NUMERICAL PREDICTION OF PARTICULATE FLOW OVER A BACKWARD-FACING STEP FOLLOWED BY A FILTER MEDIUM

被引:0
|
作者
Dange, A. K. [1 ]
Ravi, K. C. [1 ]
Chambers, F. W. [1 ]
机构
[1] Rupture Pin Technol Inc, Oklahoma City, OK 73128 USA
关键词
TURBULENT-FLOW; INCOMPRESSIBLE-FLOW; POROUS INSERT; PIV;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Flow in air filter housings often is characterized by separation upstream of the filter. The effect of the separation on the motion of particles and their distribution at the filter is important to filter performance. The current research investigates these effects by applying CFD modeling to turbulent particulate flows over a backward-facing step followed by a porous medium representing a filter. The two-dimensional step flow was selected as it is an archetype for separated flow with many studies in the literature. The flow examined has a step expansion ratio of 1:2, with an entrance length of 30 step heights to the step followed by a length of 60 step heights. Computations were performed at step Reynolds numbers of 6550 and 10,000 for the step without a porous medium and with the medium placed 4.25 and 6.75 step heights downstream of the step. The mesh was developed in ICEM CFD and modeling was done using the Fluent commercial CFD package. The carrier phase turbulence was modeled using the RNG k-epsilon model. The particles were modeled using the discrete phase model with dispersion modeled using stochastic tracking. The boundary conditions are uniform velocity at the inlet, no-slip at the walls, porous jump at the porous medium, and outflow at the outlet. The particle boundary condition is "reflect" at the walls and "trap" at the filter. The numerical results for the no filter case matched experimental results for recirculation zone length and velocity profiles at 3.75 and 6.25 step heights well. The computed velocity profiles at 3.75 step heights do not match experimental profiles for the filter at 4.25 step heights so well, though the results show a profound effect on the recirculation zone length, matching the experiments. Differences are attributed to different velocity profiles at the step. With the medium 6.75 step heights downstream, the effect on the recirculation zone is negligible, again matching experimental results. The discrete phase model tracks injected particles and provides results which are qualitatively similar to the literature. It is observed that particles with lower Stokes number, and thus lower momentum, tend to follow the flow and enter the recirculation zone while particles with higher Stokes number tend to move directly to the porous medium. When the filter is moved downstream to 6.75 step heights, the increased length of the recirculation zone results in more particles entering the recirculation zone. Results for monodispersed and polydispersed particles agree.
引用
收藏
页码:297 / 306
页数:10
相关论文
共 50 条
  • [1] A NUMERICAL STUDY OF FLOW OVER A CONFINED BACKWARD-FACING STEP
    BARTON, IE
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 1995, 21 (08) : 653 - 665
  • [2] Numerical investigation of flow over obstacles on a backward-facing step
    Bayraktar, Seyfettin
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2021, 36 (02): : 1145 - 1158
  • [3] Computation of dilute particulate laminar flow over a backward-facing step
    Barton, IE
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 1996, 22 (03) : 211 - 221
  • [4] Direct numerical simulation of turbulent flow over a backward-facing step
    Le, H
    Moin, P
    Kim, J
    JOURNAL OF FLUID MECHANICS, 1997, 330 : 349 - 374
  • [5] Numerical simulation and stability analysis of flow over a backward-facing step
    Liao, Jiefang
    Zhang, Wei
    Chen, Guoping
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLIED SCIENCE AND ENGINEERING INNOVATION, 2015, 12 : 301 - 304
  • [6] A numerical revisit of backward-facing step flow problem
    Chiang, TP
    Sheu, TWH
    PHYSICS OF FLUIDS, 1999, 11 (04) : 862 - 874
  • [7] Turbulent flow over a rough backward-facing step
    Wu, Yanhua
    Ren, Huiying
    Tang, Hui
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2013, 44 : 155 - 169
  • [8] Ventilated cavity flow over a backward-facing step
    Pearce, B. W.
    Brandner, P. A.
    Foster, S. J.
    9TH INTERNATIONAL SYMPOSIUM ON CAVITATION (CAV2015), 2015, 656
  • [9] Numerical simulation of a swept backward-facing step flow
    Jiang, Lijun
    Gao, Ge
    Zhang, Changxian
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2010, 36 (01): : 87 - 90
  • [10] Particulate flow over a backward facing step
    Alani, A
    Barton, IE
    Seymour, MJ
    Wrobel, LC
    PROCEEDINGS OF THE SECOND NSF INTERNATIONAL CONFERENCE ON INDOOR AIR HEALTH: TRENDS AND ADVANCES IN RISK ASSESSMENT AND MANAGEMENT, 2001, : 165 - 173