A biomechanical and radiographic analysis of standard and intracortical suture anchors for arthroscopic rotator cuff repair

被引:29
|
作者
Mahar, A
Allred, DW
Wedemeyer, M
Abbi, G
Pedowitz, R
机构
[1] Childrens Hosp, Orthoped Biomech Res Ctr, San Diego, CA 92123 USA
[2] Univ Calif San Diego, Dept Orthopaed Surg, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Sch Med, San Diego, CA 92103 USA
关键词
rotator cuff; repair; suture anchors; biomechanics; implant migration;
D O I
10.1016/j.arthro.2005.08.042
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the fixation strength and radiographic motion of an anchor designed for intracortical (IC) fixation (FT Anchor, Arthrex, Naples, FL) with that of standard anchors used for rotator cuff repair. Type of Study: In vitro human cadaveric biomechanical study. Methods: Four types of metallic suture anchors (8 per group) were randomly inserted into human cadaveric humeri using an IC anchor and 3 types of standard anchors. Anchors were inserted 45 degrees to the humeral head surface and 90 degrees to the rotator cuff line of action. Anchors were tested under physiologic loads for 500 cycles followed by a failure test. The number of cycles, failure mode, and failure load were recorded. Fluoroscopy was used to measure rotation and displacement of the anchor within the humeral head during testing. Data were analyzed using a 1-way analysis of variance with a correction for multiple comparisons. Results: There were no significant differences in anchor displacement or rotation measured by fluoroscopy after cyclic loading. Total construct displacement across anchors ranged from 4.9 to 7.8 mm, well beyond the 3-mm failure criterion reported in the literature. The IC anchor had a statistically significant greater failure load than the other devices. There was no significant difference in failure load between the other 3 anchors. The anchor had the greatest number of cycles to 3 mm of failure. This was not significantly different than the TwinFix anchor (Smith & Nephew, Andover, MA), but both values were significantly greater than both the Super Revo (Linvatec, Largo, FL) and Fastin RC (DePuy Mitek, Raynham, MA) anchors. Conclusions: Anchor motion accounted for about one third of total displacement of the suture/anchor construct. IC fixation anchors performed well compared with standard anchors in human cadaveric bone. Clinical Relevance: Fluoroscopic imaging showed both rotation and displacement of the anchor within the humeral head which may contribute to early gap formation after rotator cuff repairs.
引用
收藏
页码:130 / 135
页数:6
相关论文
共 50 条
  • [1] Suture anchors in arthroscopic rotator cuff repair
    George, MS
    Kuhn, JE
    [J]. OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2004, 12 (04) : 210 - 214
  • [2] The Evolution of Suture Anchors in Arthroscopic Rotator Cuff Repair
    Denard, Patrick J.
    Burkhart, Stephen S.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (09): : 1589 - 1595
  • [3] A biomechanical evaluation of suture anchors in repair of the rotator cuff
    Rossouw, DJ
    McElroy, BJ
    Amis, AA
    Emery, RJH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03): : 458 - 461
  • [4] A biomechanical analysis of a novel arthroscopic suture method compared to standard suture knots and materials for rotator cuff repair
    Mahar, Andrew
    Odell, Tim
    Thomas, Walter
    Pedowitz, Robert
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (11): : 1162 - 1166
  • [5] Arthroscopic revision surgery after arthroscopic rotator cuff repair with suture anchors
    Halbgewachs, J.
    Buess, E.
    [J]. ARTHROSKOPIE, 2008, 21 (03) : 138 - 144
  • [6] Advantages of Arthroscopic Transosseous Suture Repair of the Rotator Cuff without the Use of Anchors
    Kuroda, Shigehito
    Ishige, Noriyuki
    Mikasa, Motohiko
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (11) : 3514 - 3522
  • [7] Arthroscopic biceps tenodesis incorporated into rotator cuff repair using suture anchors
    George, Michael S.
    [J]. ORTHOPEDICS, 2008, 31 (06) : 552 - 555
  • [8] Rotator Cuff Sparing Arthroscopic SLAP Repair With Knotless All-Suture Anchors
    Dekker, Travis J.
    Lacheta, Lucca
    Goldenberg, Brandon
    Grantham, W. Jeffrey
    Millett, Peter J.
    [J]. ARTHROSCOPY TECHNIQUES, 2019, 8 (09): : E993 - E998
  • [9] Arthroscopic Rotator Cuff Repair With Metal and Biodegradable Suture Anchors: A Prospective Randomized Study
    Milano, Giuseppe
    Grasso, Andrea
    Salvatore, Matteo
    Saccomanno, Maristella F.
    Deriu, Laura
    Fabbriciani, Carlo
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (09): : S112 - S119
  • [10] Arthroscopic rotator cuff repair using triple-loaded anchors, suture shuttles, and suture savers
    Burns, Joseph P.
    Snyder, Stephen J.
    Albritton, Mark
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2007, 15 (07) : 432 - 444