In the present work, modelization and plant dimension for batch reverse osmosis (RO) purification of olive mill wastewater from a two-phase olive oil mill (OMW2) is carried out through analysis of the fouling build-up the by means of the threshold flux theory, for fouling control and appropriate plant dimension. Inhibition and control of fouling is vital to definitely achieve the competitiveness of membrane technology at industrial scale. The fouling index was found to considerably increase when shifting the P-TM from 20 to 30 bar, that is, 31.3 %. However, there is no significant difference with regard to the fouling build-up within the range 10 - 20 bar. Therefore, it is recommended to work upon an operating pressure (P-TM) around 20 bar to maximize both the productivity (13.3 - 13.5 L h(-1)m(-2)) together with the rejection efficiency (R-COD, %) whereas on the other hand minimizing the flux decay during the operation time. Finally, a required membrane area (A(m)) equal to 95 m(2), that means an overdesign of 48%, is calculated on the basis of the obtained results at a P-TM of 20 bar. Finally, the compliance of the standards to reuse the purified effluent for irrigation purposes throughout the proposed treatment process was checked. At this operating pressure value, the organic matter rejection efficiency reaches 90.5 %, thus permitting reusing the final treated effluent in the proper olive oil production process to close the loop at industrial scale.
引用
收藏
页码:403 / 408
页数:6
相关论文
共 50 条
  • [1] Optimization study of the fouling build-up on a RO membrane for pretrated olive mill wastewater purification
    Ochando-Pulido J.M.
    Stoller M.
    Martínez-Férez A.
    [J]. Ochando-Pulido, Javier M. (jmochandop@ugr.es), 1600, Italian Association of Chemical Engineering - AIDIC (60): : 247 - 252
  • [2] Threshold performance of a spiral-wound reverse osmosis membrane in the treatment of olive mill effluents from two-phase and three-phase extraction processes
    Ochando-Pulido, J. M.
    Stoller, M.
    Di Palma, L.
    Martinez-Ferez, A.
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2014, 83 : 64 - 70
  • [3] Analysis of the concentration polarization and fouling dynamic resistances under reverse osmosis membrane treatment of olive mill wastewater
    Ochando-Pulido, J. M.
    Verardo, V.
    Segura-Carretero, A.
    Martinez-Ferez, A.
    [J]. JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 31 : 132 - 141
  • [4] Membrane fouling insight during reverse osmosis purification of pretreated olive mill wastewater
    Ochando-Pulido, J. M.
    Victor-Ortega, M. D.
    Martinez-Ferez, A.
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2016, 168 : 177 - 187
  • [5] Technical set-up of a reverse osmosis membrane unit in continuous operation for final purification of two-phase olive oil mill wastewater
    Ochando Pulido, Javier Miguel
    Victor Ortega, Maria Dolores
    Hodaifa Meri, Gassan
    Martinez Ferez, Antonio
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2016, 107 : 185 - 193
  • [6] Analysis of fouling resistances under dynamic filtration of pretreated olive mill wastewater on a loose reverse osmosis membrane
    Ochando-Pulido J.M.
    Stoller M.
    Martínez-Férez A.
    [J]. Ochando-Pulido, Javier Miguel (jmochandop@ugr.es), 1600, Italian Association of Chemical Engineering - AIDIC (57): : 1177 - 1182
  • [7] Fouling of a spiral-wound reverse osmosis membrane processing swine wastewater: effect of cleaning procedure on fouling resistance
    Camilleri-Rumbau, M. S.
    Masse, L.
    Dubreuil, J.
    Mondor, M.
    Christensen, K. V.
    Norddahl, B.
    [J]. ENVIRONMENTAL TECHNOLOGY, 2016, 37 (13) : 1704 - 1715
  • [8] Performances of Reverse Osmosis Membranes for Treatment of Olive Mill Wastewater
    Coskun, Tamer
    Yildirim, Asuman
    Balcik, Cigdem
    Demir, Neslihan Manav
    Debik, Eyup
    [J]. CLEAN-SOIL AIR WATER, 2013, 41 (05) : 463 - 468
  • [9] Fouling modelling on a reverse osmosis membrane in the purification of pretreated olive mill wastewater by adapted crossflow blocking mechanisms
    Ochando-Pulido, J. M.
    Martinez-Ferez, A.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2017, 544 : 108 - 118
  • [10] Treatment of Two-Phase Olive Mill Wastewater and Recovery of Phenolic Compounds Using Membrane Technology
    Sygouni, Varvara
    Pantziaros, Alexis G.
    Iakovides, Iakovos C.
    Sfetsa, Evangelia
    Bogdou, Polychronia I.
    Christoforou, Emilia A.
    Paraskeva, Christakis A.
    [J]. MEMBRANES, 2019, 9 (02)