NEMA NU 4-2008 and in vivo imaging performance of RAYCAN trans-PET/CT X5 small animal imaging system

被引:8
|
作者
Teuho, J. [1 ,2 ,3 ]
Han, C. [1 ,2 ]
Riehakainen, L. [1 ,2 ]
Honkaniemi, A. [1 ,2 ]
Tirri, M. [1 ,2 ,7 ]
Liljenback, H. [1 ,2 ]
Virta, J. [1 ,2 ]
Gu, S. [4 ]
Liu, S. [5 ]
Wan, L. [6 ]
Teras, M. [3 ,7 ]
Roivainen, A. [1 ,2 ]
Xie, Q. [8 ]
Knuuti, J. [1 ,2 ]
机构
[1] Univ Turku, Turku PET Ctr, Turku, Finland
[2] Turku Univ Hosp, Turku, Finland
[3] Turku Univ Hosp, Dept Med Phys, Div Med Imaging, Turku, Finland
[4] RAYCAN Technol Co Ltd, Suzhou, Peoples R China
[5] RaySolut Digital Med Imaging Co Ltd, Ezhou, Peoples R China
[6] RayData Technol Co Ltd, Wuhan, Hubei, Peoples R China
[7] Univ Turku, Dept Biomed, Turku, Finland
[8] Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan, Hubei, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 11期
基金
芬兰科学院;
关键词
small-animal PET/CT system; performance evaluation; NEMA; preclinical PET imaging; INITIAL PERFORMANCE; MICROPET SCANNER; DESIGN; RESOLUTION;
D O I
10.1088/1361-6560/ab1856
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The RAYCAN Trans-PET/CT X5 is a preclinical positron emission tomography and computed tomography (PET/CT) system intended for in vivo imaging of rats and mice, featuring all-digital readout electronics for PET data acquisition. The National Electrical Manufacturers Association (NEMA) NU 4-2008 performance evaluation was conducted on the RAYCAN Trans-PET/CT X5 in addition to assessing in vivo imaging performance of the system on live animals. The performance characteristics of the system were evaluated, including system spatial resolution, count rate performance, sensitivity and image quality. The system imaging performance is assessed in dynamic in vivo PET imaging. The system resolution defined as full width half maximum (FWHM) was 2.07 mm, 2.11 mm and 1.31 mm for the tangential, radial and axial resolution, respectively, at the center of the field of view. The peak noise equivalent count rate (NECR) values measured were 61 kcps at 0.19 MBq ml(-1) for the rat size phantom and 126 kcps at 1.53 MBq ml(-1) for the mouse size phantom. Scatter fractions were 24% and 14% for the rat and mouse phantom. The measured peak sensitivity of the system was 1.70%. Image quality in static imaging was deemed sufficient based on the image quality phantom study, with average activity concentration of 155 +/- 8.6 kBq ml(-1) and image uniformity of 5.57% when using two-dimensional filtered backprojection algorithm (2D-FBP). Rods in the image quality phantom were visualized easily up to 2 mm in size. In dynamic in vivo PET imaging, time-activity-curves from several regions were successfully measured, characterizing the radioactivity distribution in myocardial blood pool, liver, left ventricle and the lung. In conclusion, the RAYCAN Trans-PET/CT X5 system can be considered a suitable option for basic imaging needs in preclinical imaging.
引用
收藏
页数:13
相关论文
共 26 条
  • [1] NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems
    Goertzen, Andrew L.
    Bao, Qinan
    Bergeron, Melanie
    Blankemeyer, Eric
    Blinder, Stephan
    Canadas, Mario
    Chatziioannou, Arion F.
    Dinelle, Katherine
    Elhami, Esmat
    Jans, Hans-Sonke
    Lage, Eduardo
    Lecomte, Roger
    Sossi, Vesna
    Surti, Suleman
    Tai, Yuan-Chuan
    Jose Vaquero, Juan
    Vicente, Esther
    Williams, Darin A.
    Laforest, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1300 - 1309
  • [2] Technical Note: Performance evaluation of a small-animal PET/CT system based on NEMA NU 4-2008 standards
    Liu, Qiong
    Li, Chaofan
    Liu, Jiguo
    Krish, Kishore
    Fu, Xinlei
    Zhao, Jie
    Chen, Jyh-Cheng
    MEDICAL PHYSICS, 2021, 48 (09) : 5272 - 5282
  • [3] Performance Evaluation of a PEM Scanner Using the NEMA NU 4-2008 Small Animal PET Standards
    Luo, Weidong
    Anashkin, Edward
    Matthews, Christopher G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 94 - 103
  • [4] Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards
    Sato, K.
    Shidahara, M.
    Watabe, H.
    Watanuki, S.
    Ishikawa, Y.
    Arakawa, Y.
    Nai, Y. H.
    Furumoto, S.
    Tashiro, M.
    Shoji, T.
    Yanai, K.
    Gonda, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 696 - 711
  • [5] NEMA NU 4-2008 performance evaluation and MR compatibility tests of an APD-based small animal PET-insert for simultaneous PET/MR imaging
    Disselhorst, Jonathan A.
    Newport, Danny F.
    Schmid, Andreas M.
    Schmidt, Fabian P.
    Parl, Christoph
    Liu, Chih-Chieh
    Pichler, Bernd J.
    Mannheim, Julia G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (04):
  • [6] Performance evaluation of a small-animal PET scanner with 213 mm axis using NEMA NU 4-2008
    Wei, Qing
    Wang, Yingjie
    Huang, Xianchao
    Li, Daowu
    Zheng, Yushuang
    Wang, Peilin
    Sun, Xiaoli
    Chai, Pei
    Han, Xiaorou
    Liu, Shuangquan
    Feng, Baotong
    Zhou, Wei
    Zeng, Xiangtao
    Zhu, Meiling
    Zhang, Zhiming
    Wei, Long
    MEDICAL PHYSICS, 2024,
  • [7] Comments on the NEMA NU 4-2008 Standard on Performance Measurement of Small Animal Positron Emission Tomographs
    Patrick Hallen
    David Schug
    Volkmar Schulz
    EJNMMI Physics, 7
  • [8] Comments on the NEMA NU 4-2008 Standard on Performance Measurement of Small Animal Positron Emission Tomographs
    Hallen, Patrick
    Schug, David
    Schulz, Volkmar
    EJNMMI PHYSICS, 2020, 7 (01)
  • [9] NEMA NU 4-2008 Performance Measurements of Two Commercial Small-Animal PET Scanners: ClearPET and rPET-1
    Canadas, Mario
    Embid, Miguel
    Lage, Eduardo
    Desco, Manuel
    Jose Vaquero, Juan
    Manuel Perez, Jose
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 58 - 65
  • [10] Monte Carlo simulations versus experimental measurements in a small animal PET system. A comparison in the NEMA NU 4-2008 framework
    Popota, F. D.
    Aguiar, P.
    Espana, S.
    Lois, C.
    Udias, J. M.
    Ros, D.
    Pavia, J.
    Gispert, J. D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01): : 151 - 162