Portable Forced Oscillation Device for Point-of-care Pulmonary Function Testing

被引:0
|
作者
Cao, Jian [1 ]
Sabharwal, Ashutosh [1 ]
机构
[1] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77025 USA
关键词
HOME;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The forced oscillation technique (FOT) provides a simple and accurate approach for pulmonary function testing. However, most current devices are large and high cost, hence the test remains sparingly used. To address this problem, we verified the feasibility of a smart and portable forced oscillation device based on a small subwoofer and ultrasonic sensor that is targeted at point-of-care pulmonary function testing. In this paper, we first develop and optimize the signal processing algorithm for impedance estimation. Then we characterize the signal quality of programmable oscillatory waveforms with varying frequency, amplitude and duration. Finally, we evaluate the performance of the device against both mechanical models and human subjects. The results show that the coherence function is above 0.9 for all frequencies and the measurement error is less than 10%. The device yields good repeatability and satisfies the clinical diagnostic requirements.
引用
收藏
页码:2282 / 2286
页数:5
相关论文
共 50 条
  • [1] Portable point-of-care device for haemoglobin testing
    Mohan, Alladi
    [J]. NATIONAL MEDICAL JOURNAL OF INDIA, 2014, 27 (03): : 186 - 187
  • [2] Development of Portable Device for Point-of-Care Testing of Tumor Marker
    Fan Yan
    Wang Yang
    Liu Jun-Tao
    Luo Jin-Ping
    Xu Hui-Ren
    Xu Sheng-Wei
    Cai Xin-Xia
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (07) : 1148 - 1153
  • [3] A portable point-of-care testing device for forward blood typing with hemophilia diagnosis
    Chang, Yaw-Jen
    Yeh, Shang-Fen
    Chen, Pin-Jyun
    [J]. BIOMEDICAL MICRODEVICES, 2023, 25 (04)
  • [4] A portable point-of-care testing device for forward blood typing with hemophilia diagnosis
    Yaw-Jen Chang
    Shang-Fen Yeh
    Pin-Jyun Chen
    [J]. Biomedical Microdevices, 2023, 25
  • [5] Monitoring pulmonary function in asthma and COPD: Point-of-care testing
    Tovar, JM
    Gums, JG
    [J]. ANNALS OF PHARMACOTHERAPY, 2004, 38 (01) : 126 - 133
  • [6] The portable laboratory and emergency department point-of-care testing
    van Heyningen, C
    Watson, ID
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1999, 36 : 531 - 531
  • [7] Point-of-Care Platelet Function Testing
    Harle, Christopher C.
    [J]. SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 11 (04) : 247 - 251
  • [8] A Portable Electromagnetic Induction Heating Device for Point-of-Care Diagnostics
    Ahn, Myun-Hwan
    Baek, Seung-Ki
    Min, JunHong
    Park, Jung-Hwan
    [J]. BIOCHIP JOURNAL, 2016, 10 (03) : 208 - 214
  • [9] Combined Impedance and Dielectrophoresis Portable Device for Point-of-Care Analysis
    del Moral Zamora, B.
    Colomer-Farrarons, J.
    Mir-Llorente, M.
    Homs-Corbera, A.
    Miribel-Catala, P.
    Samitier-Marti, J.
    [J]. BIOELECTRONICS, BIOMEDICAL, AND BIOINSPIRED SYSTEMS V AND NANOTECHNOLOGY V, 2011, 8068
  • [10] Portable fluorescence reader for Point-of-Care Molecular Diagnostic device
    Srinivasan, Rajesh
    Rawat, Kapil Singh
    Aswathappa, Roopa
    Christo, Eugene V. R.
    Gorthi, Sai Siva
    [J]. 2019 IEEE 16TH INDIA COUNCIL INTERNATIONAL CONFERENCE (IEEE INDICON 2019), 2019,