Are there any differences in three-dimensional placental vascular indices obtained using conventional power Doppler and high-definition flow imaging?

被引:5
|
作者
Rizzo, Giuseppe [1 ,2 ]
Pietrolucci, Maria Elena [1 ,2 ]
Aiello, Eloisa [1 ]
Dijmeli, Estelle [1 ]
Bosi, Costanza [1 ]
Arduini, Domenico [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Obstet & Gynecol, I-00186 Rome, Italy
[2] Univ Roma Tor Vergata, Fetal Med Ctr Genoma, I-00186 Rome, Italy
来源
关键词
high definition Doppler imaging; power Doppler; three-dimensional Doppler angiography; three-dimensional ultrasound; placenta; ULTRASOUND; REPRODUCIBILITY; SONOGRAPHY; VOLUME; COLOR;
D O I
10.3109/14767058.2012.657274
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The purpose of this study was to determine whether there are differences in values and reproducibility of three-dimensional (3D) vascular indices obtained on placental volumes using power Doppler (PD) or high-definition flow imaging (HDFI) techniques. Methods: A prospective study was performed on 121 uncomplicated singleton pregnancies at 11 + 0 to 13 + 6 weeks of gestation. Two placental volumes were acquired from each pregnancy. Vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were then analyzed and compared. In order to assess the reproducibility of the measurements, two additional placental volumes obtained with both PD and HDFI were acquired in 31 pregnancies and the agreement assessed by intraclass correlation coefficients. Inter-observer variability was assessed by analyzing all the volumes by two observers blinded to each other's. Results: A significant relationship was observed between the vascular indices values obtained with the two techniques (VI Pearson's r = 0.891 p < 0.001; FI r = 0.769 p < 0.001; VFI r = 0.847 p < 0.001). The median values of VI, FI and VFI were significantly higher when obtained with HDFI imaging. In serial recordings, the ICCs resulted higher when volumes were acquired with HDFI rather than with PD techniques. Similarly, HDFI demonstrated a higher inter-observer reproducibility. Conclusions: 3D vascular indices calculated using HDFI are higher than those calculated using conventional PD. Although the relationship between the two methods is high, HDFI shows a better reproducibility suggesting its potential clinical application.
引用
收藏
页码:1664 / 1667
页数:4
相关论文
共 50 条
  • [1] Three-Dimensional Vascular Indices Calculated Using Conventional Power Doppler and High-Definition Flow Imaging Are There Differences?
    Luis Alcazar, Juan
    Kudla, Marek J.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (05) : 761 - 766
  • [2] Three-dimensional high-definition flow in the diagnosis of placental lakes
    Inubashiri, Eisuke
    Deguchi, Keizou
    Abe, Kiyotaka
    Saitou, Atushi
    Watanabe, Yukio
    Akutagawa, Noriyuki
    Kuroki, Katumaru
    Sugawara, Masaki
    Maeda, Nobuhiko
    [J]. JOURNAL OF MEDICAL ULTRASONICS, 2014, 41 (04) : 491 - 494
  • [3] Three-dimensional high-definition flow in the diagnosis of placental lakes
    Eisuke Inubashiri
    Keizou Deguchi
    Kiyotaka Abe
    Atushi Saitou
    Yukio Watanabe
    Noriyuki Akutagawa
    Katumaru Kuroki
    Masaki Sugawara
    Nobuhiko Maeda
    [J]. Journal of Medical Ultrasonics, 2014, 41 : 491 - 494
  • [4] Validation of Placental Vascular Sonobiopsy for Obtaining Representative Placental Vascular Indices by Three-Dimensional Power Doppler Ultrasonography
    Tuuli, M. G.
    Houser, M.
    Odibo, L.
    Huster, K.
    Macones, G. A.
    Odibo, A. O.
    [J]. PLACENTA, 2010, 31 (03) : 192 - 196
  • [5] Three-dimensional High-Definition color Doppler flow imaging and vascular tumor biopsy to assess complex ovarian mosses - a preliminary experience
    Czekierdowski, Artur
    Stachowicz, Norbert
    Danilos, Jaroslaw
    Kotarski, Jan
    [J]. PRZEGLAD MENOPAUZALNY, 2009, 8 (06): : 291 - 298
  • [6] Comparison of Placental Three-Dimensional Power Doppler Vascular Indices and Placental Volume in Pregnancies with Small for Gestational Age Neonates
    Chen, Sue-Jar
    Chen, Chie-Pein
    Sun, Fang-Ju
    Chen, Chen-Yu
    [J]. JOURNAL OF CLINICAL MEDICINE, 2019, 8 (10)
  • [7] Reproducibility of three-dimensional power Doppler placental vascular indices in pregnancies between 26 and 35 weeks
    Guimaraes Filho, Helio Antonio
    Mattar, Rosiane
    Araujo Junior, Edward
    Dias da Costa, Lavoisier Linhares
    de Mello Junior, Carlos Fernando
    Machado Nardozza, Luciano Marcondes
    Nowak, Paulo Martin
    Moron, Antonio Fernandes
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2011, 283 (02) : 213 - 217
  • [8] Reproducibility of three-dimensional power Doppler placental vascular indices in pregnancies between 26 and 35 weeks
    Hélio Antonio Guimarães Filho
    Rosiane Mattar
    Edward Araujo Júnior
    Lavoisier Linhares Dias da Costa
    Carlos Fernando de Mello Junior
    Luciano Marcondes Machado Nardozza
    Paulo Martin Nowak
    Antonio Fernandes Moron
    [J]. Archives of Gynecology and Obstetrics, 2011, 283 : 213 - 217
  • [9] : High-definition three-dimensional flow imaging in prenatal diagnosis of velamentous umbilical cord insertion
    Rodriguez, N.
    Suarez, N.
    Vasquez, A.
    Cantor, N.
    Rodriguez, N.
    Esquivel, A. L.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 204 - 204
  • [10] Three-dimensional high-definition flow imaging in prenatal diagnosis of a true umbilical cord knot
    Rodriguez, N.
    Angarita, A. M.
    Casasbuenas, A.
    Sarmiento, A.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (02) : 245 - 246