An electronic portal imaging device for transit dosimetry

被引:25
|
作者
SymondsTayler, JRN [1 ]
Partridge, M [1 ]
Evans, PM [1 ]
机构
[1] ROYAL MARSDEN NHS TRUST,SUTTON SM2 5PT,SURREY,ENGLAND
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1997年 / 42卷 / 11期
关键词
D O I
10.1088/0031-9155/42/11/019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An electronic portal imaging device has been designed and constructed. It consists of an array of 128 CsI scintillation crystals coupled to photodiodes which is scanned across the field in 4 seconds. The linac is operated at a dose rate of 400 cGy min(-1) and the dose delivered for image acquisition is approximate to 27 cGy. The data acquisition controller is a stand-alone STE computer located within the scan arm. Sample images are presented showing contrast and spatial resolution of the system together with a humanoid phantom image and a clinical image of a breast cancer patient. The phantom images show the detector has a contrast resolution of 0.3% (at 15 mm diameter) and a spatial resolution of 2.5-3.2 mm. Images of uniform Perspex blocks have also been calibrated for thickness, indicating the system can measure radiological thickness tp an accuracy of 2-3 mm of water. These results indicate the detector may be used for transit dosimetry applications including compensator design.
引用
收藏
页码:2273 / 2283
页数:11
相关论文
共 50 条
  • [1] Evaluation of an electronic portal imaging device for transit dosimetry
    He, XD
    Van Esch, A
    Reymen, R
    Huyskens, D
    [J]. ACTA ONCOLOGICA, 1999, 38 (05) : 591 - 596
  • [2] An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry
    Grein, EE
    Lee, R
    Luchka, K
    [J]. MEDICAL PHYSICS, 2002, 29 (10) : 2262 - 2268
  • [3] Transit Dosimetry for Verification of Dose Delivery Using Electronic Portal Imaging Device (EPID)
    Baek, T.
    Chung, E.
    Lee, S.
    Yoon, M.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 301 - 301
  • [4] Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients
    Pasma, KL
    Kroonwijk, M
    Quint, S
    Visser, AG
    Heijmen, BJM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05): : 1297 - 1303
  • [5] Dosimetry with a fluoroscopic electronic portal imaging device
    Pasma, KL
    [J]. MEDICAL PHYSICS, 2000, 27 (02) : 423 - 423
  • [6] Transit Dosimetry of SBRT with Electronic Portal Dosimetry Device in Patient with Spinal Implant
    Yedekci, Y.
    Elmali, A.
    Demirkiran, G.
    Ozyigit, G.
    Yazici, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1486 - S1486
  • [7] Electronic portal imaging device-based dosimetry
    Pinol, R. De Blas
    Farre, I. Modolell
    Olmos, C. Picon
    Kolster, I. Sancho
    Vaque, J. Puxeu
    Arroyo, M. Lizuain
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S187 - S187
  • [8] The use of an electronic portal imaging device for exit dosimetry
    Conte, L
    Stucchi, P
    Mordacchini, C
    Bianchi, C
    Monciardini, M
    Novario, R
    Cassani, E
    Mantovani, R
    Antognoni, P
    Tordiglione, M
    [J]. PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 279 - 281
  • [9] Development of an Electronic Portal Imaging Device Dosimetry Method
    Zhang, Jun
    Fan, Ziting
    Zhang, Xile
    Yang, Ruijie
    Wen, Junhai
    [J]. DIAGNOSTICS, 2021, 11 (09)
  • [10] A Monte Carlo calculation model of electronic portal imaging device for transit dosimetry through heterogeneous media
    Yoon, Jihyung
    Jung, Jae Won
    Kim, Jong Oh
    Yeo, Inhwan
    [J]. MEDICAL PHYSICS, 2016, 43 (05) : 2242 - 2250