An instrument for measuring equilibrium-equivalent 222Rn and 220Rn concentrations with etched track detectors

被引:10
|
作者
Zhuo, WH [1 ]
Iida, T [1 ]
机构
[1] Nagoya Univ, Dept Nucl Engn, Grad Sch Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
来源
HEALTH PHYSICS | 1999年 / 77卷 / 05期
关键词
radon progeny; detector; etched-track; instrumentation; monitors; radiation;
D O I
10.1097/00004032-199911000-00013
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To simultaneously measure both Rn-222 and Rn-220 progeny concentrations, a new type of portable integrating monitor with allyl diglycol carbonate (CR-39) plastic detectors was developed, The monitor gives the average equilibrium-equivalent Rn-222 and Rn-220 concentrations (EECRn and EECTn) during sampling intervals. The detection efficiencies of the alpha particles were calculated by Monte Carlo method. The lower limits of detection for EECRn and EECTn are estimated to be 0.57 Bq m(-3) and 0.07 Bq m(-3) for 24 h continuously sampling at a flow rate of 0.8 L min(-1). The measuring results with the new type monitors were confirmed through intercomparison experiments, In a small survey, a rather high Rn-220 progeny concentration with an average of 1.73 Bq m(-3) was observed in traditional Japanese dwellings with soil/mud plastered walls. On the other hand, a very high Th-232 concentration in soil was reported in China. They suggested that there is a possibility of high Rn-220 progeny concentration in both Japan and China.
引用
收藏
页码:584 / 587
页数:4
相关论文
共 50 条
  • [1] Concentrations of 222Rn and 220Rn in indoor air
    Vaupotic, Janja
    Celikovic, Igor
    Smrekar, Natasa
    Zunic, Zora S.
    Kobal, Ivan
    ACTA CHIMICA SLOVENICA, 2008, 55 (01) : 160 - 165
  • [2] Characteristics of 222Rn and 220Rn equilibrium factors in the indoor environments
    Prasad, Mukesh
    Bossew, Peter
    Shetty, Trilochana
    Ramola, R. C.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2023, 268
  • [3] Advances in measurement of indoor 222Rn and 220Rn gas concentrations using solid state nuclear track detectors
    Sahoo, B.K.
    Sapra, B.K.
    Solid State Phenomena, 2015, 238 : 116 - 126
  • [4] INDOOR 222Rn AND 220Rn CONCENTRATIONS AND DOSES IN BANGALORE, INDIA
    Sathish, L. A.
    Nagaraja, K.
    Ramachandran, T. V.
    RADIATION PROTECTION DOSIMETRY, 2012, 151 (02) : 344 - 353
  • [5] 222Rn, 220Rn and their progeny concentrations in offices in Hong Kong
    Yu, KN
    Cheung, T
    Guan, ZJ
    Mui, BWN
    Ng, YT
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2000, 48 (02) : 211 - 221
  • [6] Concentrations of 222Rn, 220Rn and their progeny in residences in Hong Kong
    Yu, KN
    Cheung, T
    Guan, ZJ
    Young, ECM
    Mui, BWN
    Wong, YY
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1999, 45 (03) : 291 - 308
  • [7] A study of 222Rn/220Rn exhalation rate and indoor 222Rn/220Rn levels in higher Himalayan terrain
    Sajwan, Rohit Singh
    Joshi, Veena
    Kumar, Naresh
    Ahamad, Taufiq
    Dutt, Sanjay
    Lavanya, Bevinathalapura Shankarappa Kempalingappa
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (11-12) : 1018 - 1026
  • [8] 222Rn and 220Rn diffusion in two mediums
    Markovic, V. M.
    Nikezic, D.
    Stevanovic, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 857 : 16 - 23
  • [9] A study of indoor 220Rn and 222Rn decay product concentrations in the UK
    Proctor, L. A.
    RADIATION PROTECTION DOSIMETRY, 2006, 121 (02) : 175 - 178
  • [10] Instrument for continuous measurement of 220Rn (and 222Rn) using delayed coincidences between 220Rn and 216Po
    Bigu, J.
    Elliott, J.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A344 (02) : 415 - 425