Upper-Limb Prosthetic Control using Wearable Multichannel Mechanomyography

被引:0
|
作者
Wilson, Samuel [1 ]
Vaidyanathan, Ravi [1 ]
机构
[1] Imperial Coll London, Dept Mech Engn, Exhibit Rd, London, England
关键词
MYOELECTRIC CONTROL; SCHEME;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we introduce a robust multi-channel wearable sensor system for capturing user intent to control robotic hands. The interface is based on a fusion of inertial measurement and mechanomyography (MMG), which measures the vibrations of muscle fibres during motion. MMG is immune to issues such as sweat, skin impedance, and the need for a reference signal that is common to electromyography (EMG). The main contributions of this work are: 1) the hardware design of a fused inertial and MMG measurement system that can be worn on the arm, 2) a unified algorithm for detection, segmentation, and classification of muscle movement corresponding to hand gestures, and 3) experiments demonstrating the real-time control of a commercial prosthetic hand (Bebionic Version 2). Results show recognition of seven gestures, achieving an offline classification accuracy of 83.5% performed on five healthy subjects and one transradial amputee. The gesture recognition was then tested in real time on subsets of two and five gestures, with an average accuracy of 93.3% and 62.2% respectively. To our knowledge this is the first applied MMG based control system for practical prosthetic control.
引用
收藏
页码:1293 / 1298
页数:6
相关论文
共 50 条
  • [1] A Review on Upper-Limb Myoelectric Prosthetic Control
    Iqbal, Nisheena V.
    Subramaniam, Kamalraj
    Asmi, Shaniba P.
    [J]. IETE JOURNAL OF RESEARCH, 2018, 64 (06) : 740 - 752
  • [2] Synergistic Upper-Limb Functional Muscle Connectivity Using Acoustic Mechanomyography
    Castillo, C. Sebastian Mancero
    Vaidyanathan, Ravi
    Atashzar, S. Farokh
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (08) : 2569 - 2580
  • [3] UPPER-LIMB PROSTHETIC USE IN SLOVENIA
    BURGER, H
    MARINCEK, C
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1994, 18 (01) : 25 - 33
  • [4] SENSORY FEEDBACK IN UPPER-LIMB PROSTHETIC SYSTEMS
    ROHLAND, TA
    [J]. INTER-CLINIC INFORMATION BULLETIN, 1974, 13 (09): : 1 - 8
  • [5] Upper-Limb Prosthetic Myocontrol: Two Recommendations
    Castellini, Claudio
    Bongers, Raoul M.
    Nowak, Markus
    van der Sluis, Corry K.
    [J]. FRONTIERS IN NEUROSCIENCE, 2016, 9
  • [6] Wireless wearable controller for upper-limb neuroprosthesis
    Wheeler, Christa A.
    Peckham, P. Hunter
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2009, 46 (02): : 243 - 256
  • [7] Ubiquitous Human Upper-Limb Motion Estimation using Wearable Sensors
    Zhang, Zhi-Qiang
    Wong, Wai-Choong
    Wu, Jian-Kang
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (04): : 513 - 521
  • [8] Wearable system for post stroke rehabilitation of the upper-limb
    Lo Russi, F.
    Tognetti, A.
    Giorgino, T.
    Quaglini, S.
    [J]. BIOMEDICINE & PHARMACOTHERAPY, 2006, 60 (08) : 473 - 474
  • [9] Toward Improved Sensorimotor Integration and Learning Using Upper-limb Prosthetic Devices
    Gillespie, R. Brent
    Contreras-Vidal, Jose Luis
    Shewokis, Patricia A.
    Malley, Marcia K. O.
    Brown, Jeremy D.
    Agashe, Harshavardhan
    Gentili, Rodolphe
    Davis, Alicia
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5077 - 5080
  • [10] High-density force myography: A possible alternative for upper-limb prosthetic control
    Radmand, Ashkan
    Scheme, Erik
    Englehart, Kevin
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2016, 53 (04): : 443 - 456