Patient-specific in silico models can quantify primary implant stability in elderly human bone

被引:10
|
作者
Steiner, Juri A. [1 ]
Hofmann, Urs A. T. [1 ]
Christen, Patrik [1 ]
Favre, Jean M. [2 ]
Ferguson, Stephen J. [1 ]
van Lenthe, G. Harry [1 ,3 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomech, Vladimir Prelog Weg 3, CH-8093 Zurich, Switzerland
[2] CSCS Swiss Natl Supercomp Ctr, Via Trevano 131, CH-6900 Lugano, Switzerland
[3] KU Leuven Univ Leuven, Biomech Sect, Celestijnenlaan 300, B-3001 Leuven, Belgium
关键词
micro-CT; primary implant stability; patient-specific FEA; FINITE-ELEMENT-ANALYSES; MICRODAMAGE; VALIDATION; OSTEOPOROSIS; STRENGTH; FRACTURE; MICROSTRUCTURE; PREDICTION; MANAGEMENT; ACCURACY;
D O I
10.1002/jor.23721
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Secure implant fixation is challenging in osteoporotic bone. Due to the high variability in inter- and intra-patient bone quality, ex vivo mechanical testing of implants in bone is very material- and time-consuming. Alternatively, in silico models could substantially reduce costs and speed up the design of novel implants if they had the capability to capture the intricate bone microstructure. Therefore, the aim of this study was to validate a micro-finite element model of a multi-screw fracture fixation system. Eight human cadaveric humerii were scanned using micro-CT and mechanically tested to quantify bone stiffness. Osteotomy and fracture fixation were performed, followed by mechanical testing to quantify displacements at 12 different locations on the instrumented bone. For each experimental case, a micro-finite element model was created. From the micro-finite element analyses of the intact model, the patient-specific bone tissue modulus was determined such that the simulated apparent stiffness matched the measured stiffness of the intact bone. Similarly, the tissue modulus of a small damage region around each screw was determined for the instrumented bone. For validation, all in silico models were rerun using averaged material properties, resulting in an average coefficient of determination of 0.89 +/- 0.04 with a slope of 0.93 +/- 0.19 and a mean absolute error of 43 +/- 10m when correlating in silico marker displacements with the ex vivo test. In conclusion, we validated a patient-specific computer model of an entire organ bone-implant system at the tissue-level at high resolution with excellent overall accuracy. (c) 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:954-962, 2018.
引用
收藏
页码:954 / +
页数:9
相关论文
共 50 条
  • [2] A novel in silico method to quantify primary stability of screws in trabecular bone
    Steiner, Juri A.
    Christen, Patrik
    Affentranger, Remo
    Ferguson, Stephen J.
    van Lenthe, Gerrit Harry
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (11) : 2415 - 2424
  • [3] Restoration of Facial Bone Defect using Patient-Specific Implant
    Ha, Sung-Ho
    Choi, Jin-Young
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2022, 33 (07) : 2063 - 2066
  • [4] Patient-Specific Implant for Primary Orbital Reconstruction: A Case Report
    Jennifer, Ting
    Isa, Mohd Ferdaus
    Rajaran, Jothi Raamahlingam
    Nazimi, Abd Jabar
    [J]. ARCHIVES OF OROFACIAL SCIENCE, 2022, 17 (02): : 259 - 267
  • [5] Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models
    O'Rourke, Dermot
    Al-Dirini, Rami M. A.
    Taylor, Mark
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (03) : 1012 - 1023
  • [6] Patient-specific anatomical models in human physiology
    Vassilevski, Yuri V.
    Danilov, Alexander A.
    Gamilov, Timur M.
    Ivanov, Yuri A.
    Pryamonosov, Roman A.
    Simakov, Sergey S.
    [J]. RUSSIAN JOURNAL OF NUMERICAL ANALYSIS AND MATHEMATICAL MODELLING, 2015, 30 (03) : 185 - 201
  • [7] Synthetic skull bone defects for automatic patient-specific craniofacial implant design
    Li, Jianning
    Gsaxner, Christina
    Pepe, Antonio
    Morais, Ana
    Alves, Victor
    von Campe, Gord
    Wallner, Juergen
    Egger, Jan
    [J]. SCIENTIFIC DATA, 2021, 8 (01)
  • [8] Synthetic skull bone defects for automatic patient-specific craniofacial implant design
    Jianning Li
    Christina Gsaxner
    Antonio Pepe
    Ana Morais
    Victor Alves
    Gord von Campe
    Jürgen Wallner
    Jan Egger
    [J]. Scientific Data, 8
  • [9] Predisposing Factors for Orthodontic Mini-Implant Failure Defined by Bone Strains in Patient-Specific Finite Element Models
    Mhd Hassan Albogha
    Toru Kitahara
    Mitsugu Todo
    Hiroto Hyakutake
    Ichiro Takahashi
    [J]. Annals of Biomedical Engineering, 2016, 44 : 2948 - 2956
  • [10] Predisposing Factors for Orthodontic Mini-Implant Failure Defined by Bone Strains in Patient-Specific Finite Element Models
    Albogha, Mhd Hassan
    Kitahara, Toru
    Todo, Mitsugu
    Hyakutake, Hiroto
    Takahashi, Ichiro
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (10) : 2948 - 2956