A new technique for reconstruction of the common bile duct by an autologous vein graft and a biodegradable endoluminal stent

被引:31
|
作者
Heistermann, HP
Palmes, D
Stratmann, U
Hohlbach, G
Hierlemann, H
Langer, M
Spiegel, HU
机构
[1] Muenster Univ Hosp, Dept Gen Surg, D-48149 Munster, Germany
[2] Ruhr Univ Bochum, Marienhosp, Chirurg Univ Klin, D-4690 Herne, Germany
[3] Univ Munster, Inst Anat, D-4400 Munster, Germany
[4] Inst Text & Verfahrenstech, Denkendorf, Germany
[5] Muenster Univ Hosp, Dept Trauma Hand & Reconstruct Surg, Munster, Germany
关键词
bile duct lesion; biodegradable stent; pigs; surgical technique; vein;
D O I
10.1080/08941930500444560
中图分类号
R61 [外科手术学];
学科分类号
摘要
The incidence of severe bile duct injuries has significantly increased since the introduction of laparoscopic cholecystectomy. The ideal reconstruction procedure for traumatic defects of the bile duct should be technically simple and should preserve both the physiological passage of bile and the sphincter of Oddi. In this article we describe a new technique for bile duct reconstruction in a pig model by means of an autologous vein graft that is splinted by a endoluminal biodegradable polylactate acid stent. In 12 pigs the external jugular vein was removed and used as an autologous vein graft. After performing a median laparotomy a 2-cm segment was resected from the bile duct. The common bile duct was reconstructed by a venous interponate that had been endoluminally stented by a biodegradable polylactate acid stent. For the examination of stent degradation, 2 pigs were sacrificed at 3, 4, and 5 months ( stent degradation group) and the remaining 6 pigs at 6 months ( survival group). All the pigs in the survival group survived for 6 months before being sacrificed. After 4 months the stent material had been completely broken down and the vein graft had been relined with bile duct epithelium. Thus, this new technique for bile duct reconstruction using an autologous vein graft with an endoluminal stent is simple to perform and reliable, and constitutes an interesting alternative to bilodigestive anastomosis due to the preservation of the papilla of Vateri.
引用
收藏
页码:57 / 60
页数:4
相关论文
共 50 条
  • [1] A New Technique for Ureteral Defect Lesion Reconstruction Using an Autologous Vein Graft and a Biodegradable Endoluminal Stent
    Wolters, Heiner H.
    Heistermann, Hans Peter
    Stoeppeler, Sandra
    Hierlemann, Helmut
    Spiegel, Hans-Ullrich
    Palmes, Daniel
    [J]. JOURNAL OF UROLOGY, 2010, 184 (03): : 1197 - 1203
  • [2] Reconstruction of bile duct lesions by an autologous vein graft and a bio-degradable endoluminal stent in an animal model: Technique and clinical impact
    Heistermann, HP
    Palmes, D
    Hierlemann, H
    Ebsen, M
    Horstmann, R
    Hohlbach, G
    Spiegel, HU
    [J]. ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (11): : 952 - 957
  • [3] Repair of Bile Duct Injury With Autologous Vein Graft and Stent
    Xie, Bin
    Luo, Haiping
    Yang, Xinglong
    Zhao, Yanping
    He, Chongwu
    Wan, Xiaobin
    Xu, Zhitao
    Yu, Xingwei
    Liu, Wubo
    Liu, Qiang
    [J]. EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2018, 16 (06) : 696 - 700
  • [4] Technique for the safe placement of a biodegradable stent into the common bile duct of rabbits
    Chen, Yigang
    Yan, Jun
    Wang, Zhigang
    Yu, Song
    Yuan, Ziming
    Wang, Xiaohu
    Zhang, Xiaonong
    Zheng, Qi
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 6 (05) : 1101 - 1104
  • [5] Morphological Changes during Creation of a Neo-Bile Duct Using a Vein and a Biodegradable Endoluminal Stent
    Palmes, Daniel
    Wolters, Heiner
    Spiegel, Hans-Ullrich
    Mueller, Erhard
    Minin, Evgeny
    Heistermann, Hans Peter
    [J]. JOURNAL OF INVESTIGATIVE SURGERY, 2009, 22 (06) : 435 - 444
  • [6] Reconstruction of ureteral defect lesion with vein graft and a biodegradable endoluminal stent: An innovative therapeutic approach
    Kathpalia, Rohit
    Sengottayan, Vengetesh K.
    Goel, Apul
    [J]. INDIAN JOURNAL OF UROLOGY, 2011, 27 (01) : 147 - +
  • [7] Use of an Autologous Vein Graft and Stent in the Repair of Common Bile Defects: An Experimental Study
    Muammer Karaayvaz
    Serdar Uğraş
    Osman Güler
    Metin Aydin
    Ismail Alkan
    Muhammed Furkan Yiğit
    [J]. Surgery Today, 1998, 28 : 830 - 833
  • [8] Use of an autologous vein graft and stent in the repair of common bile defects: An experimental study
    Karaayvaz, M
    Ugras, S
    Guler, O
    Aydin, M
    Alkan, I
    Yigit, MF
    [J]. SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1998, 28 (08): : 830 - 833
  • [9] REPLACEMENT OF COMMON BILE-DUCT BY AN AUTOLOGOUS VEIN
    WITTRIN, G
    CLEMENS, M
    ARNDT, M
    RUHLAND, D
    [J]. RESEARCH IN EXPERIMENTAL MEDICINE, 1978, 173 (01) : 95 - 103
  • [10] EXPERIMENTAL SUBSTITUTION OF THE COMMON BILE DUCT WITH AN AUTOLOGOUS URETERAL GRAFT
    RIEGER, IT
    WAHL, FJ
    HASS, GM