Does increased acetabular depth affect safe infra-acetabular screw placement in acetabular fracture fixation?

被引:4
|
作者
Bastian, Johannes Dominik [1 ]
Naf, David Riccardo [1 ]
Cullmann, Jennifer Larissa [2 ]
Keel, Marius Johann [1 ]
Giannoudis, Peter V. [3 ]
机构
[1] Univ Bern, Univ Hosp Bern, Dept Orthopaed Surg & Traumatol, Inselspital Bern, Freiburgstr 18, CH-3010 Bern, Switzerland
[2] Univ Bern, Inselspital, Dept Diagnost Intervent & Paediat Radiol, Bern, Switzerland
[3] Univ Leeds, Sch Med, Acad Dept Trauma & Orthopaed, Leeds, W Yorkshire, England
关键词
Acetabulum; Fracture; Infra-acetabular screw; Depth; Quadrilateral plate; Lateral center-edge-angle; CORRIDOR; TILT;
D O I
10.1007/s00068-020-01455-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Infra-acetabular screws enhance the fixation strength in acetabular fractures with separation of both columns. Placement without iatrogenic femoral head violation is challenging. Purpose To assess the impact of the acetabular configuration, the patients' age and gender on safe infra-acetabulum screw insertion. Methods In 112 patients (69 females; mean age: 34 years, range 17-88;n = 200 hips), the lateral center-edge angle (LCE) was measured on radiographs. Using corresponding axial CT scans the residual distance from (the lateral border) of the screw to (the medial border of) the femoral head ("Screw-to-Femoral Head distance"; "RD_SFH") was determined. Statistical analysis was carried out using linear regression, multiple linear regression and normal distribution estimation. Results The mean (range) LCE angle was 30 degrees (7 degrees-51 degrees) and the mean (range) "RD_SFH" was 5 mm (1-14 mm). The linear regression model shows a significant linear relation between LCE and "RD_SFH" with a slope parameter of - 0.15 (pvalue < 0.0001), the Pearson correlation between LCE and "RD_SFH" is - 0.56 (CI [- 0.71, [- 0.40]). Age did not have a significant impact on the relation between LCE and "RD_SFH" (pvalue 0.85). Compared to male patients, in females, the intercept is 4.62 mm (pvalue 0.0005) less, the slope parameter is 0.09 (pvalue 0.029) larger. Conclusion The virtual possibility to place an infra-acetabular screw was given in all patients. An increasing depth of the acetabulum correlated with a decrease in residual distances. As hip joint cartilage thickness was not considered in measurements, intraoperative rule-out of screw mispositioning especially in deep acetabular sockets and females is still of utmost importance.
引用
收藏
页码:1319 / 1326
页数:8
相关论文
共 50 条
  • [1] Does increased acetabular depth affect safe infra-acetabular screw placement in acetabular fracture fixation?
    Johannes Dominik Bastian
    David Riccardo Näf
    Jennifer Larissa Cullmann
    Marius Johann Keel
    Peter V. Giannoudis
    European Journal of Trauma and Emergency Surgery, 2021, 47 : 1319 - 1326
  • [2] Finite element analysis of infra-acetabular screw fixation for the treatment of acetabular posterior column fracture
    Wang, Tingguang
    Zhao, Bei
    Yan, Jun
    Shao, Bin
    Mu, Weidong
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (03) : 623 - 634
  • [3] Finite element analysis of infra-acetabular screw fixation for the treatment of acetabular posterior column fracture
    Tingguang Wang
    Bei Zhao
    Jun Yan
    Bin Shao
    Weidong Mu
    International Orthopaedics, 2022, 46 : 623 - 634
  • [4] Ideal insertion point and projection of the infra-acetabular screw in acetabular fracture surgery
    Fukuoka, Shiro
    Yorimitsu, Masanori
    Uehara, Takenori
    Naniwa, Shuichi
    Hata, Toshiaki
    Sato, Kohei
    Noda, Tomoyuki
    Sato, Toru
    Ozaki, Toshifumi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (06):
  • [5] Infra-Acetabular Corridor-Technical Tip for an Additional Screw Placement to Increase the Fixation Strength of Acetabular Fractures
    Culemann, Ulf
    Marintschev, Ivan
    Gras, Florian
    Pohlemann, Tim
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (01): : 244 - 246
  • [6] Navigated or conventional acetabular surgery Comparison of positional accuracy exemplified by the infra-acetabular screw
    Pagano, Stefano
    Mueller, Karolina
    Alt, Volker
    Maderbacher, Guenther
    Holzapfel, Dominik E.
    Baumann, Florian
    Freigang, Viola
    UNFALLCHIRURGIE, 2024, 127 (01): : 44 - 53
  • [7] Biomechanical comparison of different acetabular plate systems and constructs - The role of an infra-acetabular screw placement and use of locking plates
    Marintschev, Ivan
    Gras, Florian
    Schwarz, Christoph E.
    Pohlemann, Tim
    Hofmann, Gunther O.
    Culemann, Ulf
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (04): : 470 - 474
  • [8] Analysis of computed tomography-based infra-acetabular morphometry to assess the feasibility of infra-acetabular screws
    Kanezaki, Shozo
    Miyazaki, Masashi
    Notani, Naoki
    Ishihara, Toshinobu
    Sakamoto, Tomonori
    Abe, Tetsutaro
    Kataoka, Masashi
    Tsumura, Hiroshi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (03) : 359 - 364
  • [9] CT-scan based anatomical study as a guidance for infra-acetabular screw placement
    Lu, Quanyi
    Zhou, Runtao
    Gao, Shichang
    Liang, Anlin
    Yang, Mingming
    Yang, Haitao
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [10] CT-scan based anatomical study as a guidance for infra-acetabular screw placement
    Quanyi Lu
    Runtao Zhou
    Shichang Gao
    Anlin Liang
    Mingming Yang
    Haitao Yang
    BMC Musculoskeletal Disorders, 22