - 1932