Monte Carlo Dose Calculations in Homogeneous and Heterogeneous Media: A Comparison between the PMCEPT code and the MCNP5, EGS4, DPM codes, and Experiments

被引:0
|
作者
Kum, Oyeon [1 ]
机构
[1] Pohang Univ Sci & Technol, Combinatorial & Computat Math Ctr, Pohang 790784, South Korea
关键词
Customized radiation therapy planning simulation system; PMCEPT code; Monte Carlo; Proton therapy;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Monte Carlo method for coupled photon and charged particle transport is the most accurate means for predicting absorbed dose distributions in radiotherapy. However, the large amount of computing time required by general purpose Monte Carlo codes has prevented their routine uses of dose calculations for customized radiation treatment planning in spite of the rapid development of computer hardware and network technologies. This difficulty could be solved by either using faster computers or introducing new calculation techniques or both. The parallel Monte Carlo electron and photon transport (PMCEPT) code [Kum and Lee, J. Kor. Phys. Soc. 47 (2005) 716] for calculating electron and photon beam doses has been developed based on the three dimensional geometry defined by computerized tomography (CT) images and implemented on a Beowulf PC cluster. The PMCEPT code was validated on the homogeneous and multi-layered targets for megavoltage electron beams by comparing with the results of experiments and calculations from conventional Monte Carlo codes such as the MCNP5, EGS4, and DPM. The computing time benchmark result showed that the PMCEPT code was approximately twenty times faster than that of MCNP5 on the IBM ThinkPad X40 (laptop) with 1.2-GHz CPU and 512-MB RAM memory operated by RedHat Linux 9. Overall, the PMCEPT results agreed well with others in homogeneous and heterogeneous media within a maximum of 2--3% error. The capability of the PMCEPT code is being enhanced to include therapeutic proton beam simulations with a simpler Bethe-Block relative proton stopping power formula.
引用
收藏
页码:1859 / 1862
页数:4
相关论文
共 15 条
  • [1] Monte Carlo dose calculations in homogeneous and heterogeneous media: A comparison between the PMCEPT code and the MCNP5, EGS4, DPM codes and measurements
    Kum, O.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2122 - 2122
  • [2] Monte Carlo dose calculations of beta-emitting sources for intravascular brachytherapy: A comparison between EGS4, EGSnrc, and MCNP
    Wang, RQ
    Li, XA
    [J]. MEDICAL PHYSICS, 2001, 28 (02) : 134 - 141
  • [3] Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses
    Love, PA
    Lewis, DG
    Al-Affan, IAM
    Smith, CW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05): : 1351 - 1357
  • [4] Monte Carlo dose calculations in homogeneous media and at interfaces: A comparison between GEPTS, EGSnrc, MCNP, and measurements
    Chibani, O
    Li, XA
    [J]. MEDICAL PHYSICS, 2002, 29 (05) : 835 - 847
  • [5] Comparison of synchrotron radiation calculations between analytical codes (STAC8, PHOTON) and Monte Carlo codes (FLUKA, EGS4)
    Liu, JC
    Fasso, A
    Prinz, A
    Rokni, S
    Asano, Y
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 658 - 661
  • [6] Benchmark dose calculations of MCNP5 and PENELOPE codes: Accuracy of low-energy photon cross-sections in Monte Carlo dose calculations
    Ye, S
    Naqvi, S
    Brezovich, I
    Pareek, P
    Popple, R
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1731 - 1731
  • [7] Verification of radiation dose calculations during paediatric cystourethrography examinations using MCNP5 and PCXMC 2.0 Monte Carlo codes
    Yakoumakis, E.
    Dimitriadis, A.
    Makri, T.
    Karlatira, M.
    Karavasilis, E.
    Gialousis, G.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 157 (03) : 355 - 362
  • [8] Comparison of EGS4 and MCNP4b Monte Carlo codes for generation of photon phase space distributions for a Varian 2100C
    Siebers, JV
    Keall, PJ
    Libby, B
    Mohan, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12): : 3009 - 3026
  • [9] Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources
    Chiavassa, S
    Lemosquet, A
    Aubineau-Lanièce, I
    de Carlan, L
    Clairand, I
    Ferrer, L
    Bardiès, M
    Franck, D
    Zankl, M
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 631 - 635
  • [10] Monte Carlo calculations of electrons impinging on a copper target: A comparison of EGSnrc, Geant4 and MCNP5
    Archambault, John Paul
    [J]. APPLIED RADIATION AND ISOTOPES, 2018, 132 : 129 - 134