A Computational Model of a Microfluidic Device to Measure the Dynamics of Oxygen-Dependent ATP Release from Erythrocytes

被引:6
|
作者
Sove, Richard J. [1 ]
Ghonaim, Nour [2 ]
Goldman, Daniel [1 ,2 ]
Ellis, Christopher Gerald [1 ,2 ]
机构
[1] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[2] Univ Western Ontario, Biomed Engn Grad Program, London, ON, Canada
来源
PLOS ONE | 2013年 / 8卷 / 11期
关键词
RED-BLOOD-CELLS; FLOW; RESPONSES; TUBE; TONE;
D O I
10.1371/journal.pone.0081537
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Erythrocytes are proposed to be involved in blood flow regulation through both shear- and oxygen-dependent mechanisms for the release of adenosine triphosphate (ATP), a potent vasodilator. In a recent study, the dynamics of shear-dependent ATP release from erythrocytes was measured using a microfluidic device with a constriction in the channel to increase shear stress. The brief period of increased shear stress resulted in ATP release within 25 to 75 milliseconds downstream of the constriction. The long-term goal of our research is to apply a similar approach to determine the dynamics of oxygen-dependent ATP release. In the place of the constriction, an oxygen permeable membrane would be used to decrease the hemoglobin oxygen saturation of erythrocytes flowing through the channel This paper describes the first stage in achieving that goal, the development of a computational model of the proposed experimental system to determine the feasibility of altering oxygen saturation rapidly enough to measure ATP release dynamics. The computational model was constructed based on hemodynamics, molecular transport of oxygen and ATP, kinetics of luciferin/luciferase reaction for reporting ATP concentrations, light absorption by hemoglobin, and sensor characteristics. A linear model of oxygen saturation-dependent ATP release with variable time delay was used in this study. The computational results demonstrate that a microfluidic device with a 100 gm deep channel will cause a rapid decrease in oxygen saturation over the oxygen permeable membrane that yields a measurable light intensity profile for a change in rate of ATP release from erythrocytes on a timescale as short as 25 milliseconds. The simulation also demonstrates that the complex dynamics of ATP release from erythrocytes combined with the consumption by luciferin/luciferase in a flowing system results in light intensity values that do not simply correlate with ATP concentrations. A computational model is required for proper interpretation of experimental data.
引用
收藏
页数:9
相关论文
共 22 条
  • [1] Computational Analysis of a Microfluidic Device for Measuring Oxygen-Dependent ATP Release from Erythrocytes
    Sove, Richard
    Ghonaim, Nour W.
    Ellis, Christopher G.
    Goldman, Daniel
    FASEB JOURNAL, 2012, 26
  • [2] Measurement and Analysis of the Dynamics of Erythrocyte Oxygen-Dependent ATP Release
    Sove, Richard
    Goldman, Daniel
    Fraser, Graham
    Ellis, Christopher
    FASEB JOURNAL, 2015, 29
  • [3] Oxygen Considerations in the Design of Microfluidics for Studying Oxygen Dependent ATP Release from Erythrocytes
    Sove, Richard J.
    Goldman, Daniel
    Fraser, Graham M.
    Ellis, Christopher G.
    FASEB JOURNAL, 2016, 30
  • [4] Role of oxygen-dependent ATP release by red blood cells in metabolic regulation of blood flow
    Arciero, JC
    Secomb, TW
    FASEB JOURNAL, 2006, 20 (04): : A278 - A278
  • [5] Roles of oxygen-dependent ATP release by red blood cells and conducted responses in metabolic regulation of blood flow
    Arciero, Julia C.
    Carlson, Brian E.
    Secomb, Timothy W.
    FASEB JOURNAL, 2007, 21 (05): : A479 - A479
  • [6] Use of microchip-based hydrodynamic focusing to measure the deformation-induced release of ATP from erythrocytes
    Moehlenbrock, Michael J.
    Price, Alexander K.
    Martin, R. Scott
    ANALYST, 2006, 131 (08) : 930 - 937
  • [7] Pannexin 1 is the conduit for low oxygen tension-induced ATP release from human erythrocytes
    Sridharan, Meera
    Adderley, Shaquria P.
    Bowles, Elizabeth A.
    Egan, Terrance M.
    Stephenson, Alan H.
    Ellsworth, Mary L.
    Sprague, Randy S.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2010, 299 (04): : H1146 - H1152
  • [8] Temperature-dependent release of ATP from human erythrocytes: mechanism for the control of local tissue perfusion
    Kalsi, Kameljit K.
    Gonzalez-Alonso, Jose
    EXPERIMENTAL PHYSIOLOGY, 2012, 97 (03) : 419 - 432
  • [9] Determination of ATP release from erythrocytes using microbore tubing as a model of resistance vessels in vivo
    Sprung, R
    Sprague, R
    Spence, D
    ANALYTICAL CHEMISTRY, 2002, 74 (10) : 2274 - 2278