Simultaneous high-performance liquid chromatographic determination of ochratoxin A and citrinin in cheese by time-resolved luminescence using terbium

被引:54
|
作者
Vazquez, BI [1 ]
Fente, C [1 ]
Franco, C [1 ]
Cepeda, A [1 ]
Prognon, P [1 ]
Mahuzier, G [1 ]
机构
[1] UNIV PARIS 11,FAC PHARM,LAB CHIM ANALYT 2,F-92290 CHATENAY MALABRY,FRANCE
关键词
food analysis; luminescence; time-resolved luminescence detection; detectors; LC; ochratoxin A; citrinin; mycotoxins; toxins; terbium;
D O I
10.1016/0021-9673(95)01174-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simultaneous reversed-phase HPLC determination of two major mycotoxins, ochratoxin A and citrinin, in soft cheese is proposed. Both mycotoxins are eluted on a C-18 RP support (25 x 4.6 mm I.D.) using an isocratic eluent consisting of methanol-water (70:30, v/v) containing tetrabutylammonium hydroxide (10(-3) M), acidified to pH 5.5 with HCl, and pumped at a flow-rate of 0.8 ml/min. Prior to detection, a butanolic solution of 5 . 10(-3) M terbium-5 . 10(-4) M trioctylphosphine oxide (TOPO)-2.5 . 10(-2) M triethylamine (TEA) was pumped in a postcolumn mode at a flow-rate of 0.2 ml/min to perform time-resolved luminescence (TRL) detection of the corresponding terbium chelates (lambda(ex) = 331 nm/lambda(em) = 545 nm). The method is linear from 3.5 . 10(-6) to 2 . 10(-5) M for citrinin and from 1 . 10(-5) to 5 . 10(-5) M for ochratoxin A. The repeatability and reproducibility (R.S.D.) are 1.9 and 2.4% for citrinin (c = 3.5 . 10(-6) M; n = 10), and 7.2 and 8.3% for ochratoxin A (c = 1.0 . 10(-5) M; n = 10). The limits of detection, for a signal-to-background ratio of 3, are 2 . 10(-6) and 3 . 10(-6) M for citrinin and ochratoxin A, respectively. With the proposed method, ochratoxin A and citrinin are easily determined in soft cheeses, with a significative increase in selectivity in comparison with direct fluorescence detection.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [1] Time-resolved luminescence as a novel detection mode for the simultaneous high-performance liquid chromatographic determination of gadolinium-DOTA and Gd3+
    Moutiez, E
    Prognon, P
    Bourrinet, P
    Zehaf, S
    Dencausse, A
    Mahuzier, G
    [J]. ANALYST, 1997, 122 (11) : 1347 - 1352
  • [2] SIMULTANEOUS DETERMINATION OF THE MYCOTOXINS CITRININ AND OCHRATOXIN A IN WHEAT AND BARLEY BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LEPOM, P
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 355 (01): : 335 - 339
  • [3] Determination of ibuprofen in pharmaceutical formulations using time-resolved terbium-sensitized luminescence
    Al-Kindy, Salma M. Z.
    Suliman, Fakhr Eldin O.
    [J]. LUMINESCENCE, 2007, 22 (04) : 294 - 301
  • [4] Liquid chromatographic determination using lanthanides as time-resolved luminescence probes for drugs and xenobiotics: Advantages and limitations
    Rieutord, A
    Prognon, P
    Brion, F
    Mahuzier, G
    [J]. ANALYST, 1997, 122 (05) : R59 - R66
  • [5] A high-performance liquid-chromatographic method for the determination of ochratoxin A in human plasma
    Jimenez, AM
    de Cerain, AL
    Gonzalez-Peñas, E
    Bello, J
    [J]. CHROMATOGRAPHIA, 1999, 50 (7-8) : 457 - 460
  • [6] A high-performance liquid-chromatographic method for the determination of ochratoxin a in human plasma
    A. M. Jimenez
    A. López de Cerain
    E. Gonzalez-Peñas
    J. Bello
    [J]. Chromatographia, 1999, 50 : 457 - 460
  • [7] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF OCHRATOXIN-A AND OCHRATOXIN-B IN FOODS
    IBE, A
    NISHIJIMA, M
    YASUDA, K
    SAITO, K
    KAMIMURA, H
    NAGAYAMA, T
    USHIYAMA, H
    NAOI, Y
    NISHIMA, T
    [J]. JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1984, 25 (04): : 334 - 341
  • [8] Quantification of endospores in ancient permafrost using time-resolved terbium luminescence
    Lalla, S. J.
    Kaneshige, K. R.
    Miller, D. R.
    Mackelprang, R.
    Mogul, R.
    [J]. ANALYTICAL BIOCHEMISTRY, 2021, 612
  • [9] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ZEARALENONE AND OCHRATOXIN-A IN CEREALS AND FEED
    LANGSETH, W
    ELLINGSEN, Y
    NYMOEN, U
    OAKLAND, EM
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 478 (01): : 269 - 274
  • [10] Highly sensitive time-resolved fluorometric determination of estrogens by high-performance liquid chromatography using a β-diketonate europium chelate
    Matsumoto, K
    Tsukahara, Y
    Uemura, T
    Tsunoda, K
    Kume, H
    Kawasaki, S
    Tadano, J
    Matsuya, T
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02): : 135 - 142