Integrated Identification and Quantification of Cyanobacterial Toxins from Pacific Northwest Freshwaters by Liquid Chromatography and High-resolution Mass Spectrometry

被引:1
|
作者
Ahn, Soyoun [1 ,4 ]
Magana, Armando Alcazar [1 ]
Bozarth, Connie [2 ]
Shepardson, Jonathan [2 ]
Morre, Jeffery [1 ]
Dreher, Theo [2 ,3 ]
Maier, Claudia S. [1 ]
机构
[1] Oregon State Univ, Dept Chem, Gilbert Hall 153, Corvallis, OR 97331 USA
[2] Oregon State Univ, Dept Microbiol, Corvallis, OR 97331 USA
[3] Oregon State Univ, Ctr Genome Res & Biocomp, Corvallis, OR 97331 USA
[4] Enzychem Lifesci, Seoul 06775, South Korea
基金
美国国家卫生研究院;
关键词
high resolution mass spectrometry; TripleTOF; hybrid time-of-flight; microcystins; anatoxin; UHPLC; MICROCYSTIN-LR; ANATOXIN-A; LAKE WATER; ALGAL TOXINS; MS/MS METHOD; BLOOMS; EXTRACTION; NODULARIN; GENES; BIOSYNTHESIS;
D O I
10.29356/jmcs.v62i2.386
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The occurrence of harmful algal blooms in nutrient-rich freshwater bodies has increased worldwide, including in the Pacific Northwest. Some cyanobacterial genera have the potential to produce secondary metabolites that are highly toxic to humans, livestock and wildlife. Reliable methods for the detection of cyanobacterial toxins with high specificity and low limits of detection are in high demand. Here we test a relatively new hybrid high resolution accurate mass quadrupole time-of-flight mass spectrometry platform (TripleTOF) for the analysis of cyanobacterial toxins in freshwater samples. We developed a new method that allows the quantitative analysis of four commonly observed microcystin congeners (LR, LA, YR, and RR) and anatoxin-a in a 6-min LC run without solid-phase enrichment. Limits of detection for the microcystin congeners (LR, LA, YR, and RR) and anatoxin-a were <5 ng/L (200-fold lower than the guideline value of 1 mu g/L as maximum allowable concentration of MC-LR in drinking water). The method was applied for screening freshwaters in the Pacific Northwest during the bloom and post-bloom periods. The use of high resolution mass spectrometry and concomitant high sensitivity detection of specific fragment ions with high mass accuracy provides an integrated approach for the simultaneous identification and quantification of cyanobacterial toxins. The method is sensitive enough for detecting the toxins in single Microcystis colonies.
引用
收藏
页码:197 / 213
页数:17
相关论文
共 50 条
  • [1] Impurity identification and quantification for arginine vasopressin by liquid chromatography/high-resolution mass spectrometry
    Wu, Peize
    Ye, Sijian
    Li, Ming
    Li, Hongmei
    Kan, Ying
    Yang, Zecheng
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (12)
  • [2] Structurally related peptide impurity identification and accurate quantification for synthetic oxytocin by liquid chromatography–high-resolution mass spectrometry
    Ming Li
    Ralf D. Josephs
    Adeline Daireaux
    Tiphaine Choteau
    Steven Westwood
    Gustavo Martos
    Robert I. Wielgosz
    Hongmei Li
    [J]. Analytical and Bioanalytical Chemistry, 2021, 413 : 1861 - 1870
  • [3] Adduct annotation in liquid chromatography/high-resolution mass spectrometry to enhance compound identification
    Thomas Stricker
    Ron Bonner
    Frédérique Lisacek
    Gérard Hopfgartner
    [J]. Analytical and Bioanalytical Chemistry, 2021, 413 : 503 - 517
  • [4] Adduct annotation in liquid chromatography/high-resolution mass spectrometry to enhance compound identification
    Stricker, Thomas
    Bonner, Ron
    Lisaek, Frederique
    Hopfgartner, Gerard
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (02) : 503 - 517
  • [5] Liquid chromatography coupled to high-resolution mass spectrometry for nut classification and marker identification
    Campmajo, Guillem
    Saurina, Javier
    Nunez, Oscar
    [J]. FOOD CONTROL, 2023, 152
  • [6] Identification of metabolites in Withania sominfera fruits by liquid chromatography and high-resolution mass spectrometry
    Bolleddula, Jayaprakasam
    Fitch, William
    Vareed, Shaiju K.
    Nair, Muraleedharan G.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (11) : 1277 - 1290
  • [7] Rapid quantification of insulin degludec by immunopurification combined with liquid chromatography high-resolution mass spectrometry
    Gemma Reverter-Branchat
    Michael Groessl
    Christos T Nakas
    Jean-Christophe Prost
    Kwasi Antwi
    Eric E. Niederkofler
    Lia Bally
    [J]. Analytical and Bioanalytical Chemistry, 2020, 412 : 8351 - 8359
  • [8] Rapid quantification of insulin degludec by immunopurification combined with liquid chromatography high-resolution mass spectrometry
    Reverter-Branchat, Gemma
    Groessl, Michael
    Nakas, Christos T.
    Prost, Jean-Christophe
    Antwi, Kwasi
    Niederkofler, Eric E.
    Bally, Lia
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (30) : 8351 - 8359
  • [9] Impurities identification and quantification for calcitonin salmon by liquid chromatography-high resolution mass spectrometry
    Wu, Peize
    Li, Ming
    Kan, Ying
    Wu, Xue
    Li, Hongmei
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 186
  • [10] Liquid chromatography–high-resolution mass spectrometry for palytoxins in mussels
    Patrizia Ciminiello
    Carmela Dell’Aversano
    Emma Dello Iacovo
    Martino Forino
    Luciana Tartaglione
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 1463 - 1473