An experimental study on the frosting characteristic and performance of a micro-channel evaporator in an air source heat pump unit

被引:24
|
作者
Hu, Wenju [1 ]
Fan, Jin [1 ]
Song, Mengjie [2 ,3 ,4 ]
Jia, Peng [1 ]
Gao, Yan [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Beijing Key Lab Heating Gas Supply Ventilating &, Beijing 100044, Peoples R China
[2] Beijing Inst Technol, Sch Mech Engn, Dept Energy & Power Engn, Beijing, Peoples R China
[3] Univ Shanghai Sci & Technol, Sch Environm & Architecture, 516 Jungong Rd, Shanghai, Peoples R China
[4] TIPC, CAS Key Lab Cryogen, Beijing, Peoples R China
关键词
Micro-channel heat exchanger; Frosting; Refrigerant distribution; Air source heat pump; COP; 2-PHASE FLOW DISTRIBUTION; REFRIGERANT DISTRIBUTION; PHASE-CHANGE; EXCHANGERS; HEADER; IMPROVEMENT; OPTIMIZATION; TEMPERATURE; CHANNELS; STORAGE;
D O I
10.1016/j.enbuild.2020.110254
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Frosting and refrigerant distribution uneven easily are two key problems restricting the wide application of micro-channel heat exchanger in the field of air source heat pump (ASHP). In this paper, frosting experiments were carried out on two kinds of micro-channel heat exchanger in three cases that with different refrigerant distribution characteristics. Frost and temperature distribution characteristics and their influence on the heat pump's COP and heating capacity was studied. The results show distribution of refrigerant in heat exchanger directly affects the frost and temperature distribution on the surface of micro channel heat exchanger, and affects the heating capacity and COP of ASHP greatly. Vertical placement of flat tubes and horizontal placement of the headers can be beneficial to the refrigerant distribution compared with that with the headers vertically placed. Flow direction of refrigerant in the heat exchanger must be from bottom to top to avoid deteriorated heat transfer performance and instability of ASHP. Difference between the lowest temperature and largest temperature on heat exchanger surface can be used as an index to judge whether ASHP works in high performance state. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Effects of evaporator frosting on the performance of an air-to-air heat pump
    Martínez-Frías, J
    Aceves, SM
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1999, 121 (01): : 60 - 65
  • [2] Experimental investigation on an air source heat pump system with a novel anti-frosting evaporator
    Yu, Shipeng
    Su, Yi
    Cai, Weihua
    Qiu, Guodong
    APPLIED THERMAL ENGINEERING, 2023, 221
  • [3] Study on performance of air source heat pump water heater/chiller unit under frosting
    Yao, Y
    Jiang, YQ
    Ma, ZL
    Deng, SM
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1563 - 1567
  • [4] An experimental study on even frosting performance of an air source heat pump unit with a multi-circuit outdoor coil
    Song Mengjie
    Xia Liang
    Mao Ning
    Deng Shiming
    APPLIED ENERGY, 2016, 164 : 36 - 44
  • [5] An experimental study on energy-storage based defrosting performance of an air source heat pump system with a micro-channel heat exchanger as outdoor coil
    Xu, Zhenjun
    Han, Lu
    APPLIED THERMAL ENGINEERING, 2024, 240
  • [6] Experimental analysis of an air-water heat pump with micro-channel heat exchanger
    Brignoli, Riccardo
    Cecchinato, Luca
    Zilio, Claudio
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1119 - 1130
  • [7] INFLUENCE OF EVAPORATOR FROSTING ON THE PERFORMANCE OF AN OUTDOOR AIR WATER HEAT-PUMP
    DANJOUX, R
    EGEE, M
    BAILLY, A
    POPLIMONT, P
    REVUE GENERALE DE THERMIQUE, 1986, 25 (293): : 289 - 296
  • [8] A study on the performance of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit
    Yao, Y
    Jiang, YQ
    Deng, SM
    Ma, ZL
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (17-18) : 3745 - 3756
  • [9] Development of micro-channel heat exchanger for heat pump outdoor unit
    Oritani, Y., 1600, Japan Light Metal Welding and Construction Assoc. (52):
  • [10] Failure analysis of micro-channel condenser of air source heat pump water heater
    Zhang, Piji
    Dong, Weili
    Wang, Lida
    Sun, Wen
    Liu, Bingyan
    Yang, Zhengqing
    Liu, Guichang
    ENGINEERING FAILURE ANALYSIS, 2021, 122