Approaching ultimate intrinsic specific absorption rate in radiofrequency shimming using high-permittivity materials at 7 Tesla

被引:10
|
作者
Haemer, Gillian G. [1 ,2 ,3 ,4 ]
Vaidya, Manushka [1 ,2 ,3 ,4 ]
Collins, Christopher M. [1 ,2 ,3 ,4 ]
Sodickson, Daniel K. [1 ,2 ,3 ,4 ]
Wiggins, Graham C. [1 ,2 ]
Lattanzi, Riccardo [1 ,2 ,3 ,4 ]
机构
[1] NYU, Sch Med, CAI2R, New York, NY USA
[2] NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, New York, NY USA
[3] NYU, NYU WIRELESS, Tandon Sch Engn, Brooklyn, NY USA
[4] NYU, Sch Med, Sackler Inst Grad Biomed Sci, New York, NY USA
基金
美国国家科学基金会;
关键词
Ultimate intrinsic SAR; RF shimming; transmit array; high permittivity material; global SAR; TO-NOISE RATIO; FIELD INHOMOGENEITY; POWER DEPOSITION; DIELECTRIC PADS; GLOBAL SAR; EXCITATION; MRI; HOMOGENEITY; ARRAY; COIL;
D O I
10.1002/mrm.27022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe aim of this study was to evaluate the effect of integrated high-permittivity materials (HPMs) on excitation homogeneity and global specific absorption rate (SAR) for transmit arrays at 7T. MethodsA rapid electrodynamic simulation framework was used to calculate L-curves associated with excitation of a uniform 2D profile in a dielectric sphere. We used ultimate intrinsic SAR as an absolute performance reference to compare different transmit arrays in the presence and absence of a layer of HPM. We investigated the optimal permittivity for the HPM as a function of its thickness, the sample size, and the number of array elements. ResultsAdding a layer of HPM can improve the performance of a 24-element array to match that of a 48-element array without HPM, whereas a 48-element array with HPM can perform as well as a 64-element array without HPM. Optimal relative permittivity values changed based on sample and coil geometry, but were always within a range obtainable with readily available materials (epsilon(r)=100-200). ConclusionIntegration of HPMs could be a practical method to improve RF shimming performance, alternative to increasing the number of coils. The proposed simulation framework could be used to explore the design of novel transmit arrays for head imaging at ultra-high field strength. Magn Reson Med 80:391-399, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:391 / 399
页数:9
相关论文
共 6 条
  • [1] Passive Radiofrequency Shimming in the Thighs at 3 Tesla Using High Permittivity Materials and Body Coil Receive Uniformity Correction
    Brink, Wyger M.
    Versluis, Maarten J.
    Peeters, Johannes M.
    Boernert, Peter
    Webb, Andrew G.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (06) : 1951 - 1956
  • [2] Manipulating transmit and receive sensitivities of radiofrequency surface coils using shielded and unshielded high-permittivity materials
    Vaidya, Manushka V.
    Deniz, Cem M.
    Collins, Christopher M.
    Sodickson, Daniel K.
    Lattanzi, Riccardo
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (03) : 355 - 366
  • [3] Manipulating transmit and receive sensitivities of radiofrequency surface coils using shielded and unshielded high-permittivity materials
    Manushka V. Vaidya
    Cem M. Deniz
    Christopher M. Collins
    Daniel K. Sodickson
    Riccardo Lattanzi
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 355 - 366
  • [4] The effect of high-permittivity pads on specific absorption rate in radiofrequency-shimmed dual-transmit cardiovascular magnetic resonance at 3T
    Wyger M. Brink
    Johan S. van den Brink
    Andrew G. Webb
    Journal of Cardiovascular Magnetic Resonance, 17
  • [5] The effect of high-permittivity pads on specific absorption rate in radiofrequency-shimmed dual-transmit cardiovascular magnetic resonance at 3T
    Brink, Wyger M.
    van den Brink, Johan S.
    Webb, Andrew G.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [6] Fast Low-Specific Absorption Rate B0-Mapping along Projections at High Field Using Two-Dimensional Radiofrequency Pulses
    Reynaud, Olivier
    Gallichan, Daniel
    Schaller, Benoit
    Gruetter, Rolf
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 901 - 908