Off-axis response due to mechanical coupling across all six degrees of freedom in the human disc

被引:11
|
作者
DeLucca, John F. [1 ]
Amin, Dhara [2 ]
Peloquin, John M. [1 ]
Vresilovic, Edward J. [3 ]
Costi, John J. [2 ]
Elliott, Dawn M. [1 ]
机构
[1] Univ Delaware, Dept Biomed Engn, 161 Colburn Lab, Newark, DE 19716 USA
[2] Flinders Univ S Australia, Coll Sci & Engn, Med Device Res Inst, Biomech & Implants Res Grp, Adelaide, SA, Australia
[3] UPMC Pinnacle, Lititz, PA USA
来源
JOR SPINE | 2019年 / 2卷 / 01期
基金
美国国家卫生研究院;
关键词
coupled motion; hybrid control; intervertebral disc; off-axis; spine loading; HUMAN LUMBAR SPINE; IN-VIVO LOADS; INTERVERTEBRAL DISC; MOTION; TORSION; BIOMECHANICS; BEHAVIOR; RANGE; SHAPE; SIZE;
D O I
10.1002/jsp2.1047
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The kinematics of the intervertebral disc are defined by six degrees of freedom (DOF): three translations (Tz: axial compression, Tx: lateral shear, and Ty: anterior-posterior shear) and three rotations (Rz: torsion, Rx: flexion-extension, and Ry: lateral bending). There is some evidence that the six DOFs are mechanically coupled, such that loading in one DOF affects the mechanics of the other five "off-axis" DOFs, however, most studies have not controlled and/or measured all six DOFs simultaneously. Additionally, the relationships between disc geometry and disc mechanics are important for evaluation of data from different sized donor and patient discs. The objectives of this study were to quantify the mechanical behavior of the intervertebral disc in all six degrees of freedom (DOFs), measure the coupling between the applied motion in each DOF with the resulting off-axis motions, and test the hypothesis that disc geometry influences these mechanical behaviors. All off-axis displacements and rotations were significantly correlated with the applied DOF and were of similar magnitude as physiologically relevant motion, confirming that off-axis coupling is an important mechanical response. Interestingly, there were pairs of DOFs that were especially strongly coupled: lateral shear (Tx) and lateral bending (Ry), anterior-posterior shear (Ty) and flexion-extension (Rx), and compression (Tz) and torsion (Rz). Large off-axis shears may contribute to injury risk in bending and flexion. In addition, the disc responded to shear (Tx, Ty) and rotational loading (Rx, Ry, and Rz) by increasing in disc height in order to maintain the applied compressive load. Quantifying these mechanical behaviors across all six DOF are critical for designing and testing disc therapies, such as implants and tissue engineered constructs, and also for validating finite element models.
引用
收藏
页数:10
相关论文
共 9 条
  • [1] THEORETICAL OFF-AXIS MECHANICAL RESPONSE OF IDEALIZED UNIDIRECTIONAL COMPOSITES
    KARLAK, RF
    CROSSMAN, FW
    JOM-JOURNAL OF METALS, 1975, 27 (12): : A37 - A37
  • [2] Six-degrees-of-freedom alignment of two-dimensional arrays components by use of off-axis linear Fresnel zone plates
    Ayliffe, MH
    Châteauneuf, M
    Rolston, DR
    Kirk, AG
    Plant, DV
    APPLIED OPTICS, 2001, 40 (35) : 6515 - 6526
  • [3] Nonlinear Mechanical Response of CFRP Laminates under Off-Axis Tensile Loading
    Ogihara, Shinji
    SCIENCE AND ENGINEERING OF COMPOSITE MATERIALS, 2010, 17 (02): : 133 - 141
  • [4] Mechanical testing of cancellous bone from the femoral head:: Experimental errors due to off-axis measurements
    Oehman, Caroline
    Baleani, Massimiliano
    Perilli, Egon
    Dall'Ara, Enrico
    Tassani, Simone
    Baruffaldi, Fabio
    Viceconti, Marco
    JOURNAL OF BIOMECHANICS, 2007, 40 (11) : 2426 - 2433
  • [5] Six degrees of freedom vibration transmissibility measurement of flexural opto-mechanical structures with 3-axis acceleration sensors
    Yuan Wen-quan
    Wu Zhi-hui
    Sui Yong-xin
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2014, 38 (03): : 561 - 568
  • [6] Influence of Mechanical Deformation of Off-Axis Optical Path on Coupling Efficiency in 3D Micro-Vibration Measurement
    Dong Hui
    Wang Dayong
    Kong Xinxin
    Wang Yunxin
    ACTA OPTICA SINICA, 2023, 43 (10)
  • [7] EFFECTS OF FIBER/MATRIX ADHESION ON OFF-AXIS MECHANICAL RESPONSE IN CARBON-FIBER/EPOXY-RESIN COMPOSITES
    HOECKER, F
    FRIEDRICH, K
    BLUMBERG, H
    KARGERKOCSIS, J
    COMPOSITES SCIENCE AND TECHNOLOGY, 1995, 54 (03) : 317 - 327
  • [8] Effect of multiaxiality, stacking sequence and number of off-axis layers on the mechanical response and damage sequence of carbon/epoxy composite laminates under static loading
    Kalteremidou, Kalliopi-Artemi
    Hajikazemi, Mohammad
    Van Paepegem, Wim
    Van Hemelrijck, Danny
    Pyl, Lincy
    COMPOSITES SCIENCE AND TECHNOLOGY, 2020, 190
  • [9] Efficacy of velocity feedback control for suppression of the friction-induced oscillation due to mode-coupling instability in a two degrees-of-freedom mechanical system
    Kumar, Gautam
    Malas, Anindya
    JOURNAL OF VIBRATION AND CONTROL, 2024, 30 (11-12) : 2490 - 2511